Hemodynamic response to thoracoscopy and thoracotomy
Language English Country Czech Republic Media print-electronic
Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
PubMed
19681665
DOI
10.33549/physiolres.931750
PII: 1750
Knihovny.cz E-resources
- MeSH
- Time Factors MeSH
- Central Venous Pressure MeSH
- Vascular Resistance MeSH
- Adult MeSH
- Hemodynamics * MeSH
- Pneumothorax, Artificial MeSH
- Middle Aged MeSH
- Humans MeSH
- Cardiac Output MeSH
- Young Adult MeSH
- Monitoring, Intraoperative MeSH
- Pulmonary Circulation * MeSH
- Pulmonary Wedge Pressure MeSH
- Patient Positioning MeSH
- Prospective Studies MeSH
- Aged MeSH
- Thoracoscopy * MeSH
- Thoracotomy * MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
Operations in the pleural cavity are connected with circulatory changes in pulmonary circulation and general changes of hemodynamics. These changes are influenced by the position of patient's body on the operation table and by the introduction of artificial pneumothorax. Thoracoscopy is an advanced surgical approach in thoracic surgery, but its hemodynamic effect is still not known. The aim of the present study was to compare the hemodynamic response to surgeries carried out by open (thoracotomy - TT) and closed (thoracoscopy - TS) surgical approach. Thirty-eight patients have been monitored throughout the operation--from the introduction of anesthesia to completing the surgery. Monitored parameters were systolic blood pressure (BPs), diastolic blood pressure (BPd), O2 saturation (SaO2), systolic blood pressure in pulmonary artery (BPPAs), diastolic blood pressure in pulmonary artery (BPPAd), wedge pressure (P(W)), central venous pressure in right atrium (CVP), cardiac output (CO) and total peripheral resistance (TPR). No significant difference has been found in hemodynamic response between TT and TS groups. Significant changes of hemodynamic parameters occurring during the whole surgical procedure were detected in both technical approaches. The most prominent changes were found after the position of patients was changed to the hip position (significantly decreased BPs, BPd, MAP, SaO2 and BPPAs) and 5 min after the pneumothorax was established (restoration of the cardiac output to the initial value and significant decrease of the TPR). It can be concluded that the thoracoscopy causes almost identical hemodynamic changes like the thoracotomy.
References provided by Crossref.org