Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Roles of spectral dual-layer CT, D-dimer concentration, and COVID-19 pneumonia in diagnosis of pulmonary embolism

T. Jůza, V. Válek, D. Vlk, M. Dostál, T. Andrašina

. 2024 ; 12 (-) : 100575. [pub] 20240604

Status neindexováno Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc24012614

PURPOSE: To demonstrate advantages of spectral dual-layer computed tomography (CT) in diagnosing pulmonary embolism (PE). To compare D-dimer values in patients with PE and concomitant COVID-19 pneumonia to those in patients without PE and COVID-19 pneumonia. To compare D-dimer values in cases of minor versus extensive PE. METHODS: A monocentric retrospective study of 1500 CT pulmonary angiographies (CTPAs). Three groups of 500 consecutive examinations: 1) using conventional multidetector CT (CTC), 2) using spectral dual-layer CT (CTS), and 3) of COVID-19 pneumonia patients using spectral dual-layer CT (COV). Only patients with known D-dimer levels were enrolled in the study. RESULTS: Prevalence of inconclusive PE findings differed significantly between CTS and CTC (0.8 % vs. 5.4 %, p < 0.001). In all groups, D-dimer levels were significantly higher in PE positive patients than in patients without PE (CTC, 8.04 vs. 3.05 mg/L; CTS, 6.92 vs. 2.57 mg/L; COV, 10.26 vs. 2.72 mg/L, p < 0.001). There were also statistically significant differences in D-dimer values between minor and extensive PE in the groups negative for COVID-19 (CTC, 5.16 vs. 8.98 mg/L; CTS 3.52 vs. 9.27 mg/L, p < 0.001). The lowest recorded D-dimer value for proven PE in patients with COVID-19 pneumonia was 1.19 mg/L. CONCLUSION: CTPAs using spectral dual-layer CT reduce the number of inconclusive PE findings. Plasma D-dimer concentration increases with extent of PE. Cut-off value of D-dimer with 100 % sensitivity for patients with COVID-19 pneumonia could be doubled to 1.0 mg/L. This threshold would have saved 110 (22 %) examinations in our cohort.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24012614
003      
CZ-PrNML
005      
20240726151422.0
007      
ta
008      
240723e20240604enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ejro.2024.100575 $2 doi
035    __
$a (PubMed)38882633
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Jůza, Tomáš $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Jihlavská 340/20, Brno 625 00, Czech Republic $u Department of Biophysics, Faculty of Medicine, Masaryk University, Kamenice 126/3, Brno 625 00, Czech Republic
245    10
$a Roles of spectral dual-layer CT, D-dimer concentration, and COVID-19 pneumonia in diagnosis of pulmonary embolism / $c T. Jůza, V. Válek, D. Vlk, M. Dostál, T. Andrašina
520    9_
$a PURPOSE: To demonstrate advantages of spectral dual-layer computed tomography (CT) in diagnosing pulmonary embolism (PE). To compare D-dimer values in patients with PE and concomitant COVID-19 pneumonia to those in patients without PE and COVID-19 pneumonia. To compare D-dimer values in cases of minor versus extensive PE. METHODS: A monocentric retrospective study of 1500 CT pulmonary angiographies (CTPAs). Three groups of 500 consecutive examinations: 1) using conventional multidetector CT (CTC), 2) using spectral dual-layer CT (CTS), and 3) of COVID-19 pneumonia patients using spectral dual-layer CT (COV). Only patients with known D-dimer levels were enrolled in the study. RESULTS: Prevalence of inconclusive PE findings differed significantly between CTS and CTC (0.8 % vs. 5.4 %, p < 0.001). In all groups, D-dimer levels were significantly higher in PE positive patients than in patients without PE (CTC, 8.04 vs. 3.05 mg/L; CTS, 6.92 vs. 2.57 mg/L; COV, 10.26 vs. 2.72 mg/L, p < 0.001). There were also statistically significant differences in D-dimer values between minor and extensive PE in the groups negative for COVID-19 (CTC, 5.16 vs. 8.98 mg/L; CTS 3.52 vs. 9.27 mg/L, p < 0.001). The lowest recorded D-dimer value for proven PE in patients with COVID-19 pneumonia was 1.19 mg/L. CONCLUSION: CTPAs using spectral dual-layer CT reduce the number of inconclusive PE findings. Plasma D-dimer concentration increases with extent of PE. Cut-off value of D-dimer with 100 % sensitivity for patients with COVID-19 pneumonia could be doubled to 1.0 mg/L. This threshold would have saved 110 (22 %) examinations in our cohort.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Válek, Vlastimil $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Jihlavská 340/20, Brno 625 00, Czech Republic
700    1_
$a Vlk, Daniel $u Department of Biophysics, Faculty of Medicine, Masaryk University, Kamenice 126/3, Brno 625 00, Czech Republic
700    1_
$a Dostál, Marek $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Jihlavská 340/20, Brno 625 00, Czech Republic $u Department of Biophysics, Faculty of Medicine, Masaryk University, Kamenice 126/3, Brno 625 00, Czech Republic
700    1_
$a Andrašina, Tomáš $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, University Hospital Brno, Masaryk University, Jihlavská 340/20, Brno 625 00, Czech Republic
773    0_
$w MED00211266 $t European journal of radiology open $x 2352-0477 $g Roč. 12 (20240604), s. 100575
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38882633 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240723 $b ABA008
991    __
$a 20240726151415 $b ABA008
999    __
$a ok $b bmc $g 2125418 $s 1224477
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2024 $b 12 $c - $d 100575 $e 20240604 $i 2352-0477 $m European journal of radiology open $n Eur J Radiol Open $x MED00211266
LZP    __
$a Pubmed-20240723

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...