Entropy in scalp EEG can be used as a preimplantation marker for VNS efficacy
B. Sklenarova, J. Chladek, M. Macek, M. Brazdil, J. Chrastina, T. Jurkova, P. Burilova, F. Plesinger, E. Zatloukalova, I. Dolezalova
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2011
Free Medical Journals
od 2011
Nature Open Access
od 2011-12-01
PubMed Central
od 2011
Europe PubMed Central
od 2011
ProQuest Central
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Health & Medicine (ProQuest)
od 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2011
Springer Nature OA/Free Journals
od 2011-12-01
- MeSH
- elektroencefalografie MeSH
- entropie MeSH
- hyperventilace MeSH
- lidé MeSH
- nervus vagus MeSH
- refrakterní epilepsie * terapie MeSH
- skalp MeSH
- vagová stimulace * metody MeSH
- výsledek terapie MeSH
- záchvaty MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Vagus nerve stimulation (VNS) is a therapeutic option in drug-resistant epilepsy. VNS leads to ≥ 50% seizure reduction in 50 to 60% of patients, termed "responders". The remaining 40 to 50% of patients, "non-responders", exhibit seizure reduction < 50%. Our work aims to differentiate between these two patient groups in preimplantation EEG analysis by employing several Entropy methods. We identified 59 drug-resistant epilepsy patients treated with VNS. We established their response to VNS in terms of responders and non-responders. A preimplantation EEG with eyes open/closed, photic stimulation, and hyperventilation was found for each patient. The EEG was segmented into eight time intervals within four standard frequency bands. In all, 32 EEG segments were obtained. Seven Entropy methods were calculated for all segments. Subsequently, VNS responders and non-responders were compared using individual Entropy methods. VNS responders and non-responders differed significantly in all Entropy methods except Approximate Entropy. Spectral Entropy revealed the highest number of EEG segments differentiating between responders and non-responders. The most useful frequency band distinguishing responders and non-responders was the alpha frequency, and the most helpful time interval was hyperventilation and rest 4 (the end of EEG recording).
Department of Health Sciences Faculty of Medicine Masaryk University Brno Czech Republic
Institute of Biostatistics and Analyses Faculty of Medicine Masaryk University Brno Czech Republic
Institute of Scientific Instruments Czech Academy of Sciences Brno Czech Republic
International Clinical Research Center St Anne's University Hospital Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24000781
- 003
- CZ-PrNML
- 005
- 20240213093354.0
- 007
- ta
- 008
- 240109s2023 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-023-46113-z $2 doi
- 035 __
- $a (PubMed)37914788
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Sklenarova, B $u Brno Epilepsy Center, First Department of Neurology, Member of ERN-Epicar, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Pekařská 53, 602 00, Brno, Czech Republic $u International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
- 245 10
- $a Entropy in scalp EEG can be used as a preimplantation marker for VNS efficacy / $c B. Sklenarova, J. Chladek, M. Macek, M. Brazdil, J. Chrastina, T. Jurkova, P. Burilova, F. Plesinger, E. Zatloukalova, I. Dolezalova
- 520 9_
- $a Vagus nerve stimulation (VNS) is a therapeutic option in drug-resistant epilepsy. VNS leads to ≥ 50% seizure reduction in 50 to 60% of patients, termed "responders". The remaining 40 to 50% of patients, "non-responders", exhibit seizure reduction < 50%. Our work aims to differentiate between these two patient groups in preimplantation EEG analysis by employing several Entropy methods. We identified 59 drug-resistant epilepsy patients treated with VNS. We established their response to VNS in terms of responders and non-responders. A preimplantation EEG with eyes open/closed, photic stimulation, and hyperventilation was found for each patient. The EEG was segmented into eight time intervals within four standard frequency bands. In all, 32 EEG segments were obtained. Seven Entropy methods were calculated for all segments. Subsequently, VNS responders and non-responders were compared using individual Entropy methods. VNS responders and non-responders differed significantly in all Entropy methods except Approximate Entropy. Spectral Entropy revealed the highest number of EEG segments differentiating between responders and non-responders. The most useful frequency band distinguishing responders and non-responders was the alpha frequency, and the most helpful time interval was hyperventilation and rest 4 (the end of EEG recording).
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a výsledek terapie $7 D016896
- 650 12
- $a vagová stimulace $x metody $7 D055536
- 650 _2
- $a entropie $7 D019277
- 650 _2
- $a skalp $7 D012535
- 650 _2
- $a hyperventilace $7 D006985
- 650 _2
- $a elektroencefalografie $7 D004569
- 650 _2
- $a záchvaty $7 D012640
- 650 12
- $a refrakterní epilepsie $x terapie $7 D000069279
- 650 _2
- $a nervus vagus $7 D014630
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Chladek, J $u Brno Epilepsy Center, First Department of Neurology, Member of ERN-Epicar, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Pekařská 53, 602 00, Brno, Czech Republic $u Institute of Scientific Instruments, Czech Academy of Sciences, Brno, Czech Republic $u Behavioral and Social Neuroscience Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Macek, M $u Institute of Scientific Instruments, Czech Academy of Sciences, Brno, Czech Republic
- 700 1_
- $a Brazdil, M $u Brno Epilepsy Center, First Department of Neurology, Member of ERN-Epicar, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Pekařská 53, 602 00, Brno, Czech Republic $u Behavioral and Social Neuroscience Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Chrastina, J $u Brno Epilepsy Center, Department of Neurosurgery, St. Anne's University Hospital and Masaryk University, Brno, Czech Republic
- 700 1_
- $a Jurkova, T $u Institute of Biostatistics and Analyses, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Burilova, P $u Department of Health Sciences, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Plesinger, F $u Institute of Scientific Instruments, Czech Academy of Sciences, Brno, Czech Republic
- 700 1_
- $a Zatloukalova, E $u Brno Epilepsy Center, First Department of Neurology, Member of ERN-Epicar, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Pekařská 53, 602 00, Brno, Czech Republic $u International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
- 700 1_
- $a Dolezalova, I $u Brno Epilepsy Center, First Department of Neurology, Member of ERN-Epicar, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Pekařská 53, 602 00, Brno, Czech Republic. Irena.dolezalova@fnusa.cz $u International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic. Irena.dolezalova@fnusa.cz
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 13, č. 1 (2023), s. 18849
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37914788 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240109 $b ABA008
- 991 __
- $a 20240213093351 $b ABA008
- 999 __
- $a ok $b bmc $g 2049414 $s 1210475
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 13 $c 1 $d 18849 $e 20231101 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20240109