Visual and Refractive Outcomes After Bilateral Implantation of a Biconvex Aspheric Toric Monofocal Intraocular with a Double C-Loop Haptic Design

RET. Ang, P. Tañá-Rivero, F. Pastor-Pascual, P. Stodulka, M. Tetz, I. Fischinger

. 2023 ; 17 (-) : 2765-2776. [pub] 20230920

Status neindexováno Jazyk angličtina Země Nový Zéland

Typ dokumentu kazuistiky, klinické zkoušky

Perzistentní odkaz   https://www.medvik.cz/link/bmc23015244

PURPOSE: To show the visual and refractive outcomes in cataract patients with corneal astigmatism when bilaterally implanted with a biconvex aspheric toric monofocal intraocular lens (IOL) with a double C-loop haptic-design. METHODS: Forty-seven cataract patients (94 eyes) with corneal astigmatism (≥0.75D) were implanted with the monofocal PODEYE toric IOL and assessed for 4-6 months post-surgery. Measurements included monocular and binocular uncorrected-distance visual acuity (UDVA) and corrected-distance visual acuity (CDVA), under both photopic and mesopic lighting conditions. Refraction, photopic and mesopic contrast sensitivity (with and without glare), and rotational stability were also recorded at the last postoperative visit. RESULTS: At 4-6 months, 78.2% and 98.9% of eyes were within ±0.50D and ±1.00D of the target refraction, respectively. The mean spherical equivalent and refractive cylinder values were 0.09±0.35D and -0.36±0.35D, respectively. 76.5% and 98.8% of eyes presented a postoperative refractive cylinder of ≤0.50D and ≤1.00D, respectively. 91.5% and 100% of patients had a binocular UDVA and CDVA of ≥20/25, respectively. The mean binocular UDVA and CDVA were 0.02±0.08 and -0.02±0.07 logMAR, respectively. Under mesopic conditions, 78.7% and 83.0% of patients presented a binocular UDVA and CDVA ≥20/32, respectively. The mean binocular UDVA and CDVA were 0.15±0.11 and 0.12±0.11 logMAR, respectively. The patients showed good contrast sensitivity under photopic and mesopic conditions. The mean absolute IOL rotation was 1.22±2.21 degrees with 97.87% of eyes having a rotation of <10 degrees. CONCLUSION: This study shows good visual and refractive outcomes for the PODEYE toric IOL when implanted bilaterally in cataract patients with corneal astigmatism.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23015244
003      
CZ-PrNML
005      
20231020093439.0
007      
ta
008      
231010s2023 nz f 000 0|eng||
009      
AR
024    7_
$a 10.2147/OPTH.S432598 $2 doi
035    __
$a (PubMed)37750099
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a nz
100    1_
$a Ang, Robert Edward T $u Cataract and Refractive Surgery Department, Asian Eye Institute, Makati City, Philippines $1 https://orcid.org/0000000250352923
245    10
$a Visual and Refractive Outcomes After Bilateral Implantation of a Biconvex Aspheric Toric Monofocal Intraocular with a Double C-Loop Haptic Design / $c RET. Ang, P. Tañá-Rivero, F. Pastor-Pascual, P. Stodulka, M. Tetz, I. Fischinger
520    9_
$a PURPOSE: To show the visual and refractive outcomes in cataract patients with corneal astigmatism when bilaterally implanted with a biconvex aspheric toric monofocal intraocular lens (IOL) with a double C-loop haptic-design. METHODS: Forty-seven cataract patients (94 eyes) with corneal astigmatism (≥0.75D) were implanted with the monofocal PODEYE toric IOL and assessed for 4-6 months post-surgery. Measurements included monocular and binocular uncorrected-distance visual acuity (UDVA) and corrected-distance visual acuity (CDVA), under both photopic and mesopic lighting conditions. Refraction, photopic and mesopic contrast sensitivity (with and without glare), and rotational stability were also recorded at the last postoperative visit. RESULTS: At 4-6 months, 78.2% and 98.9% of eyes were within ±0.50D and ±1.00D of the target refraction, respectively. The mean spherical equivalent and refractive cylinder values were 0.09±0.35D and -0.36±0.35D, respectively. 76.5% and 98.8% of eyes presented a postoperative refractive cylinder of ≤0.50D and ≤1.00D, respectively. 91.5% and 100% of patients had a binocular UDVA and CDVA of ≥20/25, respectively. The mean binocular UDVA and CDVA were 0.02±0.08 and -0.02±0.07 logMAR, respectively. Under mesopic conditions, 78.7% and 83.0% of patients presented a binocular UDVA and CDVA ≥20/32, respectively. The mean binocular UDVA and CDVA were 0.15±0.11 and 0.12±0.11 logMAR, respectively. The patients showed good contrast sensitivity under photopic and mesopic conditions. The mean absolute IOL rotation was 1.22±2.21 degrees with 97.87% of eyes having a rotation of <10 degrees. CONCLUSION: This study shows good visual and refractive outcomes for the PODEYE toric IOL when implanted bilaterally in cataract patients with corneal astigmatism.
590    __
$a NEINDEXOVÁNO
655    _2
$a kazuistiky $7 D002363
655    _2
$a klinické zkoušky $7 D016430
700    1_
$a Tañá-Rivero, Pedro $u Cataract and Refractive Surgery Department, Oftalvist, Alicante, Spain
700    1_
$a Pastor-Pascual, Francisco $u Cataract and Refractive Surgery Department, Oftalvist, Valencia, Spain
700    1_
$a Stodulka, Pavel $u Cataract and Refractive Surgery Department, Gemini Eye Clinic, Zlin, Czech Republic $1 https://orcid.org/000000023213640X
700    1_
$a Tetz, Manfred $u Cataract and Refractive Surgery Department, Augentagesklinik Spreebogen, Berlin, Germany
700    1_
$a Fischinger, Isaak $u Medical Faculty, Johannes Kepler University Linz, Linz, Austria
773    0_
$w MED00165196 $t Clinical ophthalmology (Auckland, N.Z.) $x 1177-5467 $g Roč. 17, č. - (2023), s. 2765-2776
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37750099 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20231010 $b ABA008
991    __
$a 20231020093433 $b ABA008
999    __
$a ok $b bmc $g 1997064 $s 1201606
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2023 $b 17 $c - $d 2765-2776 $e 20230920 $i 1177-5467 $m Clinical ophthalmology $n Clin Ophthalmol $x MED00165196
LZP    __
$a Pubmed-20231010

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...