Something wrong with this record ?
NeuroPorator: An open-source, current-limited electroporator for safe in utero gene transfer
N. Procházková, MT. Nguyenová, M. Řehořová, J. Kudláček, J. Chvojka, J. Ziak, M. Balaštík, J. Otáhal, P. Jiruška, O. Novák
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Equipment Design MeSH
- Electroporation * methods instrumentation MeSH
- Embryo, Mammalian MeSH
- Mice MeSH
- Gene Transfer Techniques * instrumentation MeSH
- Pregnancy MeSH
- Uterus MeSH
- Animals MeSH
- Check Tag
- Mice MeSH
- Pregnancy MeSH
- Female MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
BACKGROUND: Electroporation is an effective technique for genetic manipulation of cells, both in vitro and in vivo. In utero electroporation (IUE) is a special case, which represents a fine application of this technique to genetically modify specific tissues of embryos during prenatal development. Commercially available electroporators are expensive and not fully customizable. We have designed and produced an inexpensive, open-design, and customizable electroporator optimized for safe IUE. We introduce NeuroPorator. METHOD: We used off-the-shelf electrical parts, a single-board microcontroller, and a cheap data logger to build an open-design electroporator. We included a safety circuit to limit the applied electrical current to protect the embryos. We added full documentation, design files, and assembly instructions. RESULT: NeuroPorator output is on par with commercially available devices. Furthermore, the adjustable current limiter protects both the embryos and the uterus from overcurrent damage. A built-in data acquisition module provides real-time visualization and recordings of the actual voltage/current pulses applied to each embryo. Function of NeuroPorator has been demonstrated by inducing focal cortical dysplasia in mice. SIGNIFICANCE AND CONCLUSION: The simple and fully open design enables quick and cheap construction of the device and facilitates further customization. The features of NeuroPorator can accelerate the IUE technique implementation in any laboratory and speed up its learning curve.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24013728
- 003
- CZ-PrNML
- 005
- 20240905133451.0
- 007
- ta
- 008
- 240725e20240328ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jneumeth.2024.110126 $2 doi
- 035 __
- $a (PubMed)38554786
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Procházková, Natálie $u Department of Physiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic
- 245 10
- $a NeuroPorator: An open-source, current-limited electroporator for safe in utero gene transfer / $c N. Procházková, MT. Nguyenová, M. Řehořová, J. Kudláček, J. Chvojka, J. Ziak, M. Balaštík, J. Otáhal, P. Jiruška, O. Novák
- 520 9_
- $a BACKGROUND: Electroporation is an effective technique for genetic manipulation of cells, both in vitro and in vivo. In utero electroporation (IUE) is a special case, which represents a fine application of this technique to genetically modify specific tissues of embryos during prenatal development. Commercially available electroporators are expensive and not fully customizable. We have designed and produced an inexpensive, open-design, and customizable electroporator optimized for safe IUE. We introduce NeuroPorator. METHOD: We used off-the-shelf electrical parts, a single-board microcontroller, and a cheap data logger to build an open-design electroporator. We included a safety circuit to limit the applied electrical current to protect the embryos. We added full documentation, design files, and assembly instructions. RESULT: NeuroPorator output is on par with commercially available devices. Furthermore, the adjustable current limiter protects both the embryos and the uterus from overcurrent damage. A built-in data acquisition module provides real-time visualization and recordings of the actual voltage/current pulses applied to each embryo. Function of NeuroPorator has been demonstrated by inducing focal cortical dysplasia in mice. SIGNIFICANCE AND CONCLUSION: The simple and fully open design enables quick and cheap construction of the device and facilitates further customization. The features of NeuroPorator can accelerate the IUE technique implementation in any laboratory and speed up its learning curve.
- 650 _2
- $a zvířata $7 D000818
- 650 12
- $a elektroporace $x metody $x přístrojové vybavení $7 D018274
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a myši $7 D051379
- 650 12
- $a technika přenosu genů $x přístrojové vybavení $7 D018014
- 650 _2
- $a těhotenství $7 D011247
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a uterus $7 D014599
- 650 _2
- $a embryo savčí $7 D004622
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Nguyenová, Minh-Thao $u Department of Physiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic
- 700 1_
- $a Řehořová, Monika $u Department of Physiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic
- 700 1_
- $a Kudláček, Jan $u Department of Physiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic
- 700 1_
- $a Chvojka, Jan $u Department of Physiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic
- 700 1_
- $a Ziak, Jakub $u Laboratory of Molecular Neurobiology, Institute of Physiology, The Czech Academy of Sciences, Videnska 1083, Prague 14200, Czech Republic
- 700 1_
- $a Balaštík, Martin $u Laboratory of Molecular Neurobiology, Institute of Physiology, The Czech Academy of Sciences, Videnska 1083, Prague 14200, Czech Republic
- 700 1_
- $a Otáhal, Jakub $u Department of Pathophysiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic
- 700 1_
- $a Jiruška, Přemysl $u Department of Physiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic
- 700 1_
- $a Novák, Ondřej $u Department of Physiology, Second Faculty of Medicine, Charles University, Plzenska 311, Prague 15000, Czech Republic. Electronic address: ondrej.novak@lfmotol.cuni.cz
- 773 0_
- $w MED00002841 $t Journal of neuroscience methods $x 1872-678X $g Roč. 406 (20240328), s. 110126
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38554786 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240725 $b ABA008
- 991 __
- $a 20240905133445 $b ABA008
- 999 __
- $a ok $b bmc $g 2143493 $s 1225594
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 406 $c - $d 110126 $e 20240328 $i 1872-678X $m Journal of neuroscience methods $n J Neurosci Methods $x MED00002841
- LZP __
- $a Pubmed-20240725