BACKGROUND: Strokes after left atrial appendage closure (LAAC) prophylaxis are generally less severe than those after warfarin prophylaxis-thought to be secondary to more hemorrhagic strokes with warfarin. Hemorrhagic strokes are similarly infrequent with direct oral anticoagulant (DOAC) prophylaxis, so the primary subtype after either LAAC or DOAC prophylaxis is ischemic stroke (IS). OBJECTIVES: The purpose of this study was to compare the severity of IS using the modified Rankin Scale in atrial fibrillation patients receiving prophylaxis with DOACs vs LAAC. METHODS: A retrospective analysis was performed of consecutive patients undergoing LAAC at 8 centers who developed an IS (ISLAAC) compared with contemporaneous consecutive patients who developed IS during treatment with DOACs (ISDOAC). The primary outcome was disabling/fatal stroke (modified Rankin Scale 3-5) at discharge and 3 months later. RESULTS: Compared with ISDOAC patients (n = 322), ISLAAC patients (n = 125) were older (age 77.2 ± 13.4 years vs 73.1 ± 11.9 years; P = 0.002), with higher HAS-BLED scores (3.0 vs 2.0; P = 0.004) and more frequent prior bleeding events (54.4% vs 23.6%; P < 0.001), but similar CHA2DS2-VASc scores (5.0 vs 5.0; P = 0.28). Strokes were less frequently disabling/fatal with ISLAAC than ISDOAC at both hospital discharge (38.3% vs 70.3%; P < 0.001) and 3 months later (33.3% vs 56.2%; P < 0.001). Differences in stroke severity persisted after propensity score matching. By multivariate regression analysis, ISLAAC was independently associated with fewer disabling/fatal strokes at discharge (OR: 0.22; 95% CI: 0.13-0.39; P < 0.001) and 3 months (OR: 0.25; 95% CI: 0.12-0.50; P < 0.001), and fewer deaths at 3 months (OR: 0.28; 95% CI: 0.12-0.64; P < 0.001). CONCLUSIONS: Ischemic strokes in patients with atrial fibrillation are less often disabling or fatal with LAAC than DOAC prophylaxis.
- MeSH
- antikoagulancia škodlivé účinky MeSH
- cévní mozková příhoda * epidemiologie etiologie prevence a kontrola MeSH
- fibrilace síní * komplikace farmakoterapie chirurgie MeSH
- hemoragická cévní mozková příhoda * chemicky indukované komplikace farmakoterapie MeSH
- ischemická cévní mozková příhoda * chemicky indukované komplikace farmakoterapie MeSH
- krvácení chemicky indukované MeSH
- lidé středního věku MeSH
- lidé MeSH
- retrospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- uzávěr ouška levé síně MeSH
- výsledek terapie MeSH
- warfarin škodlivé účinky MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. OBJECTIVES: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. METHODS: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). RESULTS: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. CONCLUSIONS: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * metody škodlivé účinky MeSH
- koronární angiografie MeSH
- koronární cévy