Catalytic activity of iron hexacyanoosmate(II) towards hydrogen peroxide and nicotinamide adenine dinucleotide and its use in amperometric biosensors
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
PubMed
17870292
DOI
10.1016/j.aca.2007.07.053
PII: S0003-2670(07)01261-5
Knihovny.cz E-zdroje
- MeSH
- alkoholdehydrogenasa analýza MeSH
- alkoholické nápoje analýza MeSH
- analýza potravin metody MeSH
- biosenzitivní techniky metody MeSH
- elektrochemie metody MeSH
- enzymy imobilizované MeSH
- ethanol analýza MeSH
- ferrokyanidy chemie MeSH
- glukosa analýza MeSH
- glukosaoxidasa analýza MeSH
- katalýza MeSH
- NAD chemie MeSH
- oxid osmičelý chemie MeSH
- peroxid vodíku chemie MeSH
- sloučeniny ruthenia chemie MeSH
- železité sloučeniny chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Názvy látek
- alkoholdehydrogenasa MeSH
- enzymy imobilizované MeSH
- ethanol MeSH
- ferric ferrocyanide MeSH Prohlížeč
- ferrokyanidy MeSH
- glukosa MeSH
- glukosaoxidasa MeSH
- iron hexacyanoosmate MeSH Prohlížeč
- NAD MeSH
- oxid osmičelý MeSH
- peroxid vodíku MeSH
- sloučeniny ruthenia MeSH
- železité sloučeniny MeSH
Hydrogen peroxide and nicotinamide adenine dinucleotide (NADH) may be determined amperometrically using screen-printed electrodes chemically modified with iron(III) hexacyanoosmate(II) (Osmium purple) in flow injection analysis (FIA). The determination is based on the exploitation of catalytic currents resulting from the oxidation/reduction of the modifier. The performance of the sensor was characterized and optimized by controlling several operational parameters (applied potential, pH and flow rate of the phosphate buffer). Comparison has been made with analogous complexes of ruthenium (Ruthenium purple) and iron (Prussian blue). Taking into account the sensitivity and stability of corresponding sensors, the best results were obtained with the use of Osmium purple. The sensor exhibited a linear increase of the amperometric signal with the concentration of hydrogen peroxide in the range of 0.1-100 mg L(-1) with a detection limit (evaluated as 3sigma) of 0.024 mg L(-1) with a R.S.D. 1.5% for 10 mg L(-1) H2O2 under optimized flow rate of 0.4 mL min(-1) in 0.1M phosphate buffer carrier (pH 6) and a working potential of +0.15 V versus Ag/AgCl. Afterwards, a biological recognition element--either glucose oxidase or ethanol dehydrogenase--was incorporated to achieve a sensor facilitating the determination of glucose or ethanol, respectively. The glucose sensor gave linearity between current and concentration in the range from 1 to 250 mg L(-1) with a R.S.D. 2.4% for 100 mg L(-1) glucose, detection limit 0.02 mg L(-1) (3sigma) and retained its original activity after 3 weeks when stored at 6 degrees C. Optimal parameters in the determination of ethanol were selected as: applied potential +0.45 V versus Ag/AgCl, flow rate 0.2 mL min(-1) in 0.1 M phosphate buffer carrier (pH 7). Different structural designs of the ethanol sensor were tested and linearity obtained was up to 1000 mg L(-1) with a maximum R.S.D. of 5.1%. Applications in food analysis were also examined.
Citace poskytuje Crossref.org