-
Je něco špatně v tomto záznamu ?
Acute effects of isometric conditioning activity with different distribution contraction on countermovement jump performance in resistance trained participants
J. Jarosz, M. Drozd, D. Gawel, M. Wilk, J. Helbin, M. Krzysztofik
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2011
Free Medical Journals
od 2011
Nature Open Access
od 2011-12-01
PubMed Central
od 2011
Europe PubMed Central
od 2011
ProQuest Central
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Health & Medicine (ProQuest)
od 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2011
Springer Nature OA/Free Journals
od 2011-12-01
- MeSH
- dospělí MeSH
- isometrická kontrakce * fyziologie MeSH
- kosterní svaly * fyziologie MeSH
- lidé MeSH
- mladý dospělý MeSH
- odporový trénink * metody MeSH
- sportovní výkon * fyziologie MeSH
- svalová síla fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
The aim of this study was to compare the effects of 3 sets of isometric conditioning activity (ICA), each with an equal total duration (9 s per set) but with different distributions contractions, on force production during ICA and subsequent countermovement jump (CMJ) performance. Fifteen resistance-trained males participated in this study (age: 22.1 ± 2.4 years; body mass: 85.1 ± 9.7 kg; height: 181.3 ± 6.5 cm; relative one-repetition maximum (1RM) in back squat: 1.59 ± 0.32 kg/kg of body mass). Participants completed 3 conditions, each consisting of ICA in the half-back squat with a pushing isometric muscle action (PIMA) position at a 120-degree knee angle against an immovable barbell, differing in repetition distribution: 3 sets of 9 repetitions lasting 1 s each (SUST-1), 3 sets of 3 repetitions lasting 3 s each (SUST-3), 3 sets of single repetitions lasting 9 s (SUST-9), and a control condition (CTRL) without ICA. A 1-minute rest was allowed between sets. Approximately 3 min pre-ICA and at 15 s, 3-, 6-, 9-, and 12-minutes post-ICA, the CMJ performance was assessed. Moreover, peak force (PF) production, and force generated at 100 (Force100) and 200 ms (Force200) during each ICA were evaluated. A two-way repeated measures ANOVA indicated a main effect of time on CMJ height (F = 2.674; p = 0.029; ηp2=0.171) but did not show significant differences between conditions (F = 0.934; p = 0.434; ηp2=0.067) or interactions (F = 0.826; p = 0.648; ηp2=0.060). Post-hoc comparisons indicated a significant decrease in CMJ height at the 9th minute compared to the 3rd minute (35.7 ± 5.6 cm vs. 36.8 ± 5.5 cm post-CA; d = 0.161; p = 0.048). In addition, no significant interactions or main effects were found for CMJ contraction time, PF and Force100 during ICA. However, a main effect of condition was demonstrated on Force200 (F = 19.181; p < 0.001; ηp2= 0.013). Post-hoc comparisons revealed higher Force200 values in SUST-1 (mean difference [MD] = 549 ± 137 N; d = 1.049; p < 0.001) and SUST-3 (MD = 348 ± 112 N; d = 0.665; p = 0.002) compared to the SUST-9 condition. None of the ICAs used in the present study had any effect on the CMJ performance. However, the significantly higher Force200 values noted in the SUST-1, and SUST-3 conditions compared to the SUST-9 condition suggest that the specific distributions of isometric contraction influence the force generated during their execution.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25015731
- 003
- CZ-PrNML
- 005
- 20250731091208.0
- 007
- ta
- 008
- 250708s2025 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-025-02126-4 $2 doi
- 035 __
- $a (PubMed)40374844
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Jarosz, Jakub $u Institute of Sport Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland. j.jarosz@awf.katowice.pl
- 245 10
- $a Acute effects of isometric conditioning activity with different distribution contraction on countermovement jump performance in resistance trained participants / $c J. Jarosz, M. Drozd, D. Gawel, M. Wilk, J. Helbin, M. Krzysztofik
- 520 9_
- $a The aim of this study was to compare the effects of 3 sets of isometric conditioning activity (ICA), each with an equal total duration (9 s per set) but with different distributions contractions, on force production during ICA and subsequent countermovement jump (CMJ) performance. Fifteen resistance-trained males participated in this study (age: 22.1 ± 2.4 years; body mass: 85.1 ± 9.7 kg; height: 181.3 ± 6.5 cm; relative one-repetition maximum (1RM) in back squat: 1.59 ± 0.32 kg/kg of body mass). Participants completed 3 conditions, each consisting of ICA in the half-back squat with a pushing isometric muscle action (PIMA) position at a 120-degree knee angle against an immovable barbell, differing in repetition distribution: 3 sets of 9 repetitions lasting 1 s each (SUST-1), 3 sets of 3 repetitions lasting 3 s each (SUST-3), 3 sets of single repetitions lasting 9 s (SUST-9), and a control condition (CTRL) without ICA. A 1-minute rest was allowed between sets. Approximately 3 min pre-ICA and at 15 s, 3-, 6-, 9-, and 12-minutes post-ICA, the CMJ performance was assessed. Moreover, peak force (PF) production, and force generated at 100 (Force100) and 200 ms (Force200) during each ICA were evaluated. A two-way repeated measures ANOVA indicated a main effect of time on CMJ height (F = 2.674; p = 0.029; ηp2=0.171) but did not show significant differences between conditions (F = 0.934; p = 0.434; ηp2=0.067) or interactions (F = 0.826; p = 0.648; ηp2=0.060). Post-hoc comparisons indicated a significant decrease in CMJ height at the 9th minute compared to the 3rd minute (35.7 ± 5.6 cm vs. 36.8 ± 5.5 cm post-CA; d = 0.161; p = 0.048). In addition, no significant interactions or main effects were found for CMJ contraction time, PF and Force100 during ICA. However, a main effect of condition was demonstrated on Force200 (F = 19.181; p < 0.001; ηp2= 0.013). Post-hoc comparisons revealed higher Force200 values in SUST-1 (mean difference [MD] = 549 ± 137 N; d = 1.049; p < 0.001) and SUST-3 (MD = 348 ± 112 N; d = 0.665; p = 0.002) compared to the SUST-9 condition. None of the ICAs used in the present study had any effect on the CMJ performance. However, the significantly higher Force200 values noted in the SUST-1, and SUST-3 conditions compared to the SUST-9 condition suggest that the specific distributions of isometric contraction influence the force generated during their execution.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a isometrická kontrakce $x fyziologie $7 D007537
- 650 12
- $a odporový trénink $x metody $7 D055070
- 650 _2
- $a mladý dospělý $7 D055815
- 650 _2
- $a dospělí $7 D000328
- 650 12
- $a kosterní svaly $x fyziologie $7 D018482
- 650 12
- $a sportovní výkon $x fyziologie $7 D054874
- 650 _2
- $a svalová síla $x fyziologie $7 D053580
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Drozd, Milosz $u Institute of Sport Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland
- 700 1_
- $a Gawel, Dawid $u Institute of Sport Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland
- 700 1_
- $a Wilk, Michal $u Institute of Sport Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland
- 700 1_
- $a Helbin, Jonatan $u Institute of Sport Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland
- 700 1_
- $a Krzysztofik, Michal $u Institute of Sport Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland $u Department of Sports Games, Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 15, č. 1 (2025), s. 16960
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/40374844 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20250708 $b ABA008
- 991 __
- $a 20250731091203 $b ABA008
- 999 __
- $a ok $b bmc $g 2366525 $s 1252856
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2025 $b 15 $c 1 $d 16960 $e 20250515 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20250708