P. Voda, J. Kremláček, D. Kordek, M. Chutná, A. Bezrouk

. 2024 ; 14 (1) : 4244. [pub] 20240220

Status neindexováno Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24005747

Grantová podpora
NU22-06-00039 Ministerstvo Zdravotnictví Ceské Republiky
NU22-06-00039 Ministerstvo Zdravotnictví Ceské Republiky

A rapid checkerboard pattern change is used to elicit pattern-reversal visual evoked potentials (PR VEPs). CRT or LCD monitors do not allow immediate reversal of the entire pattern. The study aimed to construct a new stimulator whose characteristics approximate an instantaneous reversal and verify whether the improvement is reflected in PR VEPs. A new stimulator using a matrix of 12 × 48 independent white square LEDs was designed and compared with LCDs and CRTs. The effect on the PR VEP peak times and amplitudes of N70, P100, and P140 waves was evaluated in ten subjects. The LED stimulator showed significantly better performance in the rate of change of illuminance, change of pattern, luminance settling and stability. The PR VEP amplitudes of N75, P100, and N140 did not show significant differences. The sum of interpeak amplitudes was significantly larger for the LCD than for the other monitors. The peak times of the waves evoked by the LED were shorter than those evoked by the LCD and CRT for the N75 wave and a check size of 30 ́. LED stimulators are a better alternative to CRTs for PR VEPs than current LCDs. LEDs also seem to be better than CRTs, but further research is necessary to obtain significant results.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24005747
003      
CZ-PrNML
005      
20240412131030.0
007      
ta
008      
240405s2024 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/s41598-024-54776-5 $2 doi
035    __
$a (PubMed)38378903
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Voda, P $u Department of Medical Biophysics, Medical Faculty in Hradec Kralove, Charles University, Simkova 870, 500 03, Hradec Kralove, Czech Republic
245    10
$a True pattern-reversal LED stimulator and its comparison to LCD and CRT displays: visual evoked potential study / $c P. Voda, J. Kremláček, D. Kordek, M. Chutná, A. Bezrouk
520    9_
$a A rapid checkerboard pattern change is used to elicit pattern-reversal visual evoked potentials (PR VEPs). CRT or LCD monitors do not allow immediate reversal of the entire pattern. The study aimed to construct a new stimulator whose characteristics approximate an instantaneous reversal and verify whether the improvement is reflected in PR VEPs. A new stimulator using a matrix of 12 × 48 independent white square LEDs was designed and compared with LCDs and CRTs. The effect on the PR VEP peak times and amplitudes of N70, P100, and P140 waves was evaluated in ten subjects. The LED stimulator showed significantly better performance in the rate of change of illuminance, change of pattern, luminance settling and stability. The PR VEP amplitudes of N75, P100, and N140 did not show significant differences. The sum of interpeak amplitudes was significantly larger for the LCD than for the other monitors. The peak times of the waves evoked by the LED were shorter than those evoked by the LCD and CRT for the N75 wave and a check size of 30 ́. LED stimulators are a better alternative to CRTs for PR VEPs than current LCDs. LEDs also seem to be better than CRTs, but further research is necessary to obtain significant results.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kremláček, J $u Department of Medical Biophysics, Medical Faculty in Hradec Kralove, Charles University, Simkova 870, 500 03, Hradec Kralove, Czech Republic. kremlack@lfhk.cuni.cz
700    1_
$a Kordek, D $u Department of Medical Biophysics, Medical Faculty in Hradec Kralove, Charles University, Simkova 870, 500 03, Hradec Kralove, Czech Republic
700    1_
$a Chutná, M $u Department of Pathological Physiology, Medical Faculty in Hradec Kralove, Charles University, Simkova 870, 500 03, Hradec Kralove, Czech Republic
700    1_
$a Bezrouk, A $u Department of Medical Biophysics, Medical Faculty in Hradec Kralove, Charles University, Simkova 870, 500 03, Hradec Kralove, Czech Republic
773    0_
$w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 14, č. 1 (2024), s. 4244
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38378903 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240405 $b ABA008
991    __
$a 20240412131023 $b ABA008
999    __
$a ok $b bmc $g 2076012 $s 1215509
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2024 $b 14 $c 1 $d 4244 $e 20240220 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
GRA    __
$a NU22-06-00039 $p Ministerstvo Zdravotnictví Ceské Republiky
GRA    __
$a NU22-06-00039 $p Ministerstvo Zdravotnictví Ceské Republiky
LZP    __
$a Pubmed-20240405

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...