Statistical Study on Human Temperature Measurement by Infrared Thermography
Jazyk angličtina Země Švýcarsko Médium electronic
Typ dokumentu časopisecké články
Grantová podpora
VI04000029
Ministry of the Interior
CZ.02.1.01/0.0/0.0/18_069/0010018
Ministry of Education Youth and Sports
PubMed
36366093
PubMed Central
PMC9654967
DOI
10.3390/s22218395
PII: s22218395
Knihovny.cz E-zdroje
- Klíčová slova
- body temperature, emerging diseases, fever screening, human temperature, infection control, infectious diseases, infrared thermography, medical thermography, thermal imaging, thermographic measurement,
- MeSH
- horečka diagnóza MeSH
- infračervené záření * MeSH
- lidé MeSH
- tělesná teplota MeSH
- teplota MeSH
- termografie * metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Increased temperature in humans is the symptom of many infectious diseases and it is thus an important diagnostic tool. Infrared temperature measurement methods have been developed and applied over long periods due to their advantage of non-contact and fast measurements. This study deals with a statistical evaluation of the possibilities and limitations of infrared/thermographic human temperature measurement. A short review of the use of infrared temperature measurement in medical applications is provided. Experiments and statistics-based evaluation to confirm the expected accuracy and limits of thermography-based human temperature measurement are introduced. The results presented in this study show that the standard deviation of the thermographic measurement of the eyes maximum temperature was 0.4-0.9 °C and the mean values differences from the armpit measurement were up to 0.5 °C, based on the used IR camera, even though near ideal measurement conditions and permanent blackbody correction were used. It was also shown that a certain number of outliers must be assumed in such measurements. Extended analyses including simulations of true negative/false positive, sensitivity/specificity and receiver operating characteristics (ROC) curves are presented. The statistical evaluation as well as the extended analyses show that maximum eyes temperature is more relevant than a forehead temperature examination.
Zobrazit více v PubMed
Lahiri B., Bagavathiappan S., Jayakumar T., Philip J. Medical applications of infrared thermography: A review. Infrared Phys. Technol. 2012;55:221–235. doi: 10.1016/j.infrared.2012.03.007. PubMed DOI PMC
Sund-Levander M., Forsberg C., Wahren L.K. Normal oral, rectal, tympanic and axillary body temperature in adult men and women: A systematic literature review. Scand. J. Caring Sci. 2002;16:122–128. doi: 10.1046/j.1471-6712.2002.00069.x. PubMed DOI
Hymczak H., Gołąb A., Mendrala K., Plicner D., Darocha T., Podsiadło P., Hudziak D., Gocoł R., Kosiński S. Core Temperature Measurement—Principles of Correct Measurement, Problems, and Complications. Int. J. Environ. Res. Public Health. 2021;18:10606. doi: 10.3390/ijerph182010606. PubMed DOI PMC
Geneva I.I., Cuzzo B., Fazili T., Javaid W. Normal Body Temperature: A Systematic Review. Open Forum Infect. Dis. 2019;6:ofz032. doi: 10.1093/ofid/ofz032. PubMed DOI PMC
Moran D.S., Mendal L. Core Temperature Measurement. Sports Med. 2002;32:879–885. doi: 10.2165/00007256-200232140-00001. PubMed DOI
Werner J. Measurement of Temperatures of the Human Body. Compr. Biomed. Phys. 2014:107–126. doi: 10.1016/b978-0-444-53632-7.00515-3. DOI
Ergonomie—Hodnocení Tepelné Zátěže Podle Fyziologických Měření (Ergonomics—Evaluation of Thermal Strain by Physiological Measurements) Czech Standards Institute; Prague, Czech Republic: 2004.
