Deep-learning-based reconstruction of T2-weighted magnetic resonance imaging of the prostate accelerated by compressed sensing provides improved image quality at half the acquisition time

M. Jurka, I. Macova, M. Wagnerova, O. Capoun, R. Jakubicek, P. Ourednicek, L. Lambert, A. Burgetova

. 2024 ; 14 (5) : 3534-3543. [pub] 20240411

Status not-indexed Language English Country China

Document type Journal Article

BACKGROUND: Deep-learning-based reconstruction (DLR) improves the quality of magnetic resonance (MR) images which allows faster acquisitions. The aim of this study was to compare the image quality of standard and accelerated T2 weighted turbo-spin-echo (TSE) images of the prostate reconstructed with and without DLR and to find associations between perceived image quality and calculated image characteristics. METHODS: In a cohort of 47 prospectively enrolled consecutive patients referred for bi-parametric prostate magnetic resonance imaging (MRI), two T2-TSE acquisitions in the transverse plane were acquired on a 3T scanner-a standard T2-TSE sequence and a short sequence accelerated by a factor of two using compressed sensing (CS). The images were reconstructed with and without DLR in super-resolution mode. The image quality was rated in six domains. Signal-to-noise ratio (SNR), and image sharpness were measured. RESULTS: The mean acquisition time was 281±23 s for the standard and 140±12 s for the short acquisition (P<0.0001). DLR images had higher sharpness compared to non-DLR (P<0.001). Short and short-DLR had lower SNR than the standard and standard-DLR (P<0.001). The perceived image quality of short-DLR was rated better in all categories compared to the standard sequence (P<0.001 to P=0.004). All domains of subjective evaluation were correlated with measured image sharpness (P<0.001). CONCLUSIONS: T2-TSE acquisition of the prostate accelerated using CS combined with DLR reconstruction provides images with increased sharpness that have a superior quality as perceived by human readers compared to standard T2-TSE. The perceived image quality is correlated with measured image contrast.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24012873
003      
CZ-PrNML
005      
20240726151434.0
007      
ta
008      
240723s2024 cc f 000 0|eng||
009      
AR
024    7_
$a 10.21037/qims-23-1488 $2 doi
035    __
$a (PubMed)38720867
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a cc
100    1_
$a Jurka, Martin $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
245    10
$a Deep-learning-based reconstruction of T2-weighted magnetic resonance imaging of the prostate accelerated by compressed sensing provides improved image quality at half the acquisition time / $c M. Jurka, I. Macova, M. Wagnerova, O. Capoun, R. Jakubicek, P. Ourednicek, L. Lambert, A. Burgetova
520    9_
$a BACKGROUND: Deep-learning-based reconstruction (DLR) improves the quality of magnetic resonance (MR) images which allows faster acquisitions. The aim of this study was to compare the image quality of standard and accelerated T2 weighted turbo-spin-echo (TSE) images of the prostate reconstructed with and without DLR and to find associations between perceived image quality and calculated image characteristics. METHODS: In a cohort of 47 prospectively enrolled consecutive patients referred for bi-parametric prostate magnetic resonance imaging (MRI), two T2-TSE acquisitions in the transverse plane were acquired on a 3T scanner-a standard T2-TSE sequence and a short sequence accelerated by a factor of two using compressed sensing (CS). The images were reconstructed with and without DLR in super-resolution mode. The image quality was rated in six domains. Signal-to-noise ratio (SNR), and image sharpness were measured. RESULTS: The mean acquisition time was 281±23 s for the standard and 140±12 s for the short acquisition (P<0.0001). DLR images had higher sharpness compared to non-DLR (P<0.001). Short and short-DLR had lower SNR than the standard and standard-DLR (P<0.001). The perceived image quality of short-DLR was rated better in all categories compared to the standard sequence (P<0.001 to P=0.004). All domains of subjective evaluation were correlated with measured image sharpness (P<0.001). CONCLUSIONS: T2-TSE acquisition of the prostate accelerated using CS combined with DLR reconstruction provides images with increased sharpness that have a superior quality as perceived by human readers compared to standard T2-TSE. The perceived image quality is correlated with measured image contrast.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Macova, Iva $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
700    1_
$a Wagnerova, Monika $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
700    1_
$a Capoun, Otakar $u Department of Urology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
700    1_
$a Jakubicek, Roman $u Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
700    1_
$a Ourednicek, Petr $u Department of Medical Imaging, St. Anna University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
700    1_
$a Lambert, Lukas $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic $1 https://orcid.org/0000000322994707 $7 xx0145830
700    1_
$a Burgetova, Andrea $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic $1 https://orcid.org/0000000299752338 $7 xx0163957
773    0_
$w MED00200676 $t Quantitative imaging in medicine and surgery $x 2223-4292 $g Roč. 14, č. 5 (2024), s. 3534-3543
856    41
$u https://pubmed.ncbi.nlm.nih.gov/38720867 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20240723 $b ABA008
991    __
$a 20240726151426 $b ABA008
999    __
$a ok $b bmc $g 2125505 $s 1224736
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2024 $b 14 $c 5 $d 3534-3543 $e 20240411 $i 2223-4292 $m Quantitative imaging in medicine and surgery $n Quant Imaging Med Surg $x MED00200676
LZP    __
$a Pubmed-20240723

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...