Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis
Jazyk angličtina Země Velká Británie, Anglie Médium print-electronic
Typ dokumentu časopisecké články
PubMed
37364452
DOI
10.1016/j.jpba.2023.115542
PII: S0731-7085(23)00311-4
Knihovny.cz E-zdroje
- Klíčová slova
- Antibodies, Liquid chromatography, Mass spectrometry, Multiple sclerosis, Natalizumab, Serum,
- MeSH
- chromatografie kapalinová metody MeSH
- humanizované monoklonální protilátky terapeutické užití MeSH
- lidé MeSH
- natalizumab terapeutické užití MeSH
- peptidy terapeutické užití MeSH
- roztroušená skleróza * farmakoterapie MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- humanizované monoklonální protilátky MeSH
- natalizumab MeSH
- peptidy MeSH
Natalizumab is a humanized recombinant monoclonal IgG4 antibody used in the treatment of multiple sclerosis. Commonly used methods for natalizumab and anti-natalizumab antibodies quantification are enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay, respectively. Measurement of therapeutic monoclonal antibodies can be challenging due to the resemblance to human plasma immunoglobulins. Recent developments in mass spectrometry enables to analyze vast variety of large protein molecules. The aim of this study was to develop a LC-MS/MS method for determining natalizumab in human serum and cerebrospinal fluid (CSF) and apply it to clinical settings. For successful quantification, it was necessary to find specific sequences of peptides in natalizumab. This immunoglobulin was treated with dithiothreitol and iodoacetamide, cleaved with trypsin into short specific peptides and determined on a UPLC-MS/MS system. An Acquity UPLC BEH C18 column at 55 °C and gradient elution was used for analysis. Intra- and interassay accuracies and precisions were tested at four concentration levels. Precision was determined by coefficients of variation and was in the range of 0.8-10.2 %, with accuracy in the range of 89.8-106.4 %. The concentration of natalizumab in patient samples ranged from 1.8 to 193.3 μg/mL. The method was validated according to the European Medicines Agency (EMA) guideline, met all acceptance criteria for accuracy and precision, and is suitable for clinical applications. In comparison to immunoassay, which can be elevated by cross-reaction with endogenous immunoglobulins, the results of developed LC-MS/MS method are more accurate and specific.