Design and performance of a flow sensor CoroQuant used with emergency lung ventilator CoroVent during COVID-19 pandemic

L. Bís, K. Roubík

. 2022 ; 22 (-) : 100383. [pub] 20220620

Status neindexováno Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc23003382

At the time of COVID-19 pandemic onset in spring 2020 a project CoroVent was initiated with the aim to design and produce emergency lung ventilators and distribute them to hospitals. No flow and tidal volume sensors were available for the project. The lack of tidal volume sensors was a consequence of the rapidly increased demand for mechanical lung ventilators and their consumables. The aim of the study was to develop a special flow sensor CoroQuant for the CoroVent ventilators. The sensor based on pneumotachographic principle, manufactured by the plastic injection moulding of polypropylene, meets the requirements for precision of tidal volume measurement defined by international standard ISO 80601-2-12 for mechanical lung ventilators. CoroVent ventilators with CoroQuant sensors were distributed to 27 hospitals in the Czech Republic for free upon the requests from the medical facilities and started to be clinically used, thus preventing lack of lung ventilators in hospitals in the Czech Republic.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23003382
003      
CZ-PrNML
005      
20230421100155.0
007      
ta
008      
230413s2022 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.measen.2022.100383 $2 doi
035    __
$a (PubMed)36721675
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Bís, Ladislav $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Czechia
245    10
$a Design and performance of a flow sensor CoroQuant used with emergency lung ventilator CoroVent during COVID-19 pandemic / $c L. Bís, K. Roubík
520    9_
$a At the time of COVID-19 pandemic onset in spring 2020 a project CoroVent was initiated with the aim to design and produce emergency lung ventilators and distribute them to hospitals. No flow and tidal volume sensors were available for the project. The lack of tidal volume sensors was a consequence of the rapidly increased demand for mechanical lung ventilators and their consumables. The aim of the study was to develop a special flow sensor CoroQuant for the CoroVent ventilators. The sensor based on pneumotachographic principle, manufactured by the plastic injection moulding of polypropylene, meets the requirements for precision of tidal volume measurement defined by international standard ISO 80601-2-12 for mechanical lung ventilators. CoroVent ventilators with CoroQuant sensors were distributed to 27 hospitals in the Czech Republic for free upon the requests from the medical facilities and started to be clinically used, thus preventing lack of lung ventilators in hospitals in the Czech Republic.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Roubík, Karel $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Czechia
773    0_
$w MED00210745 $t Measurement. Sensors $x 2665-9174 $g Roč. 22, č. - (2022), s. 100383
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36721675 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230413 $b ABA008
991    __
$a 20230421100147 $b ABA008
999    __
$a ok $b bmc $g 1922888 $s 1189589
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2022 $b 22 $c - $d 100383 $e 20220620 $i 2665-9174 $m Measurement. Sensors $n Measur Sens $x MED00210745
LZP    __
$a Pubmed-20230413

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...