Effect of electrode abelt used for lung monitoring with electrical impedance tomography on tidal volume in healthy subjects

Kristyna Koldova, Tereza Blažková

. 2024 ; 54 (3) : 77-81.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc25010970

Electrical impedance tomography is a radiation free, non-invasive lung monitoring method that is increasingly coming to the forefront of the interest of researchers and clinicians. The most frequently used EIT system PulmoVista 500 (Dräger Medical, Germany) uses stiff silicone electrode belt that is applied around the patient’s thorax to monitor the distribution of ventilation. To achieve proper electrode-skin connection and obtain high-quality signal, the electrode belt needs to be placed tightly at the level of 4th to 6th intercostal space. There is a possibility that tightly placed belt affects the compliance of the chest wall, tidal volume, and respiratory effort of the patient. In this study, we monitored tidal volumes using spirometer in 10 healthy, spontaneously breathing volunteers with and without the electrode belt applied around the thorax. Potentially clinically significant, but not statistically significant changes occurred in 70% of the subjects during calm breathing and in 90% of the subjects during forced breathing. The study did not determine whether the use of the electrode belt increases or decreases the value of tidal volume. However, when monitoring lung ventilation with EIT system, the possible influence of the stiff electrode belt on chest wall compliance and tidal volumes should be considered.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc25010970
003      
CZ-PrNML
005      
20250811160004.0
007      
ta
008      
250423s2024 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2024.3.01 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Koldová, Kristýna $7 xx0228396 $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
245    10
$a Effect of electrode abelt used for lung monitoring with electrical impedance tomography on tidal volume in healthy subjects / $c Kristyna Koldova, Tereza Blažková
504    __
$a Literatura
520    9_
$a Electrical impedance tomography is a radiation free, non-invasive lung monitoring method that is increasingly coming to the forefront of the interest of researchers and clinicians. The most frequently used EIT system PulmoVista 500 (Dräger Medical, Germany) uses stiff silicone electrode belt that is applied around the patient’s thorax to monitor the distribution of ventilation. To achieve proper electrode-skin connection and obtain high-quality signal, the electrode belt needs to be placed tightly at the level of 4th to 6th intercostal space. There is a possibility that tightly placed belt affects the compliance of the chest wall, tidal volume, and respiratory effort of the patient. In this study, we monitored tidal volumes using spirometer in 10 healthy, spontaneously breathing volunteers with and without the electrode belt applied around the thorax. Potentially clinically significant, but not statistically significant changes occurred in 70% of the subjects during calm breathing and in 90% of the subjects during forced breathing. The study did not determine whether the use of the electrode belt increases or decreases the value of tidal volume. However, when monitoring lung ventilation with EIT system, the possible influence of the stiff electrode belt on chest wall compliance and tidal volumes should be considered.
650    17
$a tomografie $7 D014054 $2 czmesh
650    07
$a lidé $7 D006801 $2 czmesh
650    17
$a dýchání $7 D012119 $2 czmesh
650    07
$a elektrická impedance $7 D017097 $2 czmesh
650    07
$a dýchání $7 D012119 $2 czmesh
650    07
$a elektrody $7 D004566 $2 czmesh
650    07
$a spirometrie $7 D013147 $2 czmesh
650    07
$a prospektivní studie $7 D011446 $2 czmesh
700    1_
$a Blažková, Tereza $7 _AN122433 $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 54, č. 3 (2024), s. 77-81 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/issue/archive $y stránka časopisu
910    __
$a ABA008 $b B 1367 $c 1071 b $y p $z 0
990    __
$a 20250418131110 $b ABA008
991    __
$a 20250811160658 $b ABA008
999    __
$a ok $b bmc $g 2307257 $s 1248052
BAS    __
$a 3
BMC    __
$a 2024 $b 54 $c 3 $d 77-81 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$c NLK109 $d 20250811 $a NLK 2025-15/dk

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...