Value of Doppler sonography in revealing transjugular intrahepatic portosystemic shunt malfunction: a 5-year experience in 216 patients
Language English Country United States Media print
Document type Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Time Factors MeSH
- Child MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Postoperative Complications diagnostic imaging MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Portasystemic Shunt, Transjugular Intrahepatic adverse effects MeSH
- Ultrasonography, Doppler * MeSH
- Check Tag
- Child MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Clinical Trial MeSH
- Research Support, Non-U.S. Gov't MeSH
OBJECTIVE: The purpose of the study was to evaluate the long-term clinical efficacy of Doppler sonography in revealing failure of transjugular intrahepatic portosystemic shunts (TIPS). SUBJECTS AND METHODS: During a 5-year period, 1192 Doppler examinations were performed in 216 patients with TIPS. No regular follow-up shunt venography was performed. Doppler examinations were retrospectively compared with the results of shunt revisions. Sonograms with negative findings were compared with the patients' clinical status so that the number of false-negative sonographic findings leading to an episode of shunt failure (recurrence of gastrointestinal bleeding or ascites) could be ascertained. Sonographic parameters assessed included diameter, velocity, flow volume, and congestion index of the portal vein; and shunt velocities. RESULTS: Doppler sonography revealed shunt occlusion in 25 of 26 angiographically proven cases (sensitivity, 96%). The combination of velocity criteria (peak intrashunt velocity > or =250 cm/sec, maximum velocity in the portal third of the shunt < or =50 cm/sec, or maximum portal vein velocity less than or equal to two thirds of the baseline value) revealed shunt stenosis in 103 of 110 cases (sensitivity, 94%). Doppler sonography missed a significant shunt stenosis that led to an episode of gastrointestinal bleeding or ascites recurrence in only seven cases. The congestion index of the portal vein showed significant differences between patent and malfunctioning shunts (p < 0.001). CONCLUSION: Doppler sonography is an effective primary imaging method for long-term follow-up of patients with TIPS.
References provided by Crossref.org
CIRSE Standards of Practice on Transjugular Intrahepatic Portosystemic Shunts
Quality improvement guidelines for Transjugular Intrahepatic Portosystemic Shunt (TIPS)