Statistical Study on Human Temperature Measurement by Infrared Thermography

. 2022 Nov 01 ; 22 (21) : . [epub] 20221101

Jazyk angličtina Země Švýcarsko Médium electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid36366093

Grantová podpora
VI04000029 Ministry of the Interior
CZ.02.1.01/0.0/0.0/18_069/0010018 Ministry of Education Youth and Sports

Increased temperature in humans is the symptom of many infectious diseases and it is thus an important diagnostic tool. Infrared temperature measurement methods have been developed and applied over long periods due to their advantage of non-contact and fast measurements. This study deals with a statistical evaluation of the possibilities and limitations of infrared/thermographic human temperature measurement. A short review of the use of infrared temperature measurement in medical applications is provided. Experiments and statistics-based evaluation to confirm the expected accuracy and limits of thermography-based human temperature measurement are introduced. The results presented in this study show that the standard deviation of the thermographic measurement of the eyes maximum temperature was 0.4-0.9 °C and the mean values differences from the armpit measurement were up to 0.5 °C, based on the used IR camera, even though near ideal measurement conditions and permanent blackbody correction were used. It was also shown that a certain number of outliers must be assumed in such measurements. Extended analyses including simulations of true negative/false positive, sensitivity/specificity and receiver operating characteristics (ROC) curves are presented. The statistical evaluation as well as the extended analyses show that maximum eyes temperature is more relevant than a forehead temperature examination.

Zobrazit více v PubMed

Lahiri B., Bagavathiappan S., Jayakumar T., Philip J. Medical applications of infrared thermography: A review. Infrared Phys. Technol. 2012;55:221–235. doi: 10.1016/j.infrared.2012.03.007. PubMed DOI PMC

Sund-Levander M., Forsberg C., Wahren L.K. Normal oral, rectal, tympanic and axillary body temperature in adult men and women: A systematic literature review. Scand. J. Caring Sci. 2002;16:122–128. doi: 10.1046/j.1471-6712.2002.00069.x. PubMed DOI

Hymczak H., Gołąb A., Mendrala K., Plicner D., Darocha T., Podsiadło P., Hudziak D., Gocoł R., Kosiński S. Core Temperature Measurement—Principles of Correct Measurement, Problems, and Complications. Int. J. Environ. Res. Public Health. 2021;18:10606. doi: 10.3390/ijerph182010606. PubMed DOI PMC

Geneva I.I., Cuzzo B., Fazili T., Javaid W. Normal Body Temperature: A Systematic Review. Open Forum Infect. Dis. 2019;6:ofz032. doi: 10.1093/ofid/ofz032. PubMed DOI PMC

Moran D.S., Mendal L. Core Temperature Measurement. Sports Med. 2002;32:879–885. doi: 10.2165/00007256-200232140-00001. PubMed DOI

Werner J. Measurement of Temperatures of the Human Body. Compr. Biomed. Phys. 2014:107–126. doi: 10.1016/b978-0-444-53632-7.00515-3. DOI

Ergonomie—Hodnocení Tepelné Zátěže Podle Fyziologických Měření (Ergonomics—Evaluation of Thermal Strain by Physiological Measurements) Czech Standards Institute; Prague, Czech Republic: 2004.

Svantner M., Lang V., Skala J., Kohlschutter T., Honner M., Muzika L., Kosova E. Possibilities and limits of human temperature measurement by thermographic methods; Proceedings of the 2022 IEEE International Workshop on Metrology for Living Environment (MetroLivEn); Cosenza, Italy. 25–27 May 2022; Cosenza, Italy: University of Calabria; 2022. pp. 29–33. DOI

Ring E.F.J. The technique of infrared imaging in medicine. Infrared Imaging Casebook Clin. Med. 2014 doi: 10.1088/978-0-7503-1143-4ch1. DOI

Medical Electrical Equipment—Part 2-59: Particular Requirements for Basic Safety and Essential Performance of Screening Thermographs for Human Febrile Temperature Screening. Czech Standardization Agency; Prague, Czech Republic: 2019.

Kim N.W., Zhang H.Y., Yoo J.-H., Park Y.S., Song H.J., Yang K.H. The correlation between tympanic membrane temperature and specific region of face temperature. Quant. Infrared Thermogr. J. 2019;16:1497877. doi: 10.1080/17686733.2018.1497877. DOI

Piccinini F., Martinelli G., Carbonaro A. Reliability of Body Temperature Measurements Obtained with Contactless Infrared Point Thermometers Commonly Used during the COVID-19 Pandemic. Sensors. 2021;21:3794. doi: 10.3390/s21113794. PubMed DOI PMC

Chiang M.-F., Lin P.-W., Lin L.-F., Chiou H.Y., Chien C.-W., Chu S.-F., Chiu W.-T. Mass Screening of Suspected Febrile Patients with Remote-sensing Infrared Thermography: Alarm Temperature and Optimal Distance. J. Formos. Med. Assoc. 2008;107:937–944. doi: 10.1016/S0929-6646(09)60017-6. PubMed DOI PMC

Vardasca R., Marques A.R., Diz J., Seixas A., Mendes J., Ring E.F.J. The influence of angles and distance on assessing in-ner-canthi of the eye skin temperature. Thermol. Int. 2017;27:130–135.

