Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Optimized target delineation procedure for the radiosurgery treatment of ventricular tachycardia: observer-independent accuracy

J. Hecko, L. Knybel, M. Rybar, M. Penhaker, O. Jiravsky, R. Neuwirth, M. Sramko, J. Haskova, J. Kautzner, J. Cvek

. 2024 ; 29 (3) : 280-289. [pub] 20240722

Status not-indexed Language English Country Poland

Document type Journal Article

BACKGROUND: Part of the current stereotactic arrythmia radioablation (STAR) workflow is transfer of findings from the electroanatomic mapping (EAM) to computed tomography (CT). Here, we analyzed inter- and intraobserver variation in a modified EAM-CT registration using automatic registration algorithms designed to yield higher robustness. MATERIALS AND METHODS: This work is based on data of 10 patients who had previously undergone STAR. Two observers participated in this study: (1) an electrophysiologist technician (cardiology) with substatial experience in EAM-CT merge, and (2) a clinical engineer (radiotherapy) with minimum experience with EAM-CT merge. EAM-CT merge consists of 3 main steps: segmentation of left ventricle from CT (CT LV), registration of the CT LV and EAM, clinical target volume (CTV) delineation from EAM specific points. Mean Hausdorff distance (MHD), Dice Similarity Coefficient (DSC) and absolute difference in Center of Gravity (CoG) were used to assess intra/interobserver variability. RESULTS: Intraobserver variability: The mean DSC and MHD for 3 CT LVs altogether was 0.92 ± 0.01 and 1.49 ± 0.23 mm. The mean DSC and MHD for 3 CTVs altogether was 0,82 ± 0,06 and 0,71 ± 0,22 mm. Interobserver variability: Segmented CT LVs showed great similarity (mean DSC of 0,91 ± 0,01, MHD of 1,86 ± 0,47 mm). The mean DSC comparing CTVs from both observers was 0,81 ± 0,11 and MHD was 0,87 ± 0,45 mm. CONCLUSIONS: The high interobserver similarity of segmented LVs and delineated CTVs confirmed the robustness of the proposed method. Even an inexperienced user can perform a precise EAM-CT merge following workflow instructions.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc24018188
003      
CZ-PrNML
005      
20241016081853.0
007      
ta
008      
241008s2024 pl f 000 0|eng||
009      
AR
024    7_
$a 10.5603/rpor.100387 $2 doi
035    __
$a (PubMed)39144262
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a pl
100    1_
$a Hecko, Jan $u Department of Cardiology, Podlesi Hospital, Trinec, Czech Republic $u VŠB-Technical University of Ostrava, Ostrava, Czech Republic
245    10
$a Optimized target delineation procedure for the radiosurgery treatment of ventricular tachycardia: observer-independent accuracy / $c J. Hecko, L. Knybel, M. Rybar, M. Penhaker, O. Jiravsky, R. Neuwirth, M. Sramko, J. Haskova, J. Kautzner, J. Cvek
520    9_
$a BACKGROUND: Part of the current stereotactic arrythmia radioablation (STAR) workflow is transfer of findings from the electroanatomic mapping (EAM) to computed tomography (CT). Here, we analyzed inter- and intraobserver variation in a modified EAM-CT registration using automatic registration algorithms designed to yield higher robustness. MATERIALS AND METHODS: This work is based on data of 10 patients who had previously undergone STAR. Two observers participated in this study: (1) an electrophysiologist technician (cardiology) with substatial experience in EAM-CT merge, and (2) a clinical engineer (radiotherapy) with minimum experience with EAM-CT merge. EAM-CT merge consists of 3 main steps: segmentation of left ventricle from CT (CT LV), registration of the CT LV and EAM, clinical target volume (CTV) delineation from EAM specific points. Mean Hausdorff distance (MHD), Dice Similarity Coefficient (DSC) and absolute difference in Center of Gravity (CoG) were used to assess intra/interobserver variability. RESULTS: Intraobserver variability: The mean DSC and MHD for 3 CT LVs altogether was 0.92 ± 0.01 and 1.49 ± 0.23 mm. The mean DSC and MHD for 3 CTVs altogether was 0,82 ± 0,06 and 0,71 ± 0,22 mm. Interobserver variability: Segmented CT LVs showed great similarity (mean DSC of 0,91 ± 0,01, MHD of 1,86 ± 0,47 mm). The mean DSC comparing CTVs from both observers was 0,81 ± 0,11 and MHD was 0,87 ± 0,45 mm. CONCLUSIONS: The high interobserver similarity of segmented LVs and delineated CTVs confirmed the robustness of the proposed method. Even an inexperienced user can perform a precise EAM-CT merge following workflow instructions.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Knybel, Lukas $u Department of Oncology, University Hospital Ostrava and, Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic
700    1_
$a Rybar, Marian $u Department of Biomedical Technology ,Czech Technical University in Prague, Kladno, Czech Republic
700    1_
$a Penhaker, Marek $u VŠB-Technical University of Ostrava, Ostrava, Czech Republic
700    1_
$a Jiravsky, Otakar $u Department of Cardiology, Podlesi Hospital, Trinec, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czechia
700    1_
$a Neuwirth, Radek $u Department of Cardiology, Podlesi Hospital, Trinec, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czechia
700    1_
$a Sramko, Marek $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
700    1_
$a Haskova, Jana $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
700    1_
$a Kautzner, Josef $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
700    1_
$a Cvek, Jakub $u Department of Oncology, University Hospital Ostrava and, Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic
773    0_
$w MED00154188 $t Reports of Practical Oncology and Radiotherapy $x 1507-1367 $g Roč. 29, č. 3 (2024), s. 280-289
856    41
$u https://pubmed.ncbi.nlm.nih.gov/39144262 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20241008 $b ABA008
991    __
$a 20241016081848 $b ABA008
999    __
$a ok $b bmc $g 2196487 $s 1230139
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2024 $b 29 $c 3 $d 280-289 $e 20240722 $i 1507-1367 $m Reports of Practical Oncology and Radiotherapy $n Rep Pract Oncol Radiother $x MED00154188
LZP    __
$a Pubmed-20241008

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...