Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water
Jazyk angličtina Země Velká Británie, Anglie Médium print-electronic
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
PubMed
24200044
DOI
10.1016/j.chemosphere.2013.09.011
PII: S0045-6535(13)01240-X
Knihovny.cz E-zdroje
- Klíčová slova
- Integrative samplers, Modeling, Polychlorinated biphenyls, Time weighted average concentration, Water monitoring,
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- dioxiny analýza MeSH
- monitorování životního prostředí přístrojové vybavení metody MeSH
- polychlorované bifenyly analýza MeSH
- polychlorované dibenzodioxiny MeSH
- teplota MeSH
- voda chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Názvy látek
- chemické látky znečišťující vodu MeSH
- dioxiny MeSH
- polychlorované bifenyly MeSH
- polychlorované dibenzodioxiny MeSH
- voda MeSH
This study aimed at evaluating and comparing five integrative samplers for the monitoring of indicator and dioxin-like polychlorinated biphenyls (PCBs) in water: semi-permeable membrane device (SPMD), silicone rubber, low-density polyethylene (LDPE) strip, Chemcatcher and a continuous-flow integrative sampler (CFIS). These samplers were spiked with performance reference compounds (PRCs) and then simultaneously exposed under constant agitation and temperature in a 200 L stainless steel tank for periods ranging from one day to three months. A constant PCB concentration of about 1 ng·L(-1) was achieved by immersing a large amount of silicone rubber sheets ("dosing sheets") spiked with the target PCBs. The uptake of PCBs in the five samplers showed overall good repeatability and their accumulation was linear with time. The samplers SPMD, silicone rubber and LDPE strip were the most promising in terms of achieving low limits of quantification. Time-weighted average (TWA) concentrations of PCBs in water were estimated from uptake of PCBs using the sampling rates calculated from the release of PRCs. Except for Chemcatcher, a good agreement was found between the different samplers and TWA concentrations ranged between 0.4 and 2.8 times the nominal water concentration. Finally, the influence of calculation methods (sampler-water partition coefficients, selected PRCs, models) on final TWA concentrations was studied.
BRGM Monitoring and Analysis Division 3 Avenue Claude Guillemin 45060 Orléans France
Ifremer RBE BE LBCO rue de l'Ile d'Yeu 44311 Nantes Cedex 3 France
Irstea U R MALY 5 rue de la Doua CS70077 69626 Villeurbanne Cedex France
LABAQUA c Dracma 16 18 Poligono Industrial Las Atalayas 03114 Alicante Spain
LUNAM University ONIRIS LABERCA Atlanpôle La Chantrerie BP 50707 Nantes 44307 France
Suez Environnement CIRSEE 38 rue du Président Wilson 78230 Le Peck France
Citace poskytuje Crossref.org