Intra and inter-rater variability in the construction of patient-specific musculoskeletal model

J. Votava, A. Kratochvíl, M. Daniel

. 2024 ; 108 (-) : 195-198. [pub] 20231207

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24007347

BACKGROUND: Variations observed in biomechanical studies might be attributed to errors made by operators during the construction of musculoskeletal models, rather than being solely attributed to patient-specific geometry. RESEARCH QUESTION: What is the impact of operator errors on the construction of musculoskeletal models, and how does it affect the estimation of muscle moment arms and hip joint reaction forces? METHODS: Thirteen independent operators participated in defining the muscle model, while a single operator performed 13 repetitions to define the muscle model based on 3D bone geometry. For each model, the muscle moment arms relative to the hip joint center of rotation was evaluated. Additionally, the hip joint reaction force during one-legged stance was assessed using static inverse optimization. RESULTS: The results indicated high levels of consistency, as evidenced by the intra- rater and inter-rater agreement measured by the Intraclass Correlation Coefficient (ICC), which yielded values of 0.95 and 0.99, respectively. However, the estimated muscle moment arms exhibited an error of up to 16 mm compared to the reference musculoskeletal model. It was found that muscles attached to prominent anatomical landmarks were specified with greater accuracy than those attached over larger areas. Furthermore, the variability in estimated moment arms contributed to variations of up to 12% in the hip joint reaction forces. SIGNIFICANCE: Both moment arm and muscle force demonstrated significantly lower variability when assessed by a single operator, suggesting the preference for employing a single operator in the creation of musculoskeletal models for clinical biomechanical studies.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24007347
003      
CZ-PrNML
005      
20240423155908.0
007      
ta
008      
240412e20231207enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.gaitpost.2023.12.001 $2 doi
035    __
$a (PubMed)38103325
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Votava, Jan $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Technicka 4, 16000 Prague, Czechia
245    10
$a Intra and inter-rater variability in the construction of patient-specific musculoskeletal model / $c J. Votava, A. Kratochvíl, M. Daniel
520    9_
$a BACKGROUND: Variations observed in biomechanical studies might be attributed to errors made by operators during the construction of musculoskeletal models, rather than being solely attributed to patient-specific geometry. RESEARCH QUESTION: What is the impact of operator errors on the construction of musculoskeletal models, and how does it affect the estimation of muscle moment arms and hip joint reaction forces? METHODS: Thirteen independent operators participated in defining the muscle model, while a single operator performed 13 repetitions to define the muscle model based on 3D bone geometry. For each model, the muscle moment arms relative to the hip joint center of rotation was evaluated. Additionally, the hip joint reaction force during one-legged stance was assessed using static inverse optimization. RESULTS: The results indicated high levels of consistency, as evidenced by the intra- rater and inter-rater agreement measured by the Intraclass Correlation Coefficient (ICC), which yielded values of 0.95 and 0.99, respectively. However, the estimated muscle moment arms exhibited an error of up to 16 mm compared to the reference musculoskeletal model. It was found that muscles attached to prominent anatomical landmarks were specified with greater accuracy than those attached over larger areas. Furthermore, the variability in estimated moment arms contributed to variations of up to 12% in the hip joint reaction forces. SIGNIFICANCE: Both moment arm and muscle force demonstrated significantly lower variability when assessed by a single operator, suggesting the preference for employing a single operator in the creation of musculoskeletal models for clinical biomechanical studies.
650    _2
$a lidé $7 D006801
650    12
$a kosterní svaly $x fyziologie $7 D018482
650    _2
$a biomechanika $7 D001696
650    12
$a kyčelní kloub $x fyziologie $7 D006621
650    _2
$a biologické modely $7 D008954
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kratochvíl, Adam $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Technicka 4, 16000 Prague, Czechia
700    1_
$a Daniel, Matej $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Technicka 4, 16000 Prague, Czechia. Electronic address: matej.daniel@fs.cvut.cz
773    0_
$w MED00001869 $t Gait & posture $x 1879-2219 $g Roč. 108 (20231207), s. 195-198
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38103325 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240412 $b ABA008
991    __
$a 20240423155904 $b ABA008
999    __
$a ok $b bmc $g 2081371 $s 1217114
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 108 $c - $d 195-198 $e 20231207 $i 1879-2219 $m Gait & posture $n Gait posture $x MED00001869
LZP    __
$a Pubmed-20240412

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...