Programmable Millifluidic Platform Integrating Automatic Electromembrane Extraction Cleanup and In-Line Electrochemical Detection: A Proof of Concept

A. Sahragard, M. Dvořák, E. J Carrasco-Correa, P. Varanasupakul, P. Kubáň, M. Miró

. 2022 ; 7 (10) : 3161-3168. [pub] 20221005

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22032965

A fully automatic millifluidic sensing platform coupling in-line nonsupported microelectromembrane extraction (μ-EME) with electrochemical detection (ECD) is herein proposed for the first time. Exploiting the features of the second generation of flow analysis, termed sequential injection (SI), the smart integration of SI and μ-EME-ECD enables (i) the repeatable formation of microvolumes of phases for the extraction step in a membrane-less (nonsupported) arrangement, (ii) diverting the acceptor plug to the ECD sensing device, (iii) in-line pH adjustment before the detection step, and (iv) washing of the platform for efficient removal of remnants of wetting film solvent, all entirely unsupervised. The real-life applicability of the miniaturized sensing system is studied for in-line sample cleanup and ECD of diclofenac as a model analyte after μ-EME of urine as a complex biological sample. A comprehensive study of the merits and the limitations of μ-EME solvents on ECD is presented. Under the optimal experimental conditions using 14 μL of unprocessed urine as the donor, 14 μL of 1-nonanol as the organic phase, and 14 μL of 25 mM NaOH as the acceptor in a 2.4 mm ID PTFE tubing, an extraction voltage of 250 V, and an extraction time of 10 min, an absolute (mass) extraction recovery of 48% of diclofenac in urine is obtained. The proposed flow-through system is proven to efficiently remove the interfering effect of predominantly occurring organic species in human urine on ECD with RSD% less than 8.6%.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22032965
003      
CZ-PrNML
005      
20230131151841.0
007      
ta
008      
230120s2022 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1021/acssensors.2c01648 $2 doi
035    __
$a (PubMed)36200176
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Sahragard, Ali $u Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok10330, Thailand
245    10
$a Programmable Millifluidic Platform Integrating Automatic Electromembrane Extraction Cleanup and In-Line Electrochemical Detection: A Proof of Concept / $c A. Sahragard, M. Dvořák, E. J Carrasco-Correa, P. Varanasupakul, P. Kubáň, M. Miró
520    9_
$a A fully automatic millifluidic sensing platform coupling in-line nonsupported microelectromembrane extraction (μ-EME) with electrochemical detection (ECD) is herein proposed for the first time. Exploiting the features of the second generation of flow analysis, termed sequential injection (SI), the smart integration of SI and μ-EME-ECD enables (i) the repeatable formation of microvolumes of phases for the extraction step in a membrane-less (nonsupported) arrangement, (ii) diverting the acceptor plug to the ECD sensing device, (iii) in-line pH adjustment before the detection step, and (iv) washing of the platform for efficient removal of remnants of wetting film solvent, all entirely unsupervised. The real-life applicability of the miniaturized sensing system is studied for in-line sample cleanup and ECD of diclofenac as a model analyte after μ-EME of urine as a complex biological sample. A comprehensive study of the merits and the limitations of μ-EME solvents on ECD is presented. Under the optimal experimental conditions using 14 μL of unprocessed urine as the donor, 14 μL of 1-nonanol as the organic phase, and 14 μL of 25 mM NaOH as the acceptor in a 2.4 mm ID PTFE tubing, an extraction voltage of 250 V, and an extraction time of 10 min, an absolute (mass) extraction recovery of 48% of diclofenac in urine is obtained. The proposed flow-through system is proven to efficiently remove the interfering effect of predominantly occurring organic species in human urine on ECD with RSD% less than 8.6%.
650    _2
$a lidé $7 D006801
650    12
$a diklofenak $7 D004008
650    12
$a membrány umělé $7 D008567
655    _2
$a časopisecké články $7 D016428
700    1_
$a Dvořák, Miloš $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, BrnoCZ-60200, Czech Republic
700    1_
$a J Carrasco-Correa, Enrique $u CLECEM group, Department of Analytical Chemistry, University of Valencia, C/Doctor Moliner 50, Burjassot, Valencia46100, Spain
700    1_
$a Varanasupakul, Pakorn $u Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok10330, Thailand
700    1_
$a Kubáň, Pavel $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, BrnoCZ-60200, Czech Republic $1 https://orcid.org/0000000289289255
700    1_
$a Miró, Manuel $u FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa km 7.5, Palma de Mallorca, Illes BalearsE-07122, Spain $1 https://orcid.org/0000000284133008
773    0_
$w MED00201228 $t ACS sensors $x 2379-3694 $g Roč. 7, č. 10 (2022), s. 3161-3168
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36200176 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230120 $b ABA008
991    __
$a 20230131151837 $b ABA008
999    __
$a ok $b bmc $g 1891623 $s 1184300
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2022 $b 7 $c 10 $d 3161-3168 $e 20221005 $i 2379-3694 $m ACS sensors $n ACS Sens $x MED00201228
LZP    __
$a Pubmed-20230120

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...