• Je něco špatně v tomto záznamu ?

Spolehlivost užití přístroje Fertility indicator pro určení plodného a neplodného období u ženy
[Reliability of using the Fertility Indicator as a tool for the determination of the fertile and infertile period in a woman]

J. Dostál, I. Oborná, M. Kudela

. 1999 ; Roč. 8 (č. 5) : s. 237-240.

Jazyk čeština Země Česko

Typ dokumentu srovnávací studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc99021877

We have evaluated reliability of the Fertility Indicator for the determination of the fertile and infertile periods of female menstrual cycle. Our results show that women are able, after proper instruction, to distinguish between the patterns witnessing of fertile or infertile period. F1 is a good aid, but it is not 100 % reliable. For a layman use it is always necessary to assume the possibility of a wrong interpretation of findings, especially by beginners or when the recommended procedure is not strictly observed. In our study the device achieved the sensitivity of 31.3 % for the determination of the fertile period and the specificity of 81.8 %for the infertile period (for the days between the 7th and the25th day of menstrual cycle). Evaluating the whole cycle (from the first to the 28th day) the test specificity for the infertile period is 90 % when read by a volunteer and 93 % when read by a trained staff member. We have observed a high correlation of the evaluation by volunteers with that done by a trained staff member. On the basis of our testing we can recommend the device as a suitable complementary aid for the natural methods of planned parenthood.

Reliability of using the Fertility Indicator as a tool for the determination of the fertile and infertile period in a woman

Spolehlivost užití přístroje Fertility indicator pro určení plodného a neplodného období u ženy = Reliability of using the Fertility Indicator as a tool for the determination of the fertile and infertile period in a woman /

Bibliografie atd.

Lit: 10

Bibliografie atd.

Souhrn: eng

000      
00000naa a2200000 a 4500
001      
bmc99021877
003      
CZ-PrNML
005      
20170314123756.0
008      
991200s1999 xr u cze||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Dostál, Jiří, $d 1961- $4 aut $7 xx0064687
245    10
$a Spolehlivost užití přístroje Fertility indicator pro určení plodného a neplodného období u ženy = $b Reliability of using the Fertility Indicator as a tool for the determination of the fertile and infertile period in a woman / $c J. Dostál, I. Oborná, M. Kudela
246    11
$a Reliability of using the Fertility Indicator as a tool for the determination of the fertile and infertile period in a woman
314    __
$a FN. Gynekologicko-porodnická klinika, Olomouc, CZ
504    __
$a Lit: 10
504    __
$a Souhrn: eng
520    9_
$a We have evaluated reliability of the Fertility Indicator for the determination of the fertile and infertile periods of female menstrual cycle. Our results show that women are able, after proper instruction, to distinguish between the patterns witnessing of fertile or infertile period. F1 is a good aid, but it is not 100 % reliable. For a layman use it is always necessary to assume the possibility of a wrong interpretation of findings, especially by beginners or when the recommended procedure is not strictly observed. In our study the device achieved the sensitivity of 31.3 % for the determination of the fertile period and the specificity of 81.8 %for the infertile period (for the days between the 7th and the25th day of menstrual cycle). Evaluating the whole cycle (from the first to the 28th day) the test specificity for the infertile period is 90 % when read by a volunteer and 93 % when read by a trained staff member. We have observed a high correlation of the evaluation by volunteers with that done by a trained staff member. On the basis of our testing we can recommend the device as a suitable complementary aid for the natural methods of planned parenthood.
650    _2
$a fertilita $x ANALÝZA $7 D005298
650    _2
$a zdravotnické prostředky $7 D004864
650    _2
$a metody přirozeného plánování rodičovství $7 D012252
650    _2
$a chronobiologické jevy $7 D002909
650    _2
$a lidé $7 D006801
650    _2
$a ženské pohlaví $7 D005260
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Oborná, Ivana, $d 1961- $4 aut $7 xx0054606
700    1_
$a Kudela, Milan, $d 1943- $4 aut $7 jn20000710365
700    1_
$a Fingerová, Helena, $d 1940- $4 aut $7 kup19960000027451
700    1_
$a Talaš, Miloslav, $d 1927-2013 $4 aut $7 nlk20020107144
700    1_
$a Březinová, Jana. $4 aut
700    1_
$a Svobodová, M. $4 aut
700    1_
$a Kršková, M. $4 aut
773    0_
$w MED00011017 $t Gynekolog $g Roč. 8, č. 5 (1999), s. 237-240 $x 1210-1133
910    __
$a ABA008 $b B 1791 $c 312a $y 0 $z 0
990    __
$a 20000413 $b ABA008
991    __
$a 20170314124018 $b ABA008
BAS    __
$a 3
BMC    __
$a 1999 $b Roč. 8 $c č. 5 $d s. 237-240 $i 1210-1133 $m Gynekolog $x MED00011017
LZP    __
$b přidání abstraktu

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...