Profylaktické zavedení kontrapulzace u pacientů s tĕzkou dysfunkcí myokardu
[Prophylactic use of counterpulsation in patients with severe myocardial dysfunction]
Language Czech Country Czech Republic Media print
Document type English Abstract, Journal Article
PubMed
11387773
- MeSH
- Ventricular Dysfunction, Left complications therapy MeSH
- Intra-Aortic Balloon Pumping * MeSH
- Infant MeSH
- Coronary Artery Bypass MeSH
- Coronary Disease complications surgery MeSH
- Humans MeSH
- Mitral Valve surgery MeSH
- Preoperative Care * MeSH
- Prospective Studies MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Check Tag
- Infant MeSH
- Humans MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Publication type
- English Abstract MeSH
- Journal Article MeSH
During the period between 2/2000 and 11/2000 21 patients with severe ventricular dysfunction were investigated (EF less than 30%) where in a planned manner intraaortic balloon counterpulsation was introduced before cardiac surgery. The low mortality (5%), zero incidence of complications caused by the method and the improvement of the contractility of the heart muscle, evaluated from a rise of the ejection fraction (EF) make so-called prophylactic use of contrapulsation possible as a method of first choice in severe myocardial dysfunction.