Safety of hydroimplantation: a foldable intraocular lens implantation without the use of an ophthalmic viscosurgical device
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu srovnávací studie, časopisecké články, randomizované kontrolované studie
PubMed
24846622
DOI
10.5301/ejo.5000491
PII: ADCCD115-9105-4E43-836B-26E9215E2754
Knihovny.cz E-zdroje
- MeSH
- dvojitá slepá metoda MeSH
- fakoemulzifikace metody MeSH
- implantace nitrooční čočky metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- nitrooční čočky * MeSH
- nitrooční tlak fyziologie MeSH
- peroperační komplikace MeSH
- pooperační komplikace MeSH
- prospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tonometrie oční MeSH
- úbytek endoteliálních buněk rohovky patologie MeSH
- viskosuplementace metody MeSH
- viskosuplementy aplikace a dávkování MeSH
- zraková ostrost fyziologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
- Názvy látek
- viskosuplementy MeSH
PURPOSE: To compare the safety of a single-piece, foldable intraocular lens (IOL) hydroimplantation with that of a standard implantation using an ophthalmic viscosurgical device (OVD). METHODS: One hundred consecutive patients with bilateral age-related cataract surgery were enrolled into a prospective double-blind study. Each patient's first eye was randomly assigned to a standard implantation technique with an OVD or the hydroimplantation technique, while the fellow eye received the opposite technique. The main outcomes measured were endothelial cell loss, postoperative changes of intraocular pressure (IOP), and the frequency of complications. RESULTS: The reduction of endothelial cell density 1 month and 6 months after the surgery was 9.76% ± 13.5%, 10.7% ± 12.6%, respectively, in group A (OVD) and 9.07% ± 12.7%, 9.13% ± 13.7%, respectively, in group B (hydroimplantation). The differences were not statistically significant. The mean IOP 2 hours after surgery was 10.19 ± 6.78 mm Hg in group A and 9.92 ± 7.01 mm Hg in group B. Twenty-four hours and 1 month after surgery, the mean IOP was 14.52 ± 5.59 mm Hg and 13.21 ± 3.5 mm Hg, respectively, in group A, and 15.45 ± 5.77 mm Hg and 13.1 ± 3.44 mm Hg, respectively, in group B. The differences between groups A and B were not statistically significant. CONCLUSIONS: The hydroimplantation technique is a safe technique for single-piece foldable IOL implantation. There was no increase in intraoperative and postoperative complications compared with the standard implantation technique using an OVD.
Citace poskytuje Crossref.org