Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Epidermal Growth Factor Receptor T790M Mutation Testing in Non-Small Cell Lung Cancer: An International Collaborative Study to Assess Molecular EGFR T790M Testing in Liquid Biopsy

M. Filipits, V. Kainz, V. Sebek, H. Zach, . On Behalf Of The Liquid Biopsy Collaborative Study Group

. 2023 ; 15 (13) : . [pub] 20230707

Status neindexováno Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc23015765

Grantová podpora
Boehringer Ingelheim RCV GmbH & Co KG

BACKGROUND: The detection of the EGFR T790M (T790M) mutation in non-small cell lung cancer (NSCLC) patients who progressed under treatment with first- or second-generation EGFR-tyrosine kinase inhibitors (TKIs) is important to offer a subsequent therapy with a third-generation EGFR-TKI. Liquid biopsy is a powerful tool to determine the T790M mutation status. Several liquid biopsy platforms with varying degrees of accuracy are available to test for T790M mutations, and sensitivities may differ among these methods. METHODS: As no standard exists for the testing of T790M mutation in liquid biopsy, we performed a collaborative study to describe and compare the sensitivity of different in-house liquid biopsy platforms for the detection of the T790M mutation, EGFR exon 19 deletion (del19) and EGFR L858R mutation (L858R) across multiple participating laboratories in seven Central and Eastern European countries. RESULTS: Of the 25 invited laboratories across Central and Eastern Europe, 21 centers participated and received 10 plasma samples spiked with cell-line DNA containing the T790M, del19, or L858R mutation in different concentrations. In-house PCR-based and NGS-based methods were used accordingly, and results were reported as in routine clinical practice. Two laboratories, which used the AmoyDx® EGFR 29 Mutations Detection Kit (AmoyDx) with Cobas® cfDNA Sample Preparation Kit and QX200 Droplet Digital PCR (ddPCR) with the QIAamp Circulating Nucleic Acid Kit identified all ten samples correctly. Cobas® EGFR Mutation Test v2 (Cobas), the NGS methods, and the IdyllaTM detection method used in this study performed within the known sensitivity range of each detection method. CONCLUSIONS: If a negative result was obtained from methods with lower sensitivity (e.g., Cobas), repeated liquid biopsy testing and/or tissue biopsy analysis should be performed whenever possible, to identify T790M-positive patients to allow them to receive the optimal second-line treatment with a third-generation EGFR TKI.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23015765
003      
CZ-PrNML
005      
20231020093444.0
007      
ta
008      
231010s2023 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/cancers15133528 $2 doi
035    __
$a (PubMed)37444638
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Filipits, Martin $u Center for Cancer Research, Medical University of Vienna, 1090 Vienna, Austria $1 https://orcid.org/0000000328474534
245    10
$a Epidermal Growth Factor Receptor T790M Mutation Testing in Non-Small Cell Lung Cancer: An International Collaborative Study to Assess Molecular EGFR T790M Testing in Liquid Biopsy / $c M. Filipits, V. Kainz, V. Sebek, H. Zach, . On Behalf Of The Liquid Biopsy Collaborative Study Group
520    9_
$a BACKGROUND: The detection of the EGFR T790M (T790M) mutation in non-small cell lung cancer (NSCLC) patients who progressed under treatment with first- or second-generation EGFR-tyrosine kinase inhibitors (TKIs) is important to offer a subsequent therapy with a third-generation EGFR-TKI. Liquid biopsy is a powerful tool to determine the T790M mutation status. Several liquid biopsy platforms with varying degrees of accuracy are available to test for T790M mutations, and sensitivities may differ among these methods. METHODS: As no standard exists for the testing of T790M mutation in liquid biopsy, we performed a collaborative study to describe and compare the sensitivity of different in-house liquid biopsy platforms for the detection of the T790M mutation, EGFR exon 19 deletion (del19) and EGFR L858R mutation (L858R) across multiple participating laboratories in seven Central and Eastern European countries. RESULTS: Of the 25 invited laboratories across Central and Eastern Europe, 21 centers participated and received 10 plasma samples spiked with cell-line DNA containing the T790M, del19, or L858R mutation in different concentrations. In-house PCR-based and NGS-based methods were used accordingly, and results were reported as in routine clinical practice. Two laboratories, which used the AmoyDx® EGFR 29 Mutations Detection Kit (AmoyDx) with Cobas® cfDNA Sample Preparation Kit and QX200 Droplet Digital PCR (ddPCR) with the QIAamp Circulating Nucleic Acid Kit identified all ten samples correctly. Cobas® EGFR Mutation Test v2 (Cobas), the NGS methods, and the IdyllaTM detection method used in this study performed within the known sensitivity range of each detection method. CONCLUSIONS: If a negative result was obtained from methods with lower sensitivity (e.g., Cobas), repeated liquid biopsy testing and/or tissue biopsy analysis should be performed whenever possible, to identify T790M-positive patients to allow them to receive the optimal second-line treatment with a third-generation EGFR TKI.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kainz, Verena $u Division of Transplantation, Department of General Surgery, Medical University Vienna, 1090 Vienna, Austria $1 https://orcid.org/0000000268050077
700    1_
$a Sebek, Viktor $u Department of Pharmacology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska st. 976/3, 779 00 Olomouc, Czech Republic
700    1_
$a Zach, Herwig $u Boehringer Ingelheim RCV GmbH & Co KG, 1120 Vienna, Austria $1 https://orcid.org/0009000062153860
700    1_
$a On Behalf Of The Liquid Biopsy Collaborative Study Group,
773    0_
$w MED00173178 $t Cancers $x 2072-6694 $g Roč. 15, č. 13 (2023)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/37444638 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20231010 $b ABA008
991    __
$a 20231020093438 $b ABA008
999    __
$a ok $b bmc $g 1997255 $s 1202127
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2023 $b 15 $c 13 $e 20230707 $i 2072-6694 $m Cancers $n Cancers $x MED00173178
GRA    __
$p Boehringer Ingelheim RCV GmbH & Co KG
LZP    __
$a Pubmed-20231010

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...