• This record comes from PubMed

Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration

. 2020 Mar 15 ; 17 (6) : . [epub] 20200315

Language English Country Switzerland Media electronic

Document type Journal Article, Research Support, Non-U.S. Gov't

The National Institute for Nuclear, Biological, and Chemical Protection, under the European project 16ENV10 MetroRADON (the European metrology program for innovation and research, EMPIR), has developed unique equipment for the testing of measuring devices at low-level radon activity concentrations. The equipment consists particularly of an airtight low-level radon chamber (LLRCH) with an inner volume of 324 liters; a Rn-222 type RF 5 flow-through source with a Ra-226 activity of 4.955 kBq developed by Czech Metrological Institute within the above-mentioned project; and a pressure vessel as a radon-free air source. The mass flow controller of the Bronkhorst EL-Flow type is a part of the apparatus and ensures the requested airflow through the radon source-partialized if necessary-through the chamber. The homogeneity of the atmosphere in the chamber is ensured by means of a continuously regulated fan (airflows in the range of 0.1-3.5 m·s-1 can be established). Another important chamber component is the measuring device of climatic conditions, since temperature, air pressure, and relative humidity must be determined. The construction of the equipment allows the time-stable radon activity concentration to be maintained at a precise level for several days. Radon concentration values can be arbitrarily and continuously set in the range from 100 Bq·m-3 to 300 Bq·m-3.

See more in PubMed

Burian I., Otahal P., Vosahlik J., Pilecka E. Fialova (née Pilecka): Czech Primary Radon Measurement Equipment. Radiat. Prot. Dosim. 2011:333–336. doi: 10.1093/rpd/ncr041. PubMed DOI

World Health Organisation, Fact Sheets, 30 June 2016. [(accessed on 6 January 2020)]; Available online: https://www.who.int/news-room/fact-sheets/detail/radon-and-health.

Paquet F., Bailey M.R., Leggett R.W., Lipsztein J., Marsh J., Fell T.P., Blanchardon E. ICRP Publication 137: Occupational Intakes of Radionuclides: Part 3. Ann. ICRP. 2017;46:1–486. doi: 10.1177/0146645317734963. PubMed DOI

Arvela H., Marsh J.W., Mclaughlin J., Tokonami S., Röttger A. ICRU Report No 88; Measurement and Reporting of Radon Exposures Technical; Journal of the ICRU Vol 12 No 2 (2012) Report 88. [(accessed on 14 March 2020)]; Available online: https://www.researchgate.net/publication/301796426_ICRU_Report_88_Measurement_and_Reporting_of_Radon_Exposures.

Council Directive 2013/59/Euratom of 5 December 2013. [(accessed on 7 January 2020)]; Available online: https://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2014:013:0001:0073:EN:PDF.

Mazanova M., Dryak P., Havelka M. Havelka: Emission probability measurement of γ− and X-rays in Ra-226 and Pb-210 decay. Appl. Radiat. Isot. 2018;134:429–432. doi: 10.1016/j.apradiso.2017.10.023. PubMed DOI

Azimi-Garakani D. A comparison of different radon chambers. Nucl. Instrum. Methods Phys. Res. 1992;B71:99–102. doi: 10.1016/0168-583X(92)95347-T. DOI

European Accreditation EA-4/02 M: 2013, Evaluation of the Uncertainty of Measurement in Calibration, September 2013. [(accessed on 6 January 2020)]; Available online: https://european-accreditation.org/wp-content/uploads/2018/10/ea-4-02-m-rev01-september-2013.pdf.

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...