Dynamic Ultrasound Examination for Extensor Pollicis Longus Tendon Rupture after Palpation-Guided Corticosteroid Injection

YC. Chen, WT. Wu, K. Mezian, V. Ricci, L. Özçakar, KV. Chang

. 2023 ; 13 (5) : . [pub] 20230303

Status not-indexed Language English Country Switzerland

Document type Journal Article

This report aimed to present a case of wrist-tendon rupture and to discuss a rare complication after corticosteroid injection. A 67-year-old woman had difficulty extending her left-thumb interphalangeal joint several weeks after a palpation-guided local corticosteroid injection. Passive motions remained intact without sensory abnormalities. Ultrasound examination showed hyperechoic tissues at the site of the extensor pollicis longus (EPL) tendon at the wrist level and an atrophic EPL muscle stump at the forearm level. Dynamic imaging demonstrated no motion in the EPL muscle during passive thumb flexion/extension. The diagnosis of complete EPL rupture, possibly due to inadvertent intratendinous corticosteroid injection, was therefore confirmed.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23002763
003      
CZ-PrNML
005      
20230421100058.0
007      
ta
008      
230413s2023 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/diagnostics13050959 $2 doi
035    __
$a (PubMed)36900103
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Chen, Ying-Chun $u Department of Physical Medicine and Rehabilitation, College of Medicine, National Taiwan University, Taipei 10048, Taiwan $1 https://orcid.org/0000000157649706
245    10
$a Dynamic Ultrasound Examination for Extensor Pollicis Longus Tendon Rupture after Palpation-Guided Corticosteroid Injection / $c YC. Chen, WT. Wu, K. Mezian, V. Ricci, L. Özçakar, KV. Chang
520    9_
$a This report aimed to present a case of wrist-tendon rupture and to discuss a rare complication after corticosteroid injection. A 67-year-old woman had difficulty extending her left-thumb interphalangeal joint several weeks after a palpation-guided local corticosteroid injection. Passive motions remained intact without sensory abnormalities. Ultrasound examination showed hyperechoic tissues at the site of the extensor pollicis longus (EPL) tendon at the wrist level and an atrophic EPL muscle stump at the forearm level. Dynamic imaging demonstrated no motion in the EPL muscle during passive thumb flexion/extension. The diagnosis of complete EPL rupture, possibly due to inadvertent intratendinous corticosteroid injection, was therefore confirmed.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Wu, Wei-Ting $u Department of Physical Medicine and Rehabilitation, College of Medicine, National Taiwan University, Taipei 10048, Taiwan $u Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan
700    1_
$a Mezian, Kamal $u Department of Rehabilitation Medicine, Charles University, First Faculty of Medicine and General University Hospital in Prague, 12800 Prague, Czech Republic $1 https://orcid.org/0000000272033325
700    1_
$a Ricci, Vincenzo $u Physical and Rehabilitation Medicine Unit, Luigi Sacco University Hospital, ASST Fatebenefratelli-Sacco, 20157 Milan, Italy $1 https://orcid.org/0000000325762039
700    1_
$a Özçakar, Levent $u Department of Physical and Rehabilitation Medicine, Hacettepe University Medical School, Ankara 06100, Turkey
700    1_
$a Chang, Ke-Vin $u Department of Physical Medicine and Rehabilitation, College of Medicine, National Taiwan University, Taipei 10048, Taiwan $u Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei 10845, Taiwan $u Center for Regional Anesthesia and Pain Medicine, Wang-Fang Hospital, Taipei Medical University, Taipei 11600, Taiwan $1 https://orcid.org/0000000275585651
773    0_
$w MED00195450 $t Diagnostics (Basel, Switzerland) $x 2075-4418 $g Roč. 13, č. 5 (2023)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36900103 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230413 $b ABA008
991    __
$a 20230421100051 $b ABA008
999    __
$a ok $b bmc $g 1922657 $s 1188970
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2023 $b 13 $c 5 $e 20230303 $i 2075-4418 $m Diagnostics $n Diagnostics $x MED00195450
LZP    __
$a Pubmed-20230413

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...