Je něco špatně v tomto záznamu ?
Evaluation of dimensional accuracy and density of dental structures manufactured by different technologies
Viktoria Rajtukova, Bibiana Ondrejová, Andrea Sinčák Konečná, Jana Hlubeňová, Radovan Hudák
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem
- MeSH
- 3D tisk MeSH
- dentální technologie * MeSH
- lidé MeSH
- přesnost dimenzionálního měření * MeSH
- výzkumný projekt MeSH
- záchovná stomatologie metody MeSH
- zubní materiály klasifikace terapeutické užití MeSH
- zubní náhrady částečné fixní * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
This study focuses on the fabrication and analysis of a total of 90 dental structures (metal parts of dental prostheses – coping, bridges) of 3 types made of cobalt-chromium alloy through different fabrication technologies which include casting, additive manufacturing by selective laser melting (SLM) and subtraction technology by CNC milling. The manufacturing accuracy analysis was carried out by comparing the nominal model and the actual model obtained by 3D scanning of the fabricated dental structures in GOM Inspect software. Density measurements were performed by helium-based gas pycnometry. The data obtained were statistically analysed and a statistically significant difference was confirmed between the subtraction and additive technology. Based on the available manufacturing technologies, materials and equipment used to fabricate the samples for this study, it can be concluded that dentures fabricated by 3D printing are more accurate than dental structures fabricated by milling or casting technology.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25010898
- 003
- CZ-PrNML
- 005
- 20251008103603.0
- 007
- ta
- 008
- 250422s2023 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14311/CTJ.2023.2.04 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Rajťúková, Viktória, $d 1985- $7 xx0331811 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
- 245 10
- $a Evaluation of dimensional accuracy and density of dental structures manufactured by different technologies / $c Viktoria Rajtukova, Bibiana Ondrejová, Andrea Sinčák Konečná, Jana Hlubeňová, Radovan Hudák
- 504 __
- $a Literatura
- 520 9_
- $a This study focuses on the fabrication and analysis of a total of 90 dental structures (metal parts of dental prostheses – coping, bridges) of 3 types made of cobalt-chromium alloy through different fabrication technologies which include casting, additive manufacturing by selective laser melting (SLM) and subtraction technology by CNC milling. The manufacturing accuracy analysis was carried out by comparing the nominal model and the actual model obtained by 3D scanning of the fabricated dental structures in GOM Inspect software. Density measurements were performed by helium-based gas pycnometry. The data obtained were statistically analysed and a statistically significant difference was confirmed between the subtraction and additive technology. Based on the available manufacturing technologies, materials and equipment used to fabricate the samples for this study, it can be concluded that dentures fabricated by 3D printing are more accurate than dental structures fabricated by milling or casting technology.
- 650 07
- $a lidé $7 D006801 $2 czmesh
- 650 07
- $a zubní materiály $x klasifikace $x terapeutické užití $7 D003764 $2 czmesh
- 650 07
- $a výzkumný projekt $7 D012107 $2 czmesh
- 650 07
- $a 3D tisk $7 D066330 $2 czmesh
- 650 17
- $a dentální technologie $7 D013674 $2 czmesh
- 650 07
- $a záchovná stomatologie $x metody $7 D003814 $2 czmesh
- 650 17
- $a zubní náhrady částečné fixní $7 D003830 $2 czmesh
- 650 17
- $a přesnost dimenzionálního měření $7 D061827 $2 czmesh
- 655 _7
- $a práce podpořená grantem $7 D013485 $2 czmesh
- 700 1_
- $a Ondrejová, Bibiána $7 _AN120858 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
- 700 1_
- $a Sinčák Konečná, Andrea $7 xx0310818 $u Department of Conservative and Prosthetic dentistry, Stomatological clinic, Louis Pasteur University Hospital, Košice, Slovakia
- 700 1_
- $a Hlubeňová, Jana $7 xx0331816 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
- 700 1_
- $a Hudák, Radovan $7 xx0077439 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
- 773 0_
- $t Lékař a technika $x 0301-5491 $g Roč. 53, č. 2 (2023), s. 52-56 $w MED00011033
- 856 41
- $u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y p $z 0
- 990 __
- $a 20250418131110 $b ABA008
- 991 __
- $a 20251008103550 $b ABA008
- 999 __
- $a ok $b bmc $g 2306549 $s 1247979
- BAS __
- $a 3
- BMC __
- $a 2023 $b 53 $c 2 $d 52-56 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
- LZP __
- $c NLK197 $d 20250902 $a NLK 2025-15/dk