Optimized target delineation procedure for the radiosurgery treatment of ventricular tachycardia: observer-independent accuracy
J. Hecko, L. Knybel, M. Rybar, M. Penhaker, O. Jiravsky, R. Neuwirth, M. Sramko, J. Haskova, J. Kautzner, J. Cvek
Status not-indexed Language English Country Poland
Document type Journal Article
NLK
Directory of Open Access Journals
from 2001
Free Medical Journals
from 2010
PubMed Central
from 2010
Europe PubMed Central
from 2010 to 1 year ago
ROAD: Directory of Open Access Scholarly Resources
from 1998
PubMed
39144262
DOI
10.5603/rpor.100387
Knihovny.cz E-resources
- Publication type
- Journal Article MeSH
BACKGROUND: Part of the current stereotactic arrythmia radioablation (STAR) workflow is transfer of findings from the electroanatomic mapping (EAM) to computed tomography (CT). Here, we analyzed inter- and intraobserver variation in a modified EAM-CT registration using automatic registration algorithms designed to yield higher robustness. MATERIALS AND METHODS: This work is based on data of 10 patients who had previously undergone STAR. Two observers participated in this study: (1) an electrophysiologist technician (cardiology) with substatial experience in EAM-CT merge, and (2) a clinical engineer (radiotherapy) with minimum experience with EAM-CT merge. EAM-CT merge consists of 3 main steps: segmentation of left ventricle from CT (CT LV), registration of the CT LV and EAM, clinical target volume (CTV) delineation from EAM specific points. Mean Hausdorff distance (MHD), Dice Similarity Coefficient (DSC) and absolute difference in Center of Gravity (CoG) were used to assess intra/interobserver variability. RESULTS: Intraobserver variability: The mean DSC and MHD for 3 CT LVs altogether was 0.92 ± 0.01 and 1.49 ± 0.23 mm. The mean DSC and MHD for 3 CTVs altogether was 0,82 ± 0,06 and 0,71 ± 0,22 mm. Interobserver variability: Segmented CT LVs showed great similarity (mean DSC of 0,91 ± 0,01, MHD of 1,86 ± 0,47 mm). The mean DSC comparing CTVs from both observers was 0,81 ± 0,11 and MHD was 0,87 ± 0,45 mm. CONCLUSIONS: The high interobserver similarity of segmented LVs and delineated CTVs confirmed the robustness of the proposed method. Even an inexperienced user can perform a precise EAM-CT merge following workflow instructions.
Department of Biomedical Technology Czech Technical University Prague Kladno Czech Republic
Department of Cardiology Podlesi Hospital Trinec Czech Republic
Department of Oncology University Hospital Ostrava and Ostrava Czech Republic
Faculty of Medicine Masaryk University Brno Czechia
Faculty of Medicine University of Ostrava Ostrava Czech Republic
Institute for Clinical and Experimental Medicine Prague Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24018188
- 003
- CZ-PrNML
- 005
- 20241016081853.0
- 007
- ta
- 008
- 241008s2024 pl f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5603/rpor.100387 $2 doi
- 035 __
- $a (PubMed)39144262
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a pl
- 100 1_
- $a Hecko, Jan $u Department of Cardiology, Podlesi Hospital, Trinec, Czech Republic $u VŠB-Technical University of Ostrava, Ostrava, Czech Republic
- 245 10
- $a Optimized target delineation procedure for the radiosurgery treatment of ventricular tachycardia: observer-independent accuracy / $c J. Hecko, L. Knybel, M. Rybar, M. Penhaker, O. Jiravsky, R. Neuwirth, M. Sramko, J. Haskova, J. Kautzner, J. Cvek
- 520 9_
- $a BACKGROUND: Part of the current stereotactic arrythmia radioablation (STAR) workflow is transfer of findings from the electroanatomic mapping (EAM) to computed tomography (CT). Here, we analyzed inter- and intraobserver variation in a modified EAM-CT registration using automatic registration algorithms designed to yield higher robustness. MATERIALS AND METHODS: This work is based on data of 10 patients who had previously undergone STAR. Two observers participated in this study: (1) an electrophysiologist technician (cardiology) with substatial experience in EAM-CT merge, and (2) a clinical engineer (radiotherapy) with minimum experience with EAM-CT merge. EAM-CT merge consists of 3 main steps: segmentation of left ventricle from CT (CT LV), registration of the CT LV and EAM, clinical target volume (CTV) delineation from EAM specific points. Mean Hausdorff distance (MHD), Dice Similarity Coefficient (DSC) and absolute difference in Center of Gravity (CoG) were used to assess intra/interobserver variability. RESULTS: Intraobserver variability: The mean DSC and MHD for 3 CT LVs altogether was 0.92 ± 0.01 and 1.49 ± 0.23 mm. The mean DSC and MHD for 3 CTVs altogether was 0,82 ± 0,06 and 0,71 ± 0,22 mm. Interobserver variability: Segmented CT LVs showed great similarity (mean DSC of 0,91 ± 0,01, MHD of 1,86 ± 0,47 mm). The mean DSC comparing CTVs from both observers was 0,81 ± 0,11 and MHD was 0,87 ± 0,45 mm. CONCLUSIONS: The high interobserver similarity of segmented LVs and delineated CTVs confirmed the robustness of the proposed method. Even an inexperienced user can perform a precise EAM-CT merge following workflow instructions.
- 590 __
- $a NEINDEXOVÁNO
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Knybel, Lukas $u Department of Oncology, University Hospital Ostrava and, Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic
- 700 1_
- $a Rybar, Marian $u Department of Biomedical Technology ,Czech Technical University in Prague, Kladno, Czech Republic
- 700 1_
- $a Penhaker, Marek $u VŠB-Technical University of Ostrava, Ostrava, Czech Republic
- 700 1_
- $a Jiravsky, Otakar $u Department of Cardiology, Podlesi Hospital, Trinec, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Neuwirth, Radek $u Department of Cardiology, Podlesi Hospital, Trinec, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czechia
- 700 1_
- $a Sramko, Marek $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Haskova, Jana $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Kautzner, Josef $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Cvek, Jakub $u Department of Oncology, University Hospital Ostrava and, Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic
- 773 0_
- $w MED00154188 $t Reports of Practical Oncology and Radiotherapy $x 1507-1367 $g Roč. 29, č. 3 (2024), s. 280-289
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/39144262 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20241008 $b ABA008
- 991 __
- $a 20241016081848 $b ABA008
- 999 __
- $a ok $b bmc $g 2196487 $s 1230139
- BAS __
- $a 3
- BAS __
- $a PreBMC-PubMed-not-MEDLINE
- BMC __
- $a 2024 $b 29 $c 3 $d 280-289 $e 20240722 $i 1507-1367 $m Reports of Practical Oncology and Radiotherapy $n Rep Pract Oncol Radiother $x MED00154188
- LZP __
- $a Pubmed-20241008