Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

False aneurysms of the thoracic aorta: anastomosis investigation using the inflation-extension test

S. Recicarova, H. Chlup, M. Jonak, I. Netuka

. 2023 ; 21 (4) : 174-179. [pub] 20231213

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24002966

Grantová podpora
IN 00023001 Ministry of Health, Czech Republic - Czech Republic

INTRODUCTION: False aneurysms in the thoracic aorta are dangerous complications that can occur after cardiac surgery. They often result in high mortality rates. These aneurysms are caused by damage to all layers of the aortic wall. This study aimed to pinpoint the area of the experimental specimen (native vessel, anastomosis, or prosthetic graft) with the greatest deformation, to determine whether a false aneurysm is likely to develop in the anastomotic portion. METHODS: We conducted the inflation-extension test by performing eight cycles ranging from 0 to 20. The pressure sampling frequency was 100 Hz, and each cycle lasted approximately 34 seconds, resulting in a loading frequency of 0.03 Hz. During the experiment, each camera captured 3,000 frames. Based on the data collected, we evaluated and compared the loading stages of cycle 1 and cycle 8. RESULTS AND DISCUSSION: During loading, the native vessel experienced a dominant deformation of approximately 7% in the circumferential direction. The prosthetic graft, which had a longitudinal construction, deformed by approximately 8% in the axial direction. The prosthetic graft, on the other hand, only experienced a deformation of up to 1.5% in the circumferential direction, which was about 5 times smaller than the deformation of the native vessel. The anastomosis area was very stiff and showed minimal deformation. Additionally, there was little difference in the mechanical response between the first C1 and the eighth C8 cycle. CONCLUSION: Based on the available evidence, it can be inferred that aortic false aneurysms are more likely to form just behind the suture lines in the native aorta, which is more elastic compared to stiff sections of anastomosis and prosthetic graft. Numerous pulsations of the native vessel will likely cause the impairment of the aorta at the margin of the anastomosis. This will lead to disruption of the aortic wall and false aneurysm formation in the native vessel near the area of anastomosis.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24002966
003      
CZ-PrNML
005      
20250312094525.0
007      
ta
008      
240215s2023 xr ado f 000 0|eng||
009      
AR
024    7_
$a 10.32725/jab.2023.023 $2 doi
035    __
$a (PubMed)38112456
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Rečičárová, Sandra $u Institute for Clinical and Experimental Medicine (IKEM), Department of Cardiovascular Surgery, Prague, Czech Republic $u Charles University, First Faculty of Medicine, Prague, Czech Republic $7 xx0283568
245    10
$a False aneurysms of the thoracic aorta: anastomosis investigation using the inflation-extension test / $c S. Recicarova, H. Chlup, M. Jonak, I. Netuka
520    9_
$a INTRODUCTION: False aneurysms in the thoracic aorta are dangerous complications that can occur after cardiac surgery. They often result in high mortality rates. These aneurysms are caused by damage to all layers of the aortic wall. This study aimed to pinpoint the area of the experimental specimen (native vessel, anastomosis, or prosthetic graft) with the greatest deformation, to determine whether a false aneurysm is likely to develop in the anastomotic portion. METHODS: We conducted the inflation-extension test by performing eight cycles ranging from 0 to 20. The pressure sampling frequency was 100 Hz, and each cycle lasted approximately 34 seconds, resulting in a loading frequency of 0.03 Hz. During the experiment, each camera captured 3,000 frames. Based on the data collected, we evaluated and compared the loading stages of cycle 1 and cycle 8. RESULTS AND DISCUSSION: During loading, the native vessel experienced a dominant deformation of approximately 7% in the circumferential direction. The prosthetic graft, which had a longitudinal construction, deformed by approximately 8% in the axial direction. The prosthetic graft, on the other hand, only experienced a deformation of up to 1.5% in the circumferential direction, which was about 5 times smaller than the deformation of the native vessel. The anastomosis area was very stiff and showed minimal deformation. Additionally, there was little difference in the mechanical response between the first C1 and the eighth C8 cycle. CONCLUSION: Based on the available evidence, it can be inferred that aortic false aneurysms are more likely to form just behind the suture lines in the native aorta, which is more elastic compared to stiff sections of anastomosis and prosthetic graft. Numerous pulsations of the native vessel will likely cause the impairment of the aorta at the margin of the anastomosis. This will lead to disruption of the aortic wall and false aneurysm formation in the native vessel near the area of anastomosis.
650    _2
$a lidé $7 D006801
650    _2
$a aorta thoracica $x chirurgie $7 D001013
650    12
$a nepravé aneurysma $x diagnóza $x etiologie $x chirurgie $7 D017541
650    12
$a aortální aneurysma $x komplikace $7 D001014
650    _2
$a anastomóza chirurgická $x škodlivé účinky $7 D000714
655    _2
$a časopisecké články $7 D016428
700    1_
$a Chlup, Hynek $u Czech Technical University, Faculty of Mechanical Engineering, Laboratory of Cardiovascular Biomechanics, Prague, Czech Republic $7 xx0210944
700    1_
$a Jonák, Michael, $d 1971- $u Institute for Clinical and Experimental Medicine (IKEM), Department of Cardiovascular Surgery, Prague, Czech Republic $7 xx0101782
700    1_
$a Netuka, Ivan, $d 1973- $u Institute for Clinical and Experimental Medicine (IKEM), Department of Cardiovascular Surgery, Prague, Czech Republic $7 xx0074183
773    0_
$w MED00012667 $t Journal of applied biomedicine $x 1214-0287 $g Roč. 21, č. 4 (2023), s. 174-179
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38112456 $y Pubmed
910    __
$a ABA008 $b B 2301 $c 1249 $y p $z 0
990    __
$a 20240215 $b ABA008
991    __
$a 20250312094532 $b ABA008
999    __
$a ok $b bmc $g 2283467 $s 1212702
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 21 $c 4 $d 174-179 $e 20231213 $i 1214-0287 $m Journal of applied biomedicine $n J Appl Biomed $x MED00012667
GRA    __
$a IN 00023001 $p Ministry of Health, Czech Republic $2 Czech Republic
LZP    __
$b NLK124 $a Pubmed-20240215

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...