Complication rates in rigid vs. flexible endoscopic foreign body removal in children
A. Wiemers, C. Vossen, T. Lücke, N. Freitag, TMTL. Nguyen, L. Möllenberg, P. Pohunek, D. Schramm
Jazyk angličtina Země Irsko
Typ dokumentu časopisecké články
- MeSH
- aspirace do dýchacích cest MeSH
- bronchoskopie metody MeSH
- bronchy MeSH
- cizí tělesa * MeSH
- dítě MeSH
- dýchací soustava MeSH
- endoskopy MeSH
- lidé MeSH
- retrospektivní studie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
While foreign body aspiration remains a frequent and preventable cause of morbidity and mortality in children, recommendations on the appropriate removal technique do often not match the lived practice and expertise of the performing examiners. As there is a scarcity of data regarding success and complication rates of the procedure, the aim of this study was to set up a classification system for procedure-related complications, prospectively record and analyze them. Specialists in the field of foreign body removal contributed cases anonymously. Information regarding procedural details of the bronchoscopy, type, and severity of complications as well as patient characteristics were classified and recorded. Correlations were calculated using Pearson's Chi Square test. A total of 314 rigid and 178 flexible bronchoscopies were compared. Complications were categorized and their severity was defined by the anesthesiologist's assessment of whether to interrupt or terminate the procedure. The overall complication rate was similar in rigid vs. flexible bronchoscopy (19.1% vs. 24.2%, p = 0.232), while respiratory complications occurred significantly less frequent during rigid bronchoscopy (9.2% vs. 16.3%, p = 0.025). This is the largest pediatric case collection recording and comparing complications between rigid and flexible foreign body removal. The higher rate of respiratory complications in flexible bronchoscopy has been shown for the first time and validates some of the concerns about its use for foreign body removal. Flexible bronchoscopy is a safe procedure when extended respiratory monitoring and the possibility of an immediate switch to a secured airway are assured.
Pediatric Department Charles University Prague and University Hospital Motol Prague Czech Republic
Ruhr University Bochum Children's Hospital St Josef Hospital Bochum Germany
Städtische Kliniken Mönchengladbach Elisabeth Krankenhaus Rheydt Germany
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23003930
- 003
- CZ-PrNML
- 005
- 20230425141002.0
- 007
- ta
- 008
- 230418s2023 ie f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ijporl.2023.111474 $2 doi
- 035 __
- $a (PubMed)36753891
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ie
- 100 1_
- $a Wiemers, Anna $u Ruhr University Bochum, Children's Hospital St. Josef-Hospital, Bochum, Germany. Electronic address: anna.wiemers@klinikum-bochum.de
- 245 10
- $a Complication rates in rigid vs. flexible endoscopic foreign body removal in children / $c A. Wiemers, C. Vossen, T. Lücke, N. Freitag, TMTL. Nguyen, L. Möllenberg, P. Pohunek, D. Schramm
- 520 9_
- $a While foreign body aspiration remains a frequent and preventable cause of morbidity and mortality in children, recommendations on the appropriate removal technique do often not match the lived practice and expertise of the performing examiners. As there is a scarcity of data regarding success and complication rates of the procedure, the aim of this study was to set up a classification system for procedure-related complications, prospectively record and analyze them. Specialists in the field of foreign body removal contributed cases anonymously. Information regarding procedural details of the bronchoscopy, type, and severity of complications as well as patient characteristics were classified and recorded. Correlations were calculated using Pearson's Chi Square test. A total of 314 rigid and 178 flexible bronchoscopies were compared. Complications were categorized and their severity was defined by the anesthesiologist's assessment of whether to interrupt or terminate the procedure. The overall complication rate was similar in rigid vs. flexible bronchoscopy (19.1% vs. 24.2%, p = 0.232), while respiratory complications occurred significantly less frequent during rigid bronchoscopy (9.2% vs. 16.3%, p = 0.025). This is the largest pediatric case collection recording and comparing complications between rigid and flexible foreign body removal. The higher rate of respiratory complications in flexible bronchoscopy has been shown for the first time and validates some of the concerns about its use for foreign body removal. Flexible bronchoscopy is a safe procedure when extended respiratory monitoring and the possibility of an immediate switch to a secured airway are assured.
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a cizí tělesa $7 D005547
- 650 _2
- $a bronchoskopie $x metody $7 D001999
- 650 _2
- $a dýchací soustava $7 D012137
- 650 _2
- $a endoskopy $7 D019723
- 650 _2
- $a aspirace do dýchacích cest $7 D053120
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a bronchy $7 D001980
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Vossen, Christina $u Städtische Kliniken Mönchengladbach, Elisabeth Krankenhaus, Rheydt, Germany
- 700 1_
- $a Lücke, Thomas $u Ruhr University Bochum, Children's Hospital St. Josef-Hospital, Bochum, Germany
- 700 1_
- $a Freitag, Nadine $u Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty, University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
- 700 1_
- $a Nguyen, Thi Minh Thao Lea $u Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty, University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
- 700 1_
- $a Möllenberg, Leon $u Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty, University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
- 700 1_
- $a Pohunek, Petr $u Pediatric Department, Charles University Prague and University Hospital Motol, Prague, Czech Republic
- 700 1_
- $a Schramm, Dirk $u Department of General Pediatrics, Neonatology and Pediatric Cardiology, Medical Faculty, University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
- 773 0_
- $w MED00002355 $t International journal of pediatric otorhinolaryngology $x 1872-8464 $g Roč. 166, č. - (2023), s. 111474
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/36753891 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20230418 $b ABA008
- 991 __
- $a 20230425140958 $b ABA008
- 999 __
- $a ok $b bmc $g 1924536 $s 1190139
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 166 $c - $d 111474 $e 20230201 $i 1872-8464 $m International journal of pediatric otorhinolaryngology $n Int J Pediatr Otorhinolaryngol $x MED00002355
- LZP __
- $a Pubmed-20230418