• Something wrong with this record ?

Acute and long-term results with the 3rd generation visually guided laser balloon ablation system for pv isolation

M. Funasako, J. Petrů, P. Hála, M. Janotka, J. Škoda, M. Chovanec, L. Šedivá, VY. Reddy, P. Neužil

. 2024 ; 67 (1) : 53-60. [pub] 20230220

Language English Country Netherlands

Document type Journal Article

E-resources Online Full text

NLK ProQuest Central from 1997-07-01 to 1 year ago
Medline Complete (EBSCOhost) from 2011-01-01 to 1 year ago
Health & Medicine (ProQuest) from 1997-07-01 to 1 year ago

BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24007853
003      
CZ-PrNML
005      
20240423160332.0
007      
ta
008      
240412s2024 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s10840-023-01499-8 $2 doi
035    __
$a (PubMed)36805921
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Funasako, Moritoshi $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic. toshi.funasako@gmail.com $1 https://orcid.org/0000000216203924
245    10
$a Acute and long-term results with the 3rd generation visually guided laser balloon ablation system for pv isolation / $c M. Funasako, J. Petrů, P. Hála, M. Janotka, J. Škoda, M. Chovanec, L. Šedivá, VY. Reddy, P. Neužil
520    9_
$a BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.
650    _2
$a lidé $7 D006801
650    _2
$a lidé středního věku $7 D008875
650    _2
$a senioři $7 D000368
650    _2
$a výsledek terapie $7 D016896
650    12
$a fibrilace síní $7 D001281
650    12
$a laserová terapie $x metody $7 D053685
650    12
$a venae pulmonales $x chirurgie $7 D011667
650    12
$a katetrizační ablace $x metody $7 D017115
655    _2
$a časopisecké články $7 D016428
700    1_
$a Petrů, Jan $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
700    1_
$a Hála, Pavel $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
700    1_
$a Janotka, Marek $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
700    1_
$a Škoda, Jan $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
700    1_
$a Chovanec, Milan $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
700    1_
$a Šedivá, Lucie $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
700    1_
$a Reddy, Vivek Y $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic $u The Helmsley Electrophysiology Center, Mount Sinai School of Medicine, New York, NY, USA
700    1_
$a Neužil, Petr $u Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
773    0_
$w MED00008134 $t Journal of interventional cardiac electrophysiology $x 1572-8595 $g Roč. 67, č. 1 (2024), s. 53-60
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36805921 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240412 $b ABA008
991    __
$a 20240423160328 $b ABA008
999    __
$a ok $b bmc $g 2081704 $s 1217620
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 67 $c 1 $d 53-60 $e 20230220 $i 1572-8595 $m Journal of interventional cardiac electrophysiology $n J Interv Card Electrophysiol $x MED00008134
LZP    __
$a Pubmed-20240412

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...