Head-to-Head Comparison of T1 Mapping and Electroanatomical Voltage Mapping in Patients With Ventricular Arrhythmias
M. Sramko, S. Abdel-Kafi, AP. Wijnmaalen, Q. Tao, RJ. van der Geest, HJ. Lamb, K. Zeppenfeld
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- fibróza MeSH
- gadolinium MeSH
- kontrastní látky * MeSH
- lidé MeSH
- magnetická rezonance kinematografická * MeSH
- srdeční arytmie diagnostické zobrazování MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Electroanatomical voltage mapping (EAVM) has been compared with late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR), which cannot delineate diffuse fibrosis. T1-mapping CMR overcomes the limitations of LGE-CMR, but it has not been directly compared against EAVM. OBJECTIVES: This study aims to assess the relationship between left ventricular (LV) endocardial voltage obtained by EAVM and extracellular volume (ECV) obtained by T1 mapping. METHODS: The study investigated patients who underwent endocardial EAVM for ventricular arrhythmias (CARTO 3, Biosense Webster) together with preprocedural contrast-enhanced T1 mapping (Ingenia 3T, Philips Healthcare). After image integration, EAVM datapoints were projected onto LGE-CMR and ECV-encoded images. Average values of unipolar voltage (UV), bipolar voltage (BV), LGE transmurality, and ECV were merged from corresponding cardiac segments (6 per slice) and pooled for analysis. RESULTS: The analysis included data from 628 segments from 18 patients (57 ± 13 years of age, 17% females, LV ejection fraction 48% ± 14%, nonischemic/ischemic cardiomyopathy/controls: 8/6/4 patients). Based on the 95th and 5th percentile values obtained from the controls, ECV >33%, BV <2.9 mV, and UV <6.7 mV were considered abnormal. There was a significant inverse association between voltage and ECV, but only in segments with abnormal ECV. Increased ECV could predict abnormal BV and UV with acceptable accuracy (area under the curve of 0.78 [95% CI: 0.74-0.83] and 0.84 [95% CI: 0.79-0.88]). CONCLUSIONS: This study found a significant inverse relationship between LV endocardial voltage and ECV. Real-time integration of T1 mapping may guide catheter mapping and may allow identification of areas of diffuse fibrosis potentially related to ventricular arrhythmias.
1st Faculty of Medicine Charles University Prague Czech Republic
Department of Cardiology Heart Lung Centre Leiden University Medical Center Leiden the Netherlands
Department of Cardiology Institute for Clinical and Experimental Medicine Prague Czech Republic
Department of Imaging Physics Delft University of Technology Delft the Netherlands
Department of Radiology Leiden University Medical Center Leiden the Netherlands
Willem Einthoven Center for Cardiac Arrhythmia Research and Management Leiden the Netherlands
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23011299
- 003
- CZ-PrNML
- 005
- 20230801132936.0
- 007
- ta
- 008
- 230718s2023 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jacep.2022.10.035 $2 doi
- 035 __
- $a (PubMed)36752459
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Sramko, Marek $u Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic; First Faculty of Medicine, Charles University, Prague, Czech Republic
- 245 10
- $a Head-to-Head Comparison of T1 Mapping and Electroanatomical Voltage Mapping in Patients With Ventricular Arrhythmias / $c M. Sramko, S. Abdel-Kafi, AP. Wijnmaalen, Q. Tao, RJ. van der Geest, HJ. Lamb, K. Zeppenfeld
- 520 9_
- $a BACKGROUND: Electroanatomical voltage mapping (EAVM) has been compared with late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR), which cannot delineate diffuse fibrosis. T1-mapping CMR overcomes the limitations of LGE-CMR, but it has not been directly compared against EAVM. OBJECTIVES: This study aims to assess the relationship between left ventricular (LV) endocardial voltage obtained by EAVM and extracellular volume (ECV) obtained by T1 mapping. METHODS: The study investigated patients who underwent endocardial EAVM for ventricular arrhythmias (CARTO 3, Biosense Webster) together with preprocedural contrast-enhanced T1 mapping (Ingenia 3T, Philips Healthcare). After image integration, EAVM datapoints were projected onto LGE-CMR and ECV-encoded images. Average values of unipolar voltage (UV), bipolar voltage (BV), LGE transmurality, and ECV were merged from corresponding cardiac segments (6 per slice) and pooled for analysis. RESULTS: The analysis included data from 628 segments from 18 patients (57 ± 13 years of age, 17% females, LV ejection fraction 48% ± 14%, nonischemic/ischemic cardiomyopathy/controls: 8/6/4 patients). Based on the 95th and 5th percentile values obtained from the controls, ECV >33%, BV <2.9 mV, and UV <6.7 mV were considered abnormal. There was a significant inverse association between voltage and ECV, but only in segments with abnormal ECV. Increased ECV could predict abnormal BV and UV with acceptable accuracy (area under the curve of 0.78 [95% CI: 0.74-0.83] and 0.84 [95% CI: 0.79-0.88]). CONCLUSIONS: This study found a significant inverse relationship between LV endocardial voltage and ECV. Real-time integration of T1 mapping may guide catheter mapping and may allow identification of areas of diffuse fibrosis potentially related to ventricular arrhythmias.
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a kontrastní látky $7 D003287
- 650 12
- $a magnetická rezonance kinematografická $7 D019028
- 650 _2
- $a gadolinium $7 D005682
- 650 _2
- $a fibróza $7 D005355
- 650 _2
- $a srdeční arytmie $x diagnostické zobrazování $7 D001145
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Abdel-Kafi, Saif $u Willem Einthoven Center for Cardiac Arrhythmia Research and Management (WECAM), Leiden, the Netherlands; Department of Cardiology, Heart-Lung-Centre, Leiden University Medical Center, Leiden, the Netherlands
- 700 1_
- $a Wijnmaalen, Adrianus P $u Willem Einthoven Center for Cardiac Arrhythmia Research and Management (WECAM), Leiden, the Netherlands; Department of Cardiology, Heart-Lung-Centre, Leiden University Medical Center, Leiden, the Netherlands
- 700 1_
- $a Tao, Qian $u Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
- 700 1_
- $a van der Geest, Rob J $u Division of Image Processing (LKEB), Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
- 700 1_
- $a Lamb, Hildo J $u Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
- 700 1_
- $a Zeppenfeld, Katja $u Willem Einthoven Center for Cardiac Arrhythmia Research and Management (WECAM), Leiden, the Netherlands; Department of Cardiology, Heart-Lung-Centre, Leiden University Medical Center, Leiden, the Netherlands. Electronic address: k.zeppenfeld@lumc.nl
- 773 0_
- $w MED00193518 $t JACC. Clinical electrophysiology $x 2405-5018 $g Roč. 9, č. 6 (2023), s. 740-748
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/36752459 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20230718 $b ABA008
- 991 __
- $a 20230801132933 $b ABA008
- 999 __
- $a ok $b bmc $g 1963602 $s 1197564
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 9 $c 6 $d 740-748 $e 20230118 $i 2405-5018 $m JACC. Clinical electrophysiology $n JACC Clin Electrophysiol $x MED00193518
- LZP __
- $a Pubmed-20230718