Measurement of neutron spectra in spent fuel storage

. 2024 Dec ; 214 () : 111552. [epub] 20241018

Status PubMed-not-MEDLINE Jazyk angličtina Země Anglie, Velká Británie Médium print-electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid39427477
Odkazy

PubMed 39427477
DOI 10.1016/j.apradiso.2024.111552
PII: S0969-8043(24)00380-4
Knihovny.cz E-zdroje

The neutron spectrum was measured at two locations in the spent fuel storage facility of the Temelín nuclear power plant. The measurement had two primary objectives: to map the neutron -γ field by quantifying the ambient dose equivalent H∗(10) and to identify methods that could improve the quality of the adjusted neutron spectrum using a Bonner Sphere Spectrometer (BSS). Three spectrometers were used: a BSS and two proton recoil spectrometers. Hydrogen-filled proportional counters and an EJ309 scintillator were used to construct the a priori spectrum for BSS adjustment. The details of this process and its results are discussed. The a posteriori spectrum was used to calculate the ambient dose equivalent H∗(10). The resulting spectrum is highly thermalised, but the predominant contribution to H∗(10) was in the 100 keV-1.3 MeV range. The use of hydrogen-proportional counters in combination with the BSS is recommended.