• Je něco špatně v tomto záznamu ?

Evaluation of dimensional accuracy and density of dental structures manufactured by different technologies

Viktoria Rajtukova, Bibiana Ondrejová, Andrea Sinčák Konečná, Jana Hlubeňová, Radovan Hudák

. 2023 ; 53 (2) : 52-56.

Jazyk angličtina Země Česko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc25010898

This study focuses on the fabrication and analysis of a total of 90 dental structures (metal parts of dental prostheses – coping, bridges) of 3 types made of cobalt-chromium alloy through different fabrication technologies which include casting, additive manufacturing by selective laser melting (SLM) and subtraction technology by CNC milling. The manufacturing accuracy analysis was carried out by comparing the nominal model and the actual model obtained by 3D scanning of the fabricated dental structures in GOM Inspect software. Density measurements were performed by helium-based gas pycnometry. The data obtained were statistically analysed and a statistically significant difference was confirmed between the subtraction and additive technology. Based on the available manufacturing technologies, materials and equipment used to fabricate the samples for this study, it can be concluded that dentures fabricated by 3D printing are more accurate than dental structures fabricated by milling or casting technology.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc25010898
003      
CZ-PrNML
005      
20251008103603.0
007      
ta
008      
250422s2023 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2023.2.04 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Rajťúková, Viktória, $d 1985- $7 xx0331811 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
245    10
$a Evaluation of dimensional accuracy and density of dental structures manufactured by different technologies / $c Viktoria Rajtukova, Bibiana Ondrejová, Andrea Sinčák Konečná, Jana Hlubeňová, Radovan Hudák
504    __
$a Literatura
520    9_
$a This study focuses on the fabrication and analysis of a total of 90 dental structures (metal parts of dental prostheses – coping, bridges) of 3 types made of cobalt-chromium alloy through different fabrication technologies which include casting, additive manufacturing by selective laser melting (SLM) and subtraction technology by CNC milling. The manufacturing accuracy analysis was carried out by comparing the nominal model and the actual model obtained by 3D scanning of the fabricated dental structures in GOM Inspect software. Density measurements were performed by helium-based gas pycnometry. The data obtained were statistically analysed and a statistically significant difference was confirmed between the subtraction and additive technology. Based on the available manufacturing technologies, materials and equipment used to fabricate the samples for this study, it can be concluded that dentures fabricated by 3D printing are more accurate than dental structures fabricated by milling or casting technology.
650    07
$a lidé $7 D006801 $2 czmesh
650    07
$a zubní materiály $x klasifikace $x terapeutické užití $7 D003764 $2 czmesh
650    07
$a výzkumný projekt $7 D012107 $2 czmesh
650    07
$a 3D tisk $7 D066330 $2 czmesh
650    17
$a dentální technologie $7 D013674 $2 czmesh
650    07
$a záchovná stomatologie $x metody $7 D003814 $2 czmesh
650    17
$a zubní náhrady částečné fixní $7 D003830 $2 czmesh
650    17
$a přesnost dimenzionálního měření $7 D061827 $2 czmesh
655    _7
$a práce podpořená grantem $7 D013485 $2 czmesh
700    1_
$a Ondrejová, Bibiána $7 _AN120858 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
700    1_
$a Sinčák Konečná, Andrea $7 xx0310818 $u Department of Conservative and Prosthetic dentistry, Stomatological clinic, Louis Pasteur University Hospital, Košice, Slovakia
700    1_
$a Hlubeňová, Jana $7 xx0331816 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
700    1_
$a Hudák, Radovan $7 xx0077439 $u Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Košice, Slovakia
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 53, č. 2 (2023), s. 52-56 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
910    __
$a ABA008 $b B 1367 $c 1071 b $y p $z 0
990    __
$a 20250418131110 $b ABA008
991    __
$a 20251008103550 $b ABA008
999    __
$a ok $b bmc $g 2306549 $s 1247979
BAS    __
$a 3
BMC    __
$a 2023 $b 53 $c 2 $d 52-56 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$c NLK197 $d 20250902 $a NLK 2025-15/dk

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...