Je něco špatně v tomto záznamu ?
Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application
E. Pehlivan, J. Džugan, J. Fojt, R. Sedláček, S. Rzepa, M. Daniel
Status minimální Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
Grantová podpora
SGS19/155/OHK2/3T/12
České Vysoké Učení Technické v Praze
TF02000067
Technologická Agentura České Republiky
NU20-06-00424
MZ0
CEP - Centrální evidence projektů
NLK
Freely Accessible Science Journals
od 2008
PubMed Central
od 2008
Europe PubMed Central
od 2008
ProQuest Central
od 2008-01-01
Open Access Digital Library
od 2008-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2008
PubMed
33207787
DOI
10.3390/ma13225167
Knihovny.cz E-zdroje
- Publikační typ
- časopisecké články MeSH
Additive manufacturing technologies allow producing a regular three-dimensional mesh of interconnected struts that form an open-cell porous structure. Regular porous structures have been used in the orthopedic industry due to outstanding bone anchoring. The aim of the study was to determine how the postprocessing influences the mechanical properties of porous structures made of titanium alloy CL 41TI ELI. The effect of hot isostatic pressing (HIP) as a method of increasing microstructural integrity was investigated here. The influence of surface etching (SE) technique, which was applied to the porous structure for cleaning unmelted titanium powder particles on the surface of connectors from the inner surfaces of a porous structure, was examined in this study. Mechanical properties were investigated by means of compression tests. The results point out that HIP has a minor effect on the mechanical behavior of considered porous structures. The SE is an effective method to clean the surface of a porous structure, which is very important in the case of biomedical applications when loose powder can cause serious health problems. Another effect of the SE is also the strut thickness reduction. Reducing strut thickness of a porous structure with the surface etching decreases its stiffness to the same extent as predicted by the relative density theoretical model but did not result in structural damage.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25025912
- 003
- CZ-PrNML
- 005
- 20251212152604.0
- 007
- ta
- 008
- 251210s2020 xr f 000 0|eng||
- 024 7_
- $a 10.3390/ma13225167 $2 doi
- 035 __
- $a (PubMed)33207787
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Pehlivan, Eren $u Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical Universityin Prague, Technická 1902/4, 16000 Prague, Czech Republic $1 https://orcid.org/0000000246966826
- 245 10
- $a Post-Processing Treatment Impact on Mechanical Properties of SLM Deposited Ti-6Al-4 V Porous Structure for Biomedical Application / $c E. Pehlivan, J. Džugan, J. Fojt, R. Sedláček, S. Rzepa, M. Daniel
- 520 9_
- $a Additive manufacturing technologies allow producing a regular three-dimensional mesh of interconnected struts that form an open-cell porous structure. Regular porous structures have been used in the orthopedic industry due to outstanding bone anchoring. The aim of the study was to determine how the postprocessing influences the mechanical properties of porous structures made of titanium alloy CL 41TI ELI. The effect of hot isostatic pressing (HIP) as a method of increasing microstructural integrity was investigated here. The influence of surface etching (SE) technique, which was applied to the porous structure for cleaning unmelted titanium powder particles on the surface of connectors from the inner surfaces of a porous structure, was examined in this study. Mechanical properties were investigated by means of compression tests. The results point out that HIP has a minor effect on the mechanical behavior of considered porous structures. The SE is an effective method to clean the surface of a porous structure, which is very important in the case of biomedical applications when loose powder can cause serious health problems. Another effect of the SE is also the strut thickness reduction. Reducing strut thickness of a porous structure with the surface etching decreases its stiffness to the same extent as predicted by the relative density theoretical model but did not result in structural damage.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Džugan, Jan $u Mechanical Testing and Thermophysical Measurement Department, COMTES FHT a.s., Průmyslová 995, 33441 Dobrany, Czech Republic $1 https://orcid.org/0000000189969341 $7 mzk2014827214
- 700 1_
- $a Fojt, Jaroslav $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 5, 16628 Prague, Czech Republic $1 https://orcid.org/0000000214255464
- 700 1_
- $a Sedláček, Radek $u Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical Universityin Prague, Technická 1902/4, 16000 Prague, Czech Republic $1 https://orcid.org/0000000184685921 $7 ntka173960
- 700 1_
- $a Rzepa, Sylwia $u Mechanical Testing and Thermophysical Measurement Department, COMTES FHT a.s., Průmyslová 995, 33441 Dobrany, Czech Republic $1 https://orcid.org/0000000335380771
- 700 1_
- $a Daniel, Matej $u Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical Universityin Prague, Technická 1902/4, 16000 Prague, Czech Republic $1 https://orcid.org/0000000305321965 $7 xx0029605
- 773 0_
- $w MED00194074 $t Materials (Basel) $x 1996-1944 $g Roč. 13, č. 22 (2020), s.
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33207787 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y -
- 990 __
- $a 20251210 $b ABA008
- 999 __
- $a min $b bmc $g 2446414 $s 1264110
- BAS __
- $a 3
- BAS __
- $a PreBMC-PubMed-not-MEDLINE
- BMC __
- $a 2020 $b 13 $c 22 $e 20201116 $i 1996-1944 $m Materials (Basel, Switzerland) $n Materials (Basel) $x MED00194074
- GRA __
- $a SGS19/155/OHK2/3T/12 $p České Vysoké Učení Technické v Praze
- GRA __
- $a TF02000067 $p Technologická Agentura České Republiky
- GRA __
- $a NU20-06-00424 $p MZ0
- LZP __
- $a AZV-2023-Pubmed-20251210