Svantner M., Lang V., Skala J., Kohlschutter T., Honner M., Muzika L., Kosova E. Possibilities and limits of human temperature measurement by thermographic methods; Proceedings of the 2022 IEEE International Workshop on Metrology for Living Environment (MetroLivEn); Cosenza, Italy. 25–27 May 2022; Cosenza, Italy: University of Calabria; 2022. pp. 29–33. DOI
Ring E.F.J. The technique of infrared imaging in medicine. Infrared Imaging Casebook Clin. Med. 2014 doi: 10.1088/978-0-7503-1143-4ch1. DOI
Medical Electrical Equipment—Part 2-59: Particular Requirements for Basic Safety and Essential Performance of Screening Thermographs for Human Febrile Temperature Screening. Czech Standardization Agency; Prague, Czech Republic: 2019.
Kim N.W., Zhang H.Y., Yoo J.-H., Park Y.S., Song H.J., Yang K.H. The correlation between tympanic membrane temperature and specific region of face temperature. Quant. Infrared Thermogr. J. 2019;16:1497877. doi: 10.1080/17686733.2018.1497877. DOI
Piccinini F., Martinelli G., Carbonaro A. Reliability of Body Temperature Measurements Obtained with Contactless Infrared Point Thermometers Commonly Used during the COVID-19 Pandemic. Sensors. 2021;21:3794. doi: 10.3390/s21113794. PubMed DOI PMC
Chiang M.-F., Lin P.-W., Lin L.-F., Chiou H.Y., Chien C.-W., Chu S.-F., Chiu W.-T. Mass Screening of Suspected Febrile Patients with Remote-sensing Infrared Thermography: Alarm Temperature and Optimal Distance. J. Formos. Med. Assoc. 2008;107:937–944. doi: 10.1016/S0929-6646(09)60017-6. PubMed DOI PMC
Vardasca R., Marques A.R., Diz J., Seixas A., Mendes J., Ring E.F.J. The influence of angles and distance on assessing in-ner-canthi of the eye skin temperature. Thermol. Int. 2017;27:130–135.
Fernández-Cuevas I., Marins J.C.B., Lastras J.A., Carmona P.M.G., Cano S.P., García-Concepción M.Á., Sillero-Quintana M. Classification of factors influencing the use of infrared thermography in humans: A review. Infrared Phys. Technol. 2015;71:28–55. doi: 10.1016/j.infrared.2015.02.007. DOI
Ng E.Y., Kawb G., Chang W. Analysis of IR thermal imager for mass blind fever screening. Microvasc. Res. 2004;68:104–109. doi: 10.1016/j.mvr.2004.05.003. PubMed DOI
Chiu W.T., Lin P.W., Chiou H., Lee W., Lee C., Yang Y., Lee H., Hsieh M., Hu C.J., Ho Y., et al. Infrared Thermography to Mass-Screen Suspected Sars Patients with Fever. Asia Pac. J. Public Health. 2005;17:26–28. doi: 10.1177/101053950501700107. PubMed DOI
Bitar D., Goubar A., Desenclos J.C. International travels and fever screening during epidemics: A literature review on the effectiveness and potential use of non-contact infrared thermometers. Eurosurveillance. 2009;14:19115. doi: 10.2807/ese.14.06.19115-en. PubMed DOI
Nguyen A.V., Cohen N.J., Lipman H., Brown C.M., Molinari N.-A., Jackson W.L., Kirking H., Szymanowski P., Wilson T.W., Salhi B., et al. Comparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening. Emerg. Infect. Dis. 2010;16:1710–1717. doi: 10.3201/eid1611.100703. PubMed DOI PMC
Nishiura H., Kamiya K. Fever screening during the influenza (H1N1-2009) pandemic at Narita International Airport, Japan. BMC Infect. Dis. 2011;11:111. doi: 10.1186/1471-2334-11-111. PubMed DOI PMC
Cosford P. Airport screening for Ebola: Advantages of airport screening for Ebola. BMJ. 2014;349:g6585. doi: 10.1136/bmj.g6585. PubMed DOI
