Renewable sorbent dispersive solid phase extraction automated by Lab-In-Syringe using magnetite-functionalized hydrophilic-lipophilic balanced sorbent coupled online to HPLC for determination of surface water contaminants
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu časopisecké články
PubMed
35595360
DOI
10.1016/j.aca.2022.339874
PII: S0003-2670(22)00445-7
Knihovny.cz E-zdroje
- Klíčová slova
- Dispersive solid phase extraction, Environmental contaminants, High-performance liquid chromatography, Lab-in-syringe automation technique, Magnetic-functionalized sorbents,
- MeSH
- extrakce na pevné fázi MeSH
- injekční stříkačky MeSH
- oxid železnato-železitý * MeSH
- voda * chemie MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- oxid železnato-železitý * MeSH
- voda * MeSH
An automated methodology for magnetic dispersive solid phase microextraction integrating bead injection approach for renewable sorbent introduction is presented for the first time and was successfully applied to the enrichment of water contaminants. For this purpose, a simple procedure was developed for the functionalization of commercial SupelTM-Select HLB (Hydrophilic modified styrene polymer) sorbent beads that allowed embedding magnetite nanoparticles (Fe3O4). The sorbent was then used in a dispersive solid phase extraction procedure that was carried out entirely inside the void of an automatic syringe pump following the flow-batch concept of Lab-In-Syringe including automated renewal of the sorbent for each analysis. Mixing processes, sorbent dispersion, and sorbent recovery were enabled by using a strong magnetic stirring bar, fabricated from a 3D printed polypropylene casing and neodymium magnets, inside the syringe. The final extract was submitted to online coupled liquid chromatography with spectrometric detection. System and methodology were applied to determine mebendazole, bisphenol A, benzyl 4-hydroxybenzoate, diclofenac, and triclosan selected as models from different groups of environmental contaminants of current concern. Experimental parameters including extraction and elution times, composition and volume of eluent, and bead recollection were optimized. Required system elements were produced by 3D printing. Enlarging the sample volume by repeated extraction to enhance the sensitivity of the method was studied. Using double extraction from 3.5 mL, limits of detection ranged from 1.2 μg L-1 to 6.5 μg L-1 with an RSD (n = 6) value less than 7% for all the analytes at 25 μg L-1 level. The method was linear in the range of 5-200 μg L-1 and was successfully implemented for the analysis of surface waters with analyte recoveries ranging from 78.4% to 105.6%.
Citace poskytuje Crossref.org