Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application

E. Pehlivan, J. Džugan, J. Fojt, R. Sedláček, S. Rzepa, M. Daniel

. 2020 ; 13 (22) : . [pub] 20201116

Status minimální Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc25025912

Grantová podpora
SGS19/155/OHK2/3T/12 České Vysoké Učení Technické v Praze
TF02000067 Technologická Agentura České Republiky
NU20-06-00424 MZ0 CEP - Centrální evidence projektů

Additive manufacturing technologies allow producing a regular three-dimensional mesh of interconnected struts that form an open-cell porous structure. Regular porous structures have been used in the orthopedic industry due to outstanding bone anchoring. The aim of the study was to determine how the postprocessing influences the mechanical properties of porous structures made of titanium alloy CL 41TI ELI. The effect of hot isostatic pressing (HIP) as a method of increasing microstructural integrity was investigated here. The influence of surface etching (SE) technique, which was applied to the porous structure for cleaning unmelted titanium powder particles on the surface of connectors from the inner surfaces of a porous structure, was examined in this study. Mechanical properties were investigated by means of compression tests. The results point out that HIP has a minor effect on the mechanical behavior of considered porous structures. The SE is an effective method to clean the surface of a porous structure, which is very important in the case of biomedical applications when loose powder can cause serious health problems. Another effect of the SE is also the strut thickness reduction. Reducing strut thickness of a porous structure with the surface etching decreases its stiffness to the same extent as predicted by the relative density theoretical model but did not result in structural damage.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25025912
003      
CZ-PrNML
005      
20251212152604.0
007      
ta
008      
251210s2020 xr f 000 0|eng||
024    7_
$a 10.3390/ma13225167 $2 doi
035    __
$a (PubMed)33207787
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Pehlivan, Eren $u Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical Universityin Prague, Technická 1902/4, 16000 Prague, Czech Republic $1 https://orcid.org/0000000246966826
245    10
$a Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application / $c E. Pehlivan, J. Džugan, J. Fojt, R. Sedláček, S. Rzepa, M. Daniel
520    9_
$a Additive manufacturing technologies allow producing a regular three-dimensional mesh of interconnected struts that form an open-cell porous structure. Regular porous structures have been used in the orthopedic industry due to outstanding bone anchoring. The aim of the study was to determine how the postprocessing influences the mechanical properties of porous structures made of titanium alloy CL 41TI ELI. The effect of hot isostatic pressing (HIP) as a method of increasing microstructural integrity was investigated here. The influence of surface etching (SE) technique, which was applied to the porous structure for cleaning unmelted titanium powder particles on the surface of connectors from the inner surfaces of a porous structure, was examined in this study. Mechanical properties were investigated by means of compression tests. The results point out that HIP has a minor effect on the mechanical behavior of considered porous structures. The SE is an effective method to clean the surface of a porous structure, which is very important in the case of biomedical applications when loose powder can cause serious health problems. Another effect of the SE is also the strut thickness reduction. Reducing strut thickness of a porous structure with the surface etching decreases its stiffness to the same extent as predicted by the relative density theoretical model but did not result in structural damage.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Džugan, Jan $u Mechanical Testing and Thermophysical Measurement Department, COMTES FHT a.s., Průmyslová 995, 33441 Dobrany, Czech Republic $1 https://orcid.org/0000000189969341 $7 mzk2014827214
700    1_
$a Fojt, Jaroslav $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 5, 16628 Prague, Czech Republic $1 https://orcid.org/0000000214255464
700    1_
$a Sedláček, Radek $u Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical Universityin Prague, Technická 1902/4, 16000 Prague, Czech Republic $1 https://orcid.org/0000000184685921 $7 ntka173960
700    1_
$a Rzepa, Sylwia $u Mechanical Testing and Thermophysical Measurement Department, COMTES FHT a.s., Průmyslová 995, 33441 Dobrany, Czech Republic $1 https://orcid.org/0000000335380771
700    1_
$a Daniel, Matej $u Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical Universityin Prague, Technická 1902/4, 16000 Prague, Czech Republic $1 https://orcid.org/0000000305321965 $7 xx0029605
773    0_
$w MED00194074 $t Materials (Basel) $x 1996-1944 $g Roč. 13, č. 22 (2020), s.
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33207787 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y -
990    __
$a 20251210 $b ABA008
999    __
$a min $b bmc $g 2446414 $s 1264110
BAS    __
$a 3
BAS    __
$a PreBMC-PubMed-not-MEDLINE
BMC    __
$a 2020 $b 13 $c 22 $e 20201116 $i 1996-1944 $m Materials (Basel, Switzerland) $n Materials (Basel) $x MED00194074
GRA    __
$a SGS19/155/OHK2/3T/12 $p České Vysoké Učení Technické v Praze
GRA    __
$a TF02000067 $p Technologická Agentura České Republiky
GRA    __
$a NU20-06-00424 $p MZ0
LZP    __
$a AZV-2023-Pubmed-20251210

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...