Dosimetric and temporal beam characterization of individual pulses in FLASH radiotherapy using Timepix3 pixelated detector placed out-of-field

C. Oancea, K. Sykorova, J. Jakubek, J. Pivec, F. Riemer, S. Worm, A. Bourgouin

. 2025 ; 129 (-) : 104872. [pub] 20241211

Jazyk angličtina Země Itálie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc25010442

BACKGROUND: FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods used to measure the delivered number of pulses, investigate temporal structure of individual pulses and dose-per-pulse (DPP) based on secondary radiation particles produced in the experimental room. METHODS: A 20 MeV electron beam generated from a linear accelerator (LINAC) was delivered to a water phantom. Ultra-high dose-per-pulse electron beams were used with a dose-per-pulse ranging from ̴ 1 Gy to over 7 Gy. The pulse lengths ranged from 1.18 μs to 2.88 μs at a pulse rate frequency of 5 Hz. A semiconductor pixel detector Timepix3 was used to track single secondary particles. Measurements were performed in the air, while the detector was positioned out-of-field at a lateral distance of 200 cm parallel with the LINAC exit window. The dose deposited was measured along with the pulse length and the nanostructure of the pulse. RESULTS: The time of arrival (ToA) of single particles was measured with a resolution of 1.56 ns, while the deposited energy was measured with a resolution of several keV based on the Time over Threshold (ToT) value. The pulse count measured by the Timepix3 detector corresponded with the delivered values, which were measured using an in-flange integrating current transformer (ICT). A linear response (R2 = 0.999) was established between the delivered beam current and the measured dose at the detector position (orders of nGy). The difference between the average measured and delivered pulse length was ∼0.003(30) μs. CONCLUSION: This simple non-invasive method exhibits no limitations on the delivered DPP within the range used during this investigation.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25010442
003      
CZ-PrNML
005      
20250429135144.0
007      
ta
008      
250415e20241211it f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ejmp.2024.104872 $2 doi
035    __
$a (PubMed)39667142
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a it
100    1_
$a Oancea, Cristina $u ADVACAM, U Pergamenky 12, 170 00 Prague 7, Czech Republic. Electronic address: cristina.oancea@advacam.cz
245    10
$a Dosimetric and temporal beam characterization of individual pulses in FLASH radiotherapy using Timepix3 pixelated detector placed out-of-field / $c C. Oancea, K. Sykorova, J. Jakubek, J. Pivec, F. Riemer, S. Worm, A. Bourgouin
520    9_
$a BACKGROUND: FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods used to measure the delivered number of pulses, investigate temporal structure of individual pulses and dose-per-pulse (DPP) based on secondary radiation particles produced in the experimental room. METHODS: A 20 MeV electron beam generated from a linear accelerator (LINAC) was delivered to a water phantom. Ultra-high dose-per-pulse electron beams were used with a dose-per-pulse ranging from ̴ 1 Gy to over 7 Gy. The pulse lengths ranged from 1.18 μs to 2.88 μs at a pulse rate frequency of 5 Hz. A semiconductor pixel detector Timepix3 was used to track single secondary particles. Measurements were performed in the air, while the detector was positioned out-of-field at a lateral distance of 200 cm parallel with the LINAC exit window. The dose deposited was measured along with the pulse length and the nanostructure of the pulse. RESULTS: The time of arrival (ToA) of single particles was measured with a resolution of 1.56 ns, while the deposited energy was measured with a resolution of several keV based on the Time over Threshold (ToT) value. The pulse count measured by the Timepix3 detector corresponded with the delivered values, which were measured using an in-flange integrating current transformer (ICT). A linear response (R2 = 0.999) was established between the delivered beam current and the measured dose at the detector position (orders of nGy). The difference between the average measured and delivered pulse length was ∼0.003(30) μs. CONCLUSION: This simple non-invasive method exhibits no limitations on the delivered DPP within the range used during this investigation.
650    12
$a radiometrie $x přístrojové vybavení $x metody $7 D011874
650    12
$a částice - urychlovače $7 D010315
650    12
$a celková dávka radioterapie $7 D011879
650    _2
$a časové faktory $7 D013997
650    _2
$a fantomy radiodiagnostické $7 D019047
650    _2
$a radioterapie $x přístrojové vybavení $7 D011878
655    _2
$a časopisecké články $7 D016428
700    1_
$a Sykorova, Katerina $u ADVACAM, U Pergamenky 12, 170 00 Prague 7, Czech Republic
700    1_
$a Jakubek, Jan $u ADVACAM, U Pergamenky 12, 170 00 Prague 7, Czech Republic
700    1_
$a Pivec, Jiri $u ADVACAM, U Pergamenky 12, 170 00 Prague 7, Czech Republic
700    1_
$a Riemer, Felix $u Deutsches Elektronen-Synchrotron DESY, Platanenallee 6, 15738 Zeuthen, Germany
700    1_
$a Worm, Steven $u Deutsches Elektronen-Synchrotron DESY, Platanenallee 6, 15738 Zeuthen, Germany
700    1_
$a Bourgouin, Alexandra $u Dosimetry for Radiation Therapy and Diagnostic Radiology, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig 38116, Germany; Metrology Research Center, National Research Council of Canada, 1200 Montreal Road, Ottawa, ON, K1A0R6, Canada
773    0_
$w MED00167391 $t Physica medica $x 1724-191X $g Roč. 129 (20241211), s. 104872
856    41
$u https://pubmed.ncbi.nlm.nih.gov/39667142 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250415 $b ABA008
991    __
$a 20250429135139 $b ABA008
999    __
$a ok $b bmc $g 2311663 $s 1247523
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2025 $b 129 $c - $d 104872 $e 20241211 $i 1724-191X $m Physica medica $n Phys Med $x MED00167391
LZP    __
$a Pubmed-20250415

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...