Influence of the ARC welding related electromagnetic field on pacemakers

Tomáš Souček, Aleš Richter, Mahdi Abdel Haq

. 2023 ; 53 (2) : 57-61.

Status minimal Language English Country Czech Republic

The patients with implanted pacemaker or cardioverter-defibrillator are exposed to a certain risk of affecting this device by surrounding electromagnetic field. There are many sources of potential risky electromagnetic fields, arc welding is definitely one of them. The aim of this article is to present research focused on analysis of the pacemaker function during welding. There were performed in-vitro measurements with 9 pacemakers during metal inert gas (MIG) and tungsten inert gas (TIG) method arc welding. The responses of pacemakers were monitored by communication via programmer. Based on these measurements there are proposed safe distances from the main parts of welding machines, and also conditions and instructions for arc welding by patients with pacemakers. To ensure patient safety, patients should maintain suggested safe distances, use direct current with minimal possible amplitude, and weld in short intervals. Additionally, their pacemakers should be set to bipolar configuration.

References provided by Crossref.org

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc25010902
003      
CZ-PrNML
005      
20250422124006.0
007      
ta
008      
250422s2023 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2023.2.05 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Souček, Tomáš $7 osa20221167940 $u Faculty of Health Studies, Technical University of Liberec, Liberec, Czech Republic $u Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic
245    10
$a Influence of the ARC welding related electromagnetic field on pacemakers / $c Tomáš Souček, Aleš Richter, Mahdi Abdel Haq
504    __
$a Literatura
520    9_
$a The patients with implanted pacemaker or cardioverter-defibrillator are exposed to a certain risk of affecting this device by surrounding electromagnetic field. There are many sources of potential risky electromagnetic fields, arc welding is definitely one of them. The aim of this article is to present research focused on analysis of the pacemaker function during welding. There were performed in-vitro measurements with 9 pacemakers during metal inert gas (MIG) and tungsten inert gas (TIG) method arc welding. The responses of pacemakers were monitored by communication via programmer. Based on these measurements there are proposed safe distances from the main parts of welding machines, and also conditions and instructions for arc welding by patients with pacemakers. To ensure patient safety, patients should maintain suggested safe distances, use direct current with minimal possible amplitude, and weld in short intervals. Additionally, their pacemakers should be set to bipolar configuration.
700    1_
$a Richter, Aleš, $d 1957- $7 xx0000450 $u Faculty of Health Studies, Technical University of Liberec, Liberec, Czech Republic
700    1_
$a Abdel-Haq, Mahdi $u Staatliche Studienakademie Bautzen, Berufsakademie Sachsen, Bautzen, Germany
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 53, č. 2 (2023), s. 57-61 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
910    __
$a ABA008 $b B 1367 $c 1071 b $y 0 $z 0
990    __
$a 20250418131110 $b ABA008
991    __
$a 20250422130132 $b ABA008
999    __
$a min $b bmc $g 2306553 $s 1247983
BAS    __
$a 3
BMC    __
$a 2023 $b 53 $c 2 $d 57-61 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$a NLK 2025-15/dk

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...