Reconstruction with a double-constrained implant design after complex shoulder extra-articular resection
J. Lesensky, AC. Belzarena, M. Daniel
Language English Country England, Great Britain
Document type Journal Article
NLK
BioMedCentral
from 2003-12-01
BioMedCentral Open Access
from 2003
Directory of Open Access Journals
from 2003
Free Medical Journals
from 2003
PubMed Central
from 2003
ProQuest Central
from 2009-01-01
Open Access Digital Library
from 2003-01-01
Open Access Digital Library
from 2003-02-01
Open Access Digital Library
from 2003-01-01
Health & Medicine (ProQuest)
from 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2003
Springer Nature OA/Free Journals
from 2003-12-01
- MeSH
- Humerus MeSH
- Humans MeSH
- Scapula MeSH
- Postoperative Complications etiology MeSH
- Shoulder Joint * surgery MeSH
- Shoulder MeSH
- Plastic Surgery Procedures * MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
BACKGROUND: Approximately, one-third of patients with tumors of proximal humerus will require an extra-articular resection to achieve oncologic margins. This procedure yields poor functional outcomes with a considerable rate of revisions. Unconstrained implants are prone to instability hindering also function of the elbow and hand, whereas constrained shoulder reconstructions suffer from early aseptic loosening of the glenoid component due to bone overload. The purpose of this study was to develop a constrained implant suitable for extra-articular resection with loss of function in deltoid and rotator cuff, which would provide both stability and passive motion, whilst also decreasing the risk of aseptic loosening of the glenoid component. METHODS: In cooperation with Czech Technical University in Prague, we devised an implant consisting of two constrained joints in series connected by a dumbbell piece. The biomechanical analysis showed a reduction of load transfer to the glenoid component with a torque of 8.6 Nm capable of generating an 865-N pulling force on bone screw to just 0.07 Nm, hence shielding the glenoid component from undesired forces and decreasing the risk of aseptic loosening. Three patients with extra-articular resection with a total loss of function of both rotator cuff and deltoid muscle received this type of reconstruction. The average follow-up was 16 months. RESULTS: The surgical technique is straightforward. The surgery took 175 min on average with average blood loss of 516 ml. There were no surgical- or implant-related complications. All three patients were pain-free and had a stable shoulder joint after the reconstruction. All had fully functional elbow, wrist, and hand joints. The average Musculoskeletal Tumor Society (MSTS) score was 21/30 (70%). All patients were pleased with the results. CONCLUSION: The presented innovative implant design has demonstrated to be a promising alternative for reconstruction in these challenging cases.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23016219
- 003
- CZ-PrNML
- 005
- 20231026110148.0
- 007
- ta
- 008
- 231013s2023 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s12957-023-03173-9 $2 doi
- 035 __
- $a (PubMed)37723520
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Lesensky, Jan $u Department of Orthopaedics, First Medical Faculty, University Hospital Na Bulovce, Charles University, Prague, Czech Republic. janless@gmail.com
- 245 10
- $a Reconstruction with a double-constrained implant design after complex shoulder extra-articular resection / $c J. Lesensky, AC. Belzarena, M. Daniel
- 520 9_
- $a BACKGROUND: Approximately, one-third of patients with tumors of proximal humerus will require an extra-articular resection to achieve oncologic margins. This procedure yields poor functional outcomes with a considerable rate of revisions. Unconstrained implants are prone to instability hindering also function of the elbow and hand, whereas constrained shoulder reconstructions suffer from early aseptic loosening of the glenoid component due to bone overload. The purpose of this study was to develop a constrained implant suitable for extra-articular resection with loss of function in deltoid and rotator cuff, which would provide both stability and passive motion, whilst also decreasing the risk of aseptic loosening of the glenoid component. METHODS: In cooperation with Czech Technical University in Prague, we devised an implant consisting of two constrained joints in series connected by a dumbbell piece. The biomechanical analysis showed a reduction of load transfer to the glenoid component with a torque of 8.6 Nm capable of generating an 865-N pulling force on bone screw to just 0.07 Nm, hence shielding the glenoid component from undesired forces and decreasing the risk of aseptic loosening. Three patients with extra-articular resection with a total loss of function of both rotator cuff and deltoid muscle received this type of reconstruction. The average follow-up was 16 months. RESULTS: The surgical technique is straightforward. The surgery took 175 min on average with average blood loss of 516 ml. There were no surgical- or implant-related complications. All three patients were pain-free and had a stable shoulder joint after the reconstruction. All had fully functional elbow, wrist, and hand joints. The average Musculoskeletal Tumor Society (MSTS) score was 21/30 (70%). All patients were pleased with the results. CONCLUSION: The presented innovative implant design has demonstrated to be a promising alternative for reconstruction in these challenging cases.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a rameno $7 D012782
- 650 _2
- $a lopatka $7 D012540
- 650 12
- $a zákroky plastické chirurgie $7 D019651
- 650 12
- $a ramenní kloub $x chirurgie $7 D012785
- 650 _2
- $a humerus $7 D006811
- 650 _2
- $a pooperační komplikace $x etiologie $7 D011183
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Belzarena, Ana C $u Department of Orthopedic Surgery, University of Missouri, Columbia, USA
- 700 1_
- $a Daniel, Matej $u Department of Mechanics, Biomechanics, and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Prague, Czech Republic
- 773 0_
- $w MED00008253 $t World journal of surgical oncology $x 1477-7819 $g Roč. 21, č. 1 (2023), s. 295
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37723520 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20231013 $b ABA008
- 991 __
- $a 20231026110142 $b ABA008
- 999 __
- $a ok $b bmc $g 2000003 $s 1202581
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 21 $c 1 $d 295 $e 20230918 $i 1477-7819 $m World journal of surgical oncology $n World J Surg Oncol $x MED00008253
- LZP __
- $a Pubmed-20231013