Gulland A. Experts question usefulness of screening travellers to UK for Ebola. BMJ. 2014;349:g6199. doi: 10.1136/bmj.g6199. PubMed DOI
Taylor W., Abbasi Q., Dashtipour K., Ansari S., Shah S., Khalid A., Imran M. A Review of the State of the Art in Non-Contact Sensing for COVID-19. Sensors. 2020;20:5665. doi: 10.3390/s20195665. PubMed DOI PMC
Sumriddetchkajorn S., Chaitavon K. Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach. Infrared Phys. Technol. 2009;52:119–123. doi: 10.1016/j.infrared.2009.04.002. DOI
Pitman R.J., Cooper B.S., Trotter C.L., Gay N.J., Edmunds W.J. Entry screening for severe acute respiratory syndrome (SARS) or influenza: Policy evaluation. BMJ. 2005;331:1242–1243. doi: 10.1136/bmj.38573.696100.3A. PubMed DOI PMC
Matsui T., Hakozaki Y., Suzuki S., Usui T., Kato T., Hasegawa K., Sugiyama Y., Sugamata M., Abe S. A novel screening method for influenza patients using a newly developed non-contact screening system. J. Infect. 2010;60:271–277. doi: 10.1016/j.jinf.2010.01.005. PubMed DOI PMC
Sun G., Matsui T., Hakozaki Y., Abe S. An infectious disease/fever screening radar system which stratifies higher-risk patients within ten seconds using a neural network and the fuzzy grouping method. J. Infect. 2014;70:230–236. doi: 10.1016/j.jinf.2014.12.007. PubMed DOI PMC
Sun G., Akanuma M., Matsui T. Clinical evaluation of the newly developed infectious disease/fever screening radar system using the neural network and fuzzy grouping method for travellers with suspected infectious diseases at Narita International Airport Clinic. J. Infect. 2016;72:121–123. doi: 10.1016/j.jinf.2015.09.017. PubMed DOI
Švantner M., Lang V., Kohlschutter T., Skála J., Honner M., Muzika L., Kosová E. Study on Human Temperature Measurement by Infrared Thermography. Eng. Proc. 2021;8:4. doi: 10.3390/engproc2021008004. PubMed DOI PMC
Zhou Y., Ghassemi P., Chen M., McBride D., Casamento J.P., Pfefer T.J., Wang Q. Clinical evaluation of fever-screening thermography: Impact of consensus guidelines and facial measurement location. J. Biomed. Opt. 2020;25:097002. doi: 10.1117/1.jbo.25.9.097002. PubMed DOI PMC
Wang Q., Zhou Y., Ghassemi P., McBride D., Casamento J.P., Pfefer T.J. Infrared Thermography for Measuring Elevated Body Temperature: Clinical Accuracy, Calibration, and Evaluation. Sensors. 2021;22:215. doi: 10.3390/s22010215. PubMed DOI PMC
Foster J., Lloyd A.B., Havenith G. Non-contact infrared assessment of human body temperature: The journal Temperature toolbox. Temperature. 2021;8:306–319. doi: 10.1080/23328940.2021.1899546. PubMed DOI PMC
E Shapiro D. The interpretation of diagnostic tests. Stat. Methods Med. Res. 1999;8:113–134. doi: 10.1177/096228029900800203. PubMed DOI
Chen H.-Y., Chen A., Chen C. Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites. Sensors. 2020;20:2885. doi: 10.3390/s20102885. PubMed DOI PMC
Wan Q., Brede B., Smigaj M., Kooistra L. Factors Influencing Temperature Measurements from Miniaturized Thermal Infrared (TIR) Cameras: A Laboratory-Based Approach. Sensors. 2021;21:8466. doi: 10.3390/s21248466. PubMed DOI PMC
Measurement and Processing of Thermographic Data of Passing Persons for Epidemiological Purposes
Statistical Study on Human Temperature Measurement by Infrared Thermography