Assessment of the accuracy of patient-specific drilling guides for cervical (C5-C6) and lumbar (L4-L5) vertebrae in cats

. 2025 Jan ; 70 (1) : 11-19. [epub] 20250120

Status PubMed-not-MEDLINE Jazyk angličtina Země Česko Médium electronic-ecollection

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid39990158

Ten sets of vertebral biomodels and the corresponding drilling guides were created to evaluate the implantation accuracy in the cervical (C5-C6) and lumbar (L4-L5) vertebrae of cats. Smooth pins were implanted using the guides on the right side of five randomly assigned biomodel sets and on the left side of the remaining sets, with the contralateral side undergoing freehand implantation. Subsequently, a new tomographic study was conducted to measure the implantation angles. The pre-implantation angles were compared with the post-implantation angles between the techniques and among the sets. The guide-assisted implantation exhibited a lower dispersion compared to the freehand technique, with coefficients of variation of -1.95 and 48.9 in the cervical vertebrae and 1.98 and 9.39 in the lumbar vertebrae, respectively. However, no statistical difference was observed between the pre- and post-implantation angles, nor when comparing the vertebral segments (P > 0.05). Under the study conditions, the use of the guide failed to result in more accurate implantations in the C5-C6 and L4-L5 vertebral biomodels of cats.

Zobrazit více v PubMed

Beer P, Park BH, Steffen F, Smolders DLA, Pozzi A, Knell SC. Influence of a customized three-dimensionally printed drill guide on the accuracy of pedicle screw placement in lumbosacral vertebrae: An ex vivo study. Vet Surg. 2020 Jul;49(5):977-88. PubMed

Bongers JJ, Wilkinson N, Kurihara M, Bridges JP, Baltzer W, Worth AJ. Accuracy of lumbosacral pedicle screw placement in dogs: A novel 3D printed patient-specific drill guide versus freehand technique in novice and expert surgeons. Vet Comp Orthop Traumatol. 2022 Nov;35(6):381-9. PubMed

Burleson J, DiPaola C. 3D printing in spine surgery. In: DiPaola M, Wodajo FM, editors. 3D printing in orthopaedic surgery. Philadelphia: Elsevier; 2019. p. 105-22.

Catalkaya E, Altan S, Ersoz-Kanay B, Yayla S, Saylak N. Clinical and etiological evaluation of cats with high-rise syndrome: Assessment of 72 cases (a retrospective study). MAE Vet Fak Derg. 2022;7(1):20-5.

Conroy M, O’Neill DG, Boag A, Brodbelt D. Epidemiology of road traffic accidents in cats attending emergency-care practices in the UK. J Small Anim Pract. 2019 Mar;60(3):146-52. PubMed

Espadas I, Maddox TW, Vicente F. Optimal safe implantation corridors in feline cervical vertebrae (C2–T1): CT study in 16 domestic shorthair cats. J Feline Med Surg. 2018 Dec;20(12):1149-57. PubMed PMC

Fujioka T, Nakata K, Nishida H, Sugawara T, Konno N, Maeda S, Kamishina H. A novel patient-specific drill guide template for stabilization of thoracolumbar vertebrae of dogs: Cadaveric study and clinical cases. Vet Surg. 2018 Mar;48(3):336-42. PubMed

Hamilton-Bennett SE, Oxley B, Behr S. Accuracy of a patient-specific 3D printed drill guide for placement of cervical transpedicular screws. Vet Surg. 2017 Mar;47(2):236-42. PubMed

Hsu MR, Haleem MS, Hsu W. 3D printing applications in minimally invasive spine surgery. Minim Invasive Surg. 2018;2018:1-8. PubMed PMC

Jeffery ND. Vertebral fracture and luxation in small animals. Vet Clin N Am Small Anim Pract. 2010 Sep;40(5):809-28. PubMed

Kamishina H, Sugawara T, Nakata K, Nishida H, Yada N, Fujioka T, Nagata Y, Doi A, Konno N, Uchida F, Maeda S. Clinical application of 3D printing technology to the surgical treatment of atlantoaxial subluxation in small breed dogs. PLoS One. 2019 May;14(5):1-18. PubMed PMC

Keosengthong A, Kampa N, Jitpean S, Seesupa S, Kunkitti P, Hoisang S. Incidence and classification of bone fracture in dogs and cats: A retrospective study at a veterinary teaching hospital, Khon Kaen University, Thailand (2013–2016). Vet Integr Sci. 2019;17(2):127-39.

