-
Je něco špatně v tomto záznamu ?
Screening and differential diagnosis of delirium in neurointensive stroke patients
L. Bakošová, D. Kec, M. Škorňa, R. Jura, Z. Kundrata, M. Košťálová, J. Bednařík
Status neindexováno Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2015
Free Medical Journals
od 2015
PubMed Central
od 2015
Europe PubMed Central
od 2015
Open Access Digital Library
od 2015-09-01
ROAD: Directory of Open Access Scholarly Resources
od 2015
- Publikační typ
- časopisecké články MeSH
Diagnosing delirium in neurointensive care is difficult because symptoms of delirium, such as inappropriate speech, may be related to aphasia due to primary brain injury. Therefore, validated screening tools are needed. The aim of this study was to compare two Czech versions of already validated screening tools - the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) - in a cohort of acute stroke patients. We also aimed to assess the pitfalls of delirium detection in the context of non-convulsive status epilepticus (NCSE). We analysed 138 stroke patients admitted to the neurological intensive care unit (ICU) or stroke unit. According to expert judgement, which was used as the gold standard, 38 patients (27.54%) developed delirium. The sensitivity and specificity of the ICDSC were 91.60% and 95.33%, respectively, and the positive and negative predictive values were 76.76% and 98.54%, respectively. Similarly, the sensitivity and specificity of CAM-ICU were 75.63% and 96.74%, respectively, and the positive and negative predictive values were 79.65% and 95.93%, respectively. We did not detect an episode of NCSE mimicking delirium in any of our stroke patients who were judged to be delirious by expert assessment. Our results suggest that the ICDSC may be a more suitable tool for delirium screening than the CAM-ICU in patients with neurological deficit. NCSE as a mimic of delirium seems to be less common in the acute phase of stroke than previously reported.
Department of Neurology The University Hospital Brno Jihlavská 20 Brno 62500 Czech Republic
Faculty of Medicine Masaryk University Kamenice 5 Brno 62500 Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24005707
- 003
- CZ-PrNML
- 005
- 20240412131022.0
- 007
- ta
- 008
- 240405s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.heliyon.2024.e25918 $2 doi
- 035 __
- $a (PubMed)38379970
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Bakošová, Lucia $u Faculty of Medicine, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic $u Department of Neurology, The University Hospital Brno, Jihlavská 20, Brno, 62500, Czech Republic
- 245 10
- $a Screening and differential diagnosis of delirium in neurointensive stroke patients / $c L. Bakošová, D. Kec, M. Škorňa, R. Jura, Z. Kundrata, M. Košťálová, J. Bednařík
- 520 9_
- $a Diagnosing delirium in neurointensive care is difficult because symptoms of delirium, such as inappropriate speech, may be related to aphasia due to primary brain injury. Therefore, validated screening tools are needed. The aim of this study was to compare two Czech versions of already validated screening tools - the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) - in a cohort of acute stroke patients. We also aimed to assess the pitfalls of delirium detection in the context of non-convulsive status epilepticus (NCSE). We analysed 138 stroke patients admitted to the neurological intensive care unit (ICU) or stroke unit. According to expert judgement, which was used as the gold standard, 38 patients (27.54%) developed delirium. The sensitivity and specificity of the ICDSC were 91.60% and 95.33%, respectively, and the positive and negative predictive values were 76.76% and 98.54%, respectively. Similarly, the sensitivity and specificity of CAM-ICU were 75.63% and 96.74%, respectively, and the positive and negative predictive values were 79.65% and 95.93%, respectively. We did not detect an episode of NCSE mimicking delirium in any of our stroke patients who were judged to be delirious by expert assessment. Our results suggest that the ICDSC may be a more suitable tool for delirium screening than the CAM-ICU in patients with neurological deficit. NCSE as a mimic of delirium seems to be less common in the acute phase of stroke than previously reported.
- 590 __
- $a NEINDEXOVÁNO
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kec, David $u Faculty of Medicine, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic $u Department of Neurology, The University Hospital Brno, Jihlavská 20, Brno, 62500, Czech Republic
- 700 1_
- $a Škorňa, Miroslav $u Faculty of Medicine, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic $u Department of Neurology, The University Hospital Brno, Jihlavská 20, Brno, 62500, Czech Republic
- 700 1_
- $a Jura, René $u Faculty of Medicine, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic $u Department of Neurology, The University Hospital Brno, Jihlavská 20, Brno, 62500, Czech Republic
- 700 1_
- $a Kundrata, Zdeněk $u Faculty of Medicine, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic $u Department of Neurology, The University Hospital Brno, Jihlavská 20, Brno, 62500, Czech Republic
- 700 1_
- $a Košťálová, Milena $u Faculty of Medicine, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic $u Department of Neurology, The University Hospital Brno, Jihlavská 20, Brno, 62500, Czech Republic
- 700 1_
- $a Bednařík, Josef $u Faculty of Medicine, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic $u Department of Neurology, The University Hospital Brno, Jihlavská 20, Brno, 62500, Czech Republic
- 773 0_
- $w MED00190064 $t Heliyon $x 2405-8440 $g Roč. 10, č. 4 (2024), s. e25918
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38379970 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240405 $b ABA008
- 991 __
- $a 20240412131014 $b ABA008
- 999 __
- $a ok $b bmc $g 2075999 $s 1215469
- BAS __
- $a 3
- BAS __
- $a PreBMC-PubMed-not-MEDLINE
- BMC __
- $a 2024 $b 10 $c 4 $d e25918 $e 20240210 $i 2405-8440 $m Heliyon $n Heliyon $x MED00190064
- LZP __
- $a Pubmed-20240405