A comparative study between CT angiography and flow parameters in hemodynamic phantom of carotid stenosis evaluated by duplex sonography

A. Seidlová, N. Svoboda, R. Voldřich, P. Kešnerová, R. Matějka, D. Pakizer, D. Školoudík, D. Netuka

. 2025 ; 11 (1) : 29. [pub] 20250617

Status neindexováno Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc25014155

Grantová podpora
NU22-04-00389 Ministerstvo Zdravotnictví Ceské Republiky
NU22-04-00389 Ministerstvo Zdravotnictví Ceské Republiky

BACKGROUND: The use of 3D-printed hemodynamic phantom of a stenotic carotid artery has not been extensively investigated. Our study aims to address this gap by exploring the correlation between CTA and flow parameters in hemodynamic phantom. METHODS: Patients with carotid stenosis were included in a prospective study. A realistic phantoms of carotid artery stenoses were 3D-printed based on CT angiography. Stenosis severity and hemodynamic flow parameters in the phantom evaluated using duplex sonography were correlated with CTA. The primary outcome was to compare the evaluation of the percentage of stenosis based on the measurement of diameter reduction and area reduction of the carotid artery among CTA, a 3D model constructed from CTA data, and ultrasound measurement of stenosis percentage within the 3D printed phantom. The secondary outcome was to determine whether the percentage of stenosis measured by ultrasound in B-mode or ultrasound-measured flow velocities (PSV, EDV) better correlates with the stenosis percentage derived from CTA and the phantom. RESULTS: The study included 95 subjects (average age 71 years, 75% male) with carotid stenosis, 39% were symptomatic. Significant correlations were found between ultrasound B-Mode findings on the phantom and CTA, with the strongest correlations for area reduction (Spearman r = 0.615, p < 0.0001) and diameter reduction (Spearman r = 0.465, p < 0.0001). The most robust correlation between PSV and EDV in stenosis and the percentage of stenosis was identified between PSV in stenosis and the percentage of stenosis by diameter reduction, as evaluated through ultrasound. The Spearman correlation coefficient revealed a relatively strong correlation, with a value of r = 0.444 (p < 0.0001), and the Kendall Tau correlation coefficient also demonstrated significance, with a value of r = 0.302 (p < 0.0001). CONCLUSIONS: A significant correlation between CTA and duplex sonography measurements on the carotid phantom was demostrated, suggesting the potential utilization of the phantom in testing hemodynamic parameters of carotid stenosis.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25014155
003      
CZ-PrNML
005      
20250905141512.0
007      
ta
008      
250701s2025 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1186/s41205-025-00271-0 $2 doi
035    __
$a (PubMed)40526268
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Seidlová, Anna $u First Faculty of Medicine, Charles University, Katerinská 32, Prague 2, 121 08, Czech Republic $u Department of Neurosurgery and Neurooncology, First Faculty of Medicine, Charles University, Military University Hospital, U Vojenské nemocnice 1200, Prague 6, 169 02, Czech Republic
245    12
$a A comparative study between CT angiography and flow parameters in hemodynamic phantom of carotid stenosis evaluated by duplex sonography / $c A. Seidlová, N. Svoboda, R. Voldřich, P. Kešnerová, R. Matějka, D. Pakizer, D. Školoudík, D. Netuka
520    9_
$a BACKGROUND: The use of 3D-printed hemodynamic phantom of a stenotic carotid artery has not been extensively investigated. Our study aims to address this gap by exploring the correlation between CTA and flow parameters in hemodynamic phantom. METHODS: Patients with carotid stenosis were included in a prospective study. A realistic phantoms of carotid artery stenoses were 3D-printed based on CT angiography. Stenosis severity and hemodynamic flow parameters in the phantom evaluated using duplex sonography were correlated with CTA. The primary outcome was to compare the evaluation of the percentage of stenosis based on the measurement of diameter reduction and area reduction of the carotid artery among CTA, a 3D model constructed from CTA data, and ultrasound measurement of stenosis percentage within the 3D printed phantom. The secondary outcome was to determine whether the percentage of stenosis measured by ultrasound in B-mode or ultrasound-measured flow velocities (PSV, EDV) better correlates with the stenosis percentage derived from CTA and the phantom. RESULTS: The study included 95 subjects (average age 71 years, 75% male) with carotid stenosis, 39% were symptomatic. Significant correlations were found between ultrasound B-Mode findings on the phantom and CTA, with the strongest correlations for area reduction (Spearman r = 0.615, p < 0.0001) and diameter reduction (Spearman r = 0.465, p < 0.0001). The most robust correlation between PSV and EDV in stenosis and the percentage of stenosis was identified between PSV in stenosis and the percentage of stenosis by diameter reduction, as evaluated through ultrasound. The Spearman correlation coefficient revealed a relatively strong correlation, with a value of r = 0.444 (p < 0.0001), and the Kendall Tau correlation coefficient also demonstrated significance, with a value of r = 0.302 (p < 0.0001). CONCLUSIONS: A significant correlation between CTA and duplex sonography measurements on the carotid phantom was demostrated, suggesting the potential utilization of the phantom in testing hemodynamic parameters of carotid stenosis.
590    __
$a NEINDEXOVÁNO
655    _2
$a časopisecké články $7 D016428
700    1_
$a Svoboda, Norbert $u Department of Neurosurgery and Neurooncology, First Faculty of Medicine, Charles University, Military University Hospital, U Vojenské nemocnice 1200, Prague 6, 169 02, Czech Republic
700    1_
$a Voldřich, Richard $u Department of Neurosurgery and Neurooncology, First Faculty of Medicine, Charles University, Military University Hospital, U Vojenské nemocnice 1200, Prague 6, 169 02, Czech Republic
700    1_
$a Kešnerová, Petra $u Department of Neurology, 2nd Faculty of Medicine, Charles University, University Hospital Motol, V Úvalu 84, Prague 5, 150 06, Czech Republic
700    1_
$a Matějka, Roman $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, Kladno, 27201, Czech Republic
700    1_
$a Pakizer, David $u Centre for Health Research, Department of Clinical Neurosciences, Faculty of Medicine, University of Ostrava, Syllabova 19, Ostrava, 703 00, Czech Republic
700    1_
$a Školoudík, David $u Centre for Health Research, Department of Clinical Neurosciences, Faculty of Medicine, University of Ostrava, Syllabova 19, Ostrava, 703 00, Czech Republic
700    1_
$a Netuka, David $u Department of Neurosurgery and Neurooncology, First Faculty of Medicine, Charles University, Military University Hospital, U Vojenské nemocnice 1200, Prague 6, 169 02, Czech Republic. davidnetuka7@gmail.com
773    0_
$w MED00216582 $t 3D printing in medicine $x 2365-6271 $g Roč. 11, č. 1 (2025), s. 29
856    41
$u https://pubmed.ncbi.nlm.nih.gov/40526268 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250701 $b ABA008
991    __
$a 20250905141500 $b ABA008
999    __
$a ok $b bmc $g 2387982 $s 1251275
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2025 $b 11 $c 1 $d 29 $e 20250617 $i 2365-6271 $m 3D printing in medicine $n 3D print. medicine $x MED00216582
GRA    __
$a NU22-04-00389 $p Ministerstvo Zdravotnictví Ceské Republiky
GRA    __
$a NU22-04-00389 $p Ministerstvo Zdravotnictví Ceské Republiky
LZP    __
$a Pubmed-20250701

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...