Kim KY, Kim M, Park JH, Shin JI, Kim J, Jang YS, Lee JH. Stabilization using screws, wire, and PMMA for traumatic cervical fracture in a Maltese dog. J Vet Clin. 2014;31(6):519-22.

Martinelli N, Serrano C, Van Den Brink H, Pineau J, Prognon P, Borget I, Batti SE. Advantages and disadvantages of 3-dimensional printing in surgery: A systematic review. Surgery. 2016 Jun;159(6):1485-500. PubMed

Monteiro BF. Desenvolvimento e analise da eficacia de guia cirurgico paciente-especifico produzido por impressao 3D para aplicacao de pinos transarticulares atlantoaxiais em caes miniaturas [Development and analysis of the effectiveness of a patient-specific surgical guide by 3D printing for atlantoaxial transarticular pins implantation in miniature dogs][dissertation]. [São Paulo]: FMVZ-USP; 2018. 172 p. Portuguese.

Nanni FN, Vialle EN, Foggiattob JA, Silva KWSN, Neto HOM. Desenvolvimento de um guia paciente-especifico para fixacao de coluna cervical alta [Development of a patient-specific guide for upper cervical spine fixation]. Rev Bras Ortop. 2019;54(1):20-5. Portuguese. PubMed PMC

Orgonikova I, Brocal J, Cherubini GB, Palus V. Vertebral fractures and luxations in dogs and cats, part 1: Evaluation of diagnosis and prognosis. Comp Anim. 2021a;26(2):1-10.

Orgonikova I, Brocal J, Cherubini GB, Palus V. Vertebral fractures and luxations in dogs and cats, part 2: Treatment and surgery options. Comp Anim. 2021b;26(2):15-9.

Ozak A, Inal KS. Stabilisation in spinal trauma. J Vet Sci Surg – Special Topics. 2016;2(3):50-9.

Rocha LM. Introducao a tomografia computadorizada e ressonancia magnetica: Tomografia computadorizada [Introduction to computed tomography and magnetic ressonance imaging: Computed tomography]. In: Feliciano MAR, Canola JC, Vicente WRR, editors. Diagnostico por imagem em caes e gatos. São Paulo: Medvet; 2015. p. 34-9. Portuguese.

Saengthong AD, Akatvipat A, Boonyayatra S. Vertebral fracture and dislocation patterns, location of injuries, and 6-month clinical outcomes in cats: A retrospective study. Vet Integr Sci. 2022;20(2):405-17.

Serra F, Aste G, Citi S, Tamburro R, Simeoni F, Carloni A, Terragni R, Vignoli M. Computed tomography in polytraumatized patients: A retrospective study of 63 cases (2014–2017). Pak Vet J. 2021;41(1):7-12.

Toni C, Oxley B, Clarke S, Behr S. Accuracy of placement of pedicle screws in the lumbosacral region of dogs using 3D-printed patient-specific drill guides. Vet Comp Orthop Traumatol. 2020;34(1):53-8. PubMed

Vallefuoco R, Manassero M, Leperlier D, Scotti S, Viateau V, Moissonnier P. Surgical repair of thoraco-lumbar vertebral fracture-luxations in eight cats using screws and polymethylmethacrylate fixation. Vet Comp Orthop Traumatol. 2014;27(4):306-12. PubMed

Watine S, Cabassu JP, Catheland S, Brochier L, Ivanoff S. Computed tomography study of implantation corridors in canine vertebrae. J Small Anim Pract. 2006 Nov;47(11):651-7. PubMed

Najít záznam