Indentation size effect in Knoop and Vickers hardness measurement of dental resin-based composites

A. Roubickova, A. Tichy, R. Vrbova, P. Bradna

. 2025 ; 162 (-) : 106823. [pub] 20241119

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc25002828

OBJECTIVES: Comparisons of material hardness may be affected by the indentation size effect (ISE), which is characterized by increasing hardness values at decreasing loads. This study aimed to assess the influence of load, dwell time and measurement method on ISE in dental resin-based composites with different filler content. METHODS: Knoop (HK) and Vickers (HV) microindentation hardness of Filtek Ultimate Universal Restorative (FU) and Filtek Supreme Flowable Restorative (FF) was measured under different loads (0.098-2.96 N, i.e. 10-300 gf) and dwell times (5-30 s). Their effects on HK and HV were evaluated using repeated measures ANOVA, which was also used to compare the measurement methods. Coefficients of Meyer's equation, proportional specimen resistance (PSR) model and a modified PSR model were calculated using regression analyses. RESULTS: ISE was more pronounced for the highly-filled FU than for the less-filled FF, and HK was more susceptible to ISE than HV. The effect of dwell time was similar for both materials and measurement methods; hardness values decreased with dwell time, significantly between 5 s and 30 s. SIGNIFICANCE: The possible presence of ISE should be considered when determining measurement conditions for the microindentation hardness of dental resin-based composites. HV was found to be less sensitive to ISE and provided stable hardness values at lower loads than HK. Due to the high variability of composites, any hardness measurement should be preceded by mapping the effect of load to ensure that load-independent hardness is measured. If hardness values continue to decrease in the whole range of increasing loads, load-independent hardness can be calculated using the PSR model.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25002828
003      
CZ-PrNML
005      
20250206103906.0
007      
ta
008      
250121e20241119ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jmbbm.2024.106823 $2 doi
035    __
$a (PubMed)39579504
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Roubickova, A $u Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague, Karlovo namesti 32, Prague, 121 11, Czech Republic. Electronic address: adela.roubickova@lf1.cuni.cz
245    10
$a Indentation size effect in Knoop and Vickers hardness measurement of dental resin-based composites / $c A. Roubickova, A. Tichy, R. Vrbova, P. Bradna
520    9_
$a OBJECTIVES: Comparisons of material hardness may be affected by the indentation size effect (ISE), which is characterized by increasing hardness values at decreasing loads. This study aimed to assess the influence of load, dwell time and measurement method on ISE in dental resin-based composites with different filler content. METHODS: Knoop (HK) and Vickers (HV) microindentation hardness of Filtek Ultimate Universal Restorative (FU) and Filtek Supreme Flowable Restorative (FF) was measured under different loads (0.098-2.96 N, i.e. 10-300 gf) and dwell times (5-30 s). Their effects on HK and HV were evaluated using repeated measures ANOVA, which was also used to compare the measurement methods. Coefficients of Meyer's equation, proportional specimen resistance (PSR) model and a modified PSR model were calculated using regression analyses. RESULTS: ISE was more pronounced for the highly-filled FU than for the less-filled FF, and HK was more susceptible to ISE than HV. The effect of dwell time was similar for both materials and measurement methods; hardness values decreased with dwell time, significantly between 5 s and 30 s. SIGNIFICANCE: The possible presence of ISE should be considered when determining measurement conditions for the microindentation hardness of dental resin-based composites. HV was found to be less sensitive to ISE and provided stable hardness values at lower loads than HK. Due to the high variability of composites, any hardness measurement should be preceded by mapping the effect of load to ensure that load-independent hardness is measured. If hardness values continue to decrease in the whole range of increasing loads, load-independent hardness can be calculated using the PSR model.
650    12
$a složené pryskyřice $x chemie $7 D003188
650    12
$a testování materiálů $7 D008422
650    12
$a tvrdost $7 D006244
650    _2
$a testy tvrdosti $7 D006245
655    _2
$a časopisecké články $7 D016428
700    1_
$a Tichy, A $u Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague, Karlovo namesti 32, Prague, 121 11, Czech Republic; Department of Conservative Dentistry and Periodontology, LMU University Hospital, Goethestraße 70, Munich, 80336, Germany. Electronic address: antonin.tichy@lf1.cuni.cz
700    1_
$a Vrbova, R $u Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague, Karlovo namesti 32, Prague, 121 11, Czech Republic
700    1_
$a Bradna, P $u Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague, Karlovo namesti 32, Prague, 121 11, Czech Republic
773    0_
$w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 162 (20241119), s. 106823
856    41
$u https://pubmed.ncbi.nlm.nih.gov/39579504 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250121 $b ABA008
991    __
$a 20250206103902 $b ABA008
999    __
$a ok $b bmc $g 2262930 $s 1238835
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2025 $b 162 $c - $d 106823 $e 20241119 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
LZP    __
$a Pubmed-20250121

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...