Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Correlation between retinal oxygen saturation and the haemodynamic parameters of the ophthalmic artery in healthy subjects

M. Král, T. Svrčinová, P. Hok, T. Dorňák, M. Rybáriková, J. Mareš, P. Kaňovský, M. Šín

. 2022 ; 100 (7) : e1489-e1495. [pub] 20220522

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22032925
E-zdroje Online Plný text

NLK Free Medical Journals od 2008 do Před 1 rokem
Medline Complete (EBSCOhost) od 2008-02-01 do Před 1 rokem
Wiley Free Content od 2008 do Před 1 rokem

PURPOSE: The aim of the study was to obtain the values of oxygen saturation in retinal vessels and ophthalmic blood flow parameters in a healthy Caucasian population and assess whether the oximetry parameters are affected by the flow rate or the vascular resistance. METHODS: The spectrophotometric retinal oximetry and colour Doppler imaging (CDI) of retinal vessels were successfully performed with 52 healthy subjects (average age 29.7 ± 5.6 years). The retinal oximeter simultaneously measures the wavelength difference of haemoglobin oxygen saturation in retinal arterioles and venules. The arteriolar and venular saturation in both eyes was measured. The peak systolic (PSV) end diastolic (EDV) velocities, resistive (RI) and pulsatility (PI) indices were obtained for both eyes using CDI in the ophthalmic artery. A paired t-test and two sample t-tests were used for statistical analyses. The correlation was assessed using the Pearson coefficient correlation. RESULTS: The mean oxygen saturation level was 96.9 ± 3.0% for the retinal arterioles and 65.0 ± 5.1% for the retinal venules. The A-V difference was 31.8 ± 4.6%. The mean of the measured haemodynamic parameters was PSV 46.6 ± 9.4 cm/s, EDV 12.0 ± 3.5 cm/s, PI 1.68 ± 0.38 and RI 0.74 ± 0.05. No significant difference in oxygen saturation and haemodynamic parameters was found between the left and the right eyes or the dominant and non-dominant eye. The oximetry and ultrasound values were sex independent. The Pearson correlation coefficient demonstrated a significant yet weak negative correlation between A-V difference and RI (r = -0.321, p = 0.020). CONCLUSIONS: A negative correlation between A-V difference and resistance index was observed, suggesting that reduced oxygen consumption may reflect the increased vascular tone of the ophthalmic vessels, which is likely determined by autoregulatory mechanisms.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22032925
003      
CZ-PrNML
005      
20230131151431.0
007      
ta
008      
230120s2022 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1111/aos.15189 $2 doi
035    __
$a (PubMed)35599335
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Král, Michal $u Department of Neurology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/000000029700677X
245    10
$a Correlation between retinal oxygen saturation and the haemodynamic parameters of the ophthalmic artery in healthy subjects / $c M. Král, T. Svrčinová, P. Hok, T. Dorňák, M. Rybáriková, J. Mareš, P. Kaňovský, M. Šín
520    9_
$a PURPOSE: The aim of the study was to obtain the values of oxygen saturation in retinal vessels and ophthalmic blood flow parameters in a healthy Caucasian population and assess whether the oximetry parameters are affected by the flow rate or the vascular resistance. METHODS: The spectrophotometric retinal oximetry and colour Doppler imaging (CDI) of retinal vessels were successfully performed with 52 healthy subjects (average age 29.7 ± 5.6 years). The retinal oximeter simultaneously measures the wavelength difference of haemoglobin oxygen saturation in retinal arterioles and venules. The arteriolar and venular saturation in both eyes was measured. The peak systolic (PSV) end diastolic (EDV) velocities, resistive (RI) and pulsatility (PI) indices were obtained for both eyes using CDI in the ophthalmic artery. A paired t-test and two sample t-tests were used for statistical analyses. The correlation was assessed using the Pearson coefficient correlation. RESULTS: The mean oxygen saturation level was 96.9 ± 3.0% for the retinal arterioles and 65.0 ± 5.1% for the retinal venules. The A-V difference was 31.8 ± 4.6%. The mean of the measured haemodynamic parameters was PSV 46.6 ± 9.4 cm/s, EDV 12.0 ± 3.5 cm/s, PI 1.68 ± 0.38 and RI 0.74 ± 0.05. No significant difference in oxygen saturation and haemodynamic parameters was found between the left and the right eyes or the dominant and non-dominant eye. The oximetry and ultrasound values were sex independent. The Pearson correlation coefficient demonstrated a significant yet weak negative correlation between A-V difference and RI (r = -0.321, p = 0.020). CONCLUSIONS: A negative correlation between A-V difference and resistance index was observed, suggesting that reduced oxygen consumption may reflect the increased vascular tone of the ophthalmic vessels, which is likely determined by autoregulatory mechanisms.
650    _2
$a dospělí $7 D000328
650    _2
$a rychlost toku krve $7 D001783
650    _2
$a zdraví dobrovolníci pro lékařské studie $7 D064368
650    _2
$a hemodynamika $7 D006439
650    _2
$a hemoglobiny $7 D006454
650    _2
$a lidé $7 D006801
650    12
$a arteria ophthalmica $7 D009880
650    _2
$a oxymetrie $x metody $7 D010092
650    _2
$a kyslík $7 D010100
650    _2
$a saturace kyslíkem $7 D000089382
650    _2
$a retina $7 D012160
650    12
$a arteria centralis retinae $x diagnostické zobrazování $x fyziologie $7 D012161
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Svrčinová, Tereza $u Department of Neurology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/0000000288399073
700    1_
$a Hok, Pavel $u Department of Neurology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/000000031010384X
700    1_
$a Dorňák, Tomáš $u Department of Neurology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/0000000251113617
700    1_
$a Rybáriková, Martina $u Department of Ophthalmology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/0000000267085905
700    1_
$a Mareš, Jan $u Department of Neurology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/0000000347609123
700    1_
$a Kaňovský, Petr $u Department of Neurology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/0000000290093241
700    1_
$a Šín, Martin $u Department of Ophthalmology, University Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic $1 https://orcid.org/0000000250739482
773    0_
$w MED00179743 $t Acta ophthalmologica $x 1755-3768 $g Roč. 100, č. 7 (2022), s. e1489-e1495
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35599335 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230120 $b ABA008
991    __
$a 20230131151427 $b ABA008
999    __
$a ok $b bmc $g 1891593 $s 1184260
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2022 $b 100 $c 7 $d e1489-e1495 $e 20220522 $i 1755-3768 $m Acta ophthalmologica $n Acta Ophthalmol $x MED00179743
LZP    __
$a Pubmed-20230120

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...