Chiral zwitterionic stationary phases based on Cinchona alkaloids and dipeptides: Application in chiral separation of dipeptides under reversed phase conditions
Language English Country Netherlands Media print-electronic
Document type Journal Article
PubMed
38735116
DOI
10.1016/j.chroma.2024.464966
PII: S0021-9673(24)00340-6
Knihovny.cz E-resources
- Keywords
- Chiral separation, Chiral zwitterion ion exchangers, Cinchona alkaloids, Dipeptides, Zwitterionic species,
- MeSH
- Quinine chemistry isolation & purification MeSH
- Cinchona Alkaloids * chemistry MeSH
- Chromatography, Reverse-Phase * methods MeSH
- Dipeptides * chemistry isolation & purification MeSH
- Hydrophobic and Hydrophilic Interactions * MeSH
- Stereoisomerism MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Publication type
- Journal Article MeSH
Chromatographic behavior of novel chiral stationary phases with bonded selectors based on Cinchona alkaloids modified with dipeptides was studied using dipeptides as probe molecules. Buffer-free and salt containing hydro-organic solutions were used as the mobile phases. The selectors exhibit pseudoenantiomeric behavior with respect to the L/D or LL/DD enantiomers and do not behave so with respect to the LD/DL enantiomers. The alkaloid part of the selectors is the driver of enantioselectivity, while the dipeptide substituent plays a modulating role. The quinidine-based selectors demonstrate stronger adsorption affinity and higher enantioselectivity as compared to the quinine-based selectors. The dipeptide analytes containing a glycyl fragment are weaker retained and their enantiomers are worse separated comparing to dipeptides with both units being larger amino acids. Moreover, a phenyl group in the structure of a dipeptide analyte facilitates enantioseparation. The effect of the mobile phase composition on retention depends on the hydrophobicity of an analyte. Hydrophobic dipeptides are better eluted by methanol-rich solvents, hydrophilic dipeptides are better eluted with water-rich solvents, and dipeptides with an intermediate hydrophobicity demonstrate a U-shaped or more complicated dependence of the retention factor on the percentage of methanol. Even a small buffer addition to the mobile phase decreases retention, but the ion-exchange mechanism was not confirmed. The effect of an electrolyte is rather due to the shielding of the charged groups of the selector reducing thereby electrostatic interaction between the selector and analyte. Efficiency of the novel columns is comparable to that of other brush-type chiral columns, the highest achieved number of the theoretical plates per 1 m varying between 30,000 and 40,000.
References provided by Crossref.org