Fernández-Cuevas I., Marins J.C.B., Lastras J.A., Carmona P.M.G., Cano S.P., García-Concepción M.Á., Sillero-Quintana M. Classification of factors influencing the use of infrared thermography in humans: A review. Infrared Phys. Technol. 2015;71:28–55. doi: 10.1016/j.infrared.2015.02.007. DOI

Ng E.Y., Kawb G., Chang W. Analysis of IR thermal imager for mass blind fever screening. Microvasc. Res. 2004;68:104–109. doi: 10.1016/j.mvr.2004.05.003. PubMed DOI

Chiu W.T., Lin P.W., Chiou H., Lee W., Lee C., Yang Y., Lee H., Hsieh M., Hu C.J., Ho Y., et al. Infrared Thermography to Mass-Screen Suspected Sars Patients with Fever. Asia Pac. J. Public Health. 2005;17:26–28. doi: 10.1177/101053950501700107. PubMed DOI

Bitar D., Goubar A., Desenclos J.C. International travels and fever screening during epidemics: A literature review on the effectiveness and potential use of non-contact infrared thermometers. Eurosurveillance. 2009;14:19115. doi: 10.2807/ese.14.06.19115-en. PubMed DOI

Nguyen A.V., Cohen N.J., Lipman H., Brown C.M., Molinari N.-A., Jackson W.L., Kirking H., Szymanowski P., Wilson T.W., Salhi B., et al. Comparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening. Emerg. Infect. Dis. 2010;16:1710–1717. doi: 10.3201/eid1611.100703. PubMed DOI PMC

Nishiura H., Kamiya K. Fever screening during the influenza (H1N1-2009) pandemic at Narita International Airport, Japan. BMC Infect. Dis. 2011;11:111. doi: 10.1186/1471-2334-11-111. PubMed DOI PMC

Cosford P. Airport screening for Ebola: Advantages of airport screening for Ebola. BMJ. 2014;349:g6585. doi: 10.1136/bmj.g6585. PubMed DOI

Gulland A. Experts question usefulness of screening travellers to UK for Ebola. BMJ. 2014;349:g6199. doi: 10.1136/bmj.g6199. PubMed DOI

Taylor W., Abbasi Q., Dashtipour K., Ansari S., Shah S., Khalid A., Imran M. A Review of the State of the Art in Non-Contact Sensing for COVID-19. Sensors. 2020;20:5665. doi: 10.3390/s20195665. PubMed DOI PMC

Sumriddetchkajorn S., Chaitavon K. Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach. Infrared Phys. Technol. 2009;52:119–123. doi: 10.1016/j.infrared.2009.04.002. DOI

Pitman R.J., Cooper B.S., Trotter C.L., Gay N.J., Edmunds W.J. Entry screening for severe acute respiratory syndrome (SARS) or influenza: Policy evaluation. BMJ. 2005;331:1242–1243. doi: 10.1136/bmj.38573.696100.3A. PubMed DOI PMC

Matsui T., Hakozaki Y., Suzuki S., Usui T., Kato T., Hasegawa K., Sugiyama Y., Sugamata M., Abe S. A novel screening method for influenza patients using a newly developed non-contact screening system. J. Infect. 2010;60:271–277. doi: 10.1016/j.jinf.2010.01.005. PubMed DOI PMC

Sun G., Matsui T., Hakozaki Y., Abe S. An infectious disease/fever screening radar system which stratifies higher-risk patients within ten seconds using a neural network and the fuzzy grouping method. J. Infect. 2014;70:230–236. doi: 10.1016/j.jinf.2014.12.007. PubMed DOI PMC

Sun G., Akanuma M., Matsui T. Clinical evaluation of the newly developed infectious disease/fever screening radar system using the neural network and fuzzy grouping method for travellers with suspected infectious diseases at Narita International Airport Clinic. J. Infect. 2016;72:121–123. doi: 10.1016/j.jinf.2015.09.017. PubMed DOI

Švantner M., Lang V., Kohlschutter T., Skála J., Honner M., Muzika L., Kosová E. Study on Human Temperature Measurement by Infrared Thermography. Eng. Proc. 2021;8:4. doi: 10.3390/engproc2021008004. PubMed DOI PMC

Zhou Y., Ghassemi P., Chen M., McBride D., Casamento J.P., Pfefer T.J., Wang Q. Clinical evaluation of fever-screening thermography: Impact of consensus guidelines and facial measurement location. J. Biomed. Opt. 2020;25:097002. doi: 10.1117/1.jbo.25.9.097002. PubMed DOI PMC

Wang Q., Zhou Y., Ghassemi P., McBride D., Casamento J.P., Pfefer T.J. Infrared Thermography for Measuring Elevated Body Temperature: Clinical Accuracy, Calibration, and Evaluation. Sensors. 2021;22:215. doi: 10.3390/s22010215. PubMed DOI PMC

Foster J., Lloyd A.B., Havenith G. Non-contact infrared assessment of human body temperature: The journal Temperature toolbox. Temperature. 2021;8:306–319. doi: 10.1080/23328940.2021.1899546. PubMed DOI PMC

E Shapiro D. The interpretation of diagnostic tests. Stat. Methods Med. Res. 1999;8:113–134. doi: 10.1177/096228029900800203. PubMed DOI

Chen H.-Y., Chen A., Chen C. Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites. Sensors. 2020;20:2885. doi: 10.3390/s20102885. PubMed DOI PMC

Wan Q., Brede B., Smigaj M., Kooistra L. Factors Influencing Temperature Measurements from Miniaturized Thermal Infrared (TIR) Cameras: A Laboratory-Based Approach. Sensors. 2021;21:8466. doi: 10.3390/s21248466. PubMed DOI PMC

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...