Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T

J. Vymazal, Z. Ryznarova, AM. Rulseh

. 2024 ; 15 (1) : 73. [pub] 20240314

Status neindexováno Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24005591

Grantová podpora
IG204301 Ministerstvo Zdravotnictví Ceské Republiky
IG204302 Ministerstvo Zdravotnictví Ceské Republiky
IG204303 Ministerstvo Zdravotnictví Ceské Republiky

OBJECTIVES: Accurate detection of metastatic brain lesions (MBL) is critical due to advances in radiosurgery. We compared the results of three readers in detecting MBL using T1-weighted 2D spin echo (SE) and sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) sequences with whole-brain coverage at both 1.5 T and 3 T. METHODS: Fifty-six patients evaluated for MBL were included and underwent a standard protocol (1.5 T, n = 37; 3 T, n = 19), including postcontrast T1-weighted SE and SPACE. The rating was performed by three raters in two sessions > six weeks apart. The true number of MBL was determined using all available imaging including follow-up. Intraclass correlations for intra-rater and inter-rater agreement were calculated. Signal intensity ratios (SIR; enhancing lesion, white matter) were determined on a subset of 46 MBL > 4 mm. A paired t-test was used to evaluate postcontrast sequence order and SIR. Reader accuracy was evaluated by the coefficient of determination. RESULTS: A total of 135 MBL were identified (mean/subject 2.41, SD 6.4). The intra-rater agreement was excellent for all 3 raters (ICC = 0.97-0.992), as was the inter-rater agreement (ICC = 0.995 SE, 0.99 SPACE). Subjective qualitative ratings were lower for SE images; however, signal intensity ratios were higher in SE sequences. Accuracy was high in all readers for both SE (R2 0.95-0.96) and SPACE (R2 0.91-0.96) sequences. CONCLUSIONS: Although SE sequences are superior to gradient echo sequences in the detection of small MBL, they have long acquisition times and frequent artifacts. We show that T1-weighted SPACE is not inferior to standard thin-slice SE sequences in the detection of MBL at both imaging fields. CRITICAL RELEVANCE STATEMENT: Our results show the suitability of 3D T1-weighted turbo spin echo (TSE) sequences (SPACE, CUBE, VISTA) in the detection of brain metastases at both 1.5 T and 3 T. KEY POINTS: • Accurate detection of brain metastases is critical due to advances in radiosurgery. • T1-weighted SE sequences are superior to gradient echo in detecting small metastases. • T1-weighted 3D-TSE sequences may achieve high resolution and relative insensitivity to artifacts. • T1-weighted 3D-TSE sequences have been recommended in imaging brain metastases at 3 T. • We found T1-weighted 3D-TSE equivalent to thin-slice SE at 1.5 T and 3 T.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24005591
003      
CZ-PrNML
005      
20240412130941.0
007      
ta
008      
240405s2024 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1186/s13244-024-01643-6 $2 doi
035    __
$a (PubMed)38483648
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Vymazal, Josef $u Department of Radiology, Na Homolce Hospital, Roentgenova 2, Prague, 150 30, Czech Republic
245    10
$a Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T / $c J. Vymazal, Z. Ryznarova, AM. Rulseh
520    9_
$a OBJECTIVES: Accurate detection of metastatic brain lesions (MBL) is critical due to advances in radiosurgery. We compared the results of three readers in detecting MBL using T1-weighted 2D spin echo (SE) and sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) sequences with whole-brain coverage at both 1.5 T and 3 T. METHODS: Fifty-six patients evaluated for MBL were included and underwent a standard protocol (1.5 T, n = 37; 3 T, n = 19), including postcontrast T1-weighted SE and SPACE. The rating was performed by three raters in two sessions > six weeks apart. The true number of MBL was determined using all available imaging including follow-up. Intraclass correlations for intra-rater and inter-rater agreement were calculated. Signal intensity ratios (SIR; enhancing lesion, white matter) were determined on a subset of 46 MBL > 4 mm. A paired t-test was used to evaluate postcontrast sequence order and SIR. Reader accuracy was evaluated by the coefficient of determination. RESULTS: A total of 135 MBL were identified (mean/subject 2.41, SD 6.4). The intra-rater agreement was excellent for all 3 raters (ICC = 0.97-0.992), as was the inter-rater agreement (ICC = 0.995 SE, 0.99 SPACE). Subjective qualitative ratings were lower for SE images; however, signal intensity ratios were higher in SE sequences. Accuracy was high in all readers for both SE (R2 0.95-0.96) and SPACE (R2 0.91-0.96) sequences. CONCLUSIONS: Although SE sequences are superior to gradient echo sequences in the detection of small MBL, they have long acquisition times and frequent artifacts. We show that T1-weighted SPACE is not inferior to standard thin-slice SE sequences in the detection of MBL at both imaging fields. CRITICAL RELEVANCE STATEMENT: Our results show the suitability of 3D T1-weighted turbo spin echo (TSE) sequences (SPACE, CUBE, VISTA) in the detection of brain metastases at both 1.5 T and 3 T. KEY POINTS: • Accurate detection of brain metastases is critical due to advances in radiosurgery. • T1-weighted SE sequences are superior to gradient echo in detecting small metastases. • T1-weighted 3D-TSE sequences may achieve high resolution and relative insensitivity to artifacts. • T1-weighted 3D-TSE sequences have been recommended in imaging brain metastases at 3 T. • We found T1-weighted 3D-TSE equivalent to thin-slice SE at 1.5 T and 3 T.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Ryznarova, Zuzana $u Department of Radiology, Na Homolce Hospital, Roentgenova 2, Prague, 150 30, Czech Republic
700    1_
$a Rulseh, Aaron M $u Department of Radiology, Na Homolce Hospital, Roentgenova 2, Prague, 150 30, Czech Republic. aarulseh@gmail.com $1 https://orcid.org/0000000283324419
773    0_
$w MED00181719 $t Insights into imaging $x 1869-4101 $g Roč. 15, č. 1 (2024), s. 73
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38483648 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240405 $b ABA008
991    __
$a 20240412130933 $b ABA008
999    __
$a ok $b bmc $g 2075964 $s 1215353
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2024 $b 15 $c 1 $d 73 $e 20240314 $i 1869-4101 $m Insights into imaging $n Insights Imaging $x MED00181719
GRA    __
$a IG204301 $p Ministerstvo Zdravotnictví Ceské Republiky
GRA    __
$a IG204302 $p Ministerstvo Zdravotnictví Ceské Republiky
GRA    __
$a IG204303 $p Ministerstvo Zdravotnictví Ceské Republiky
LZP    __
$a Pubmed-20240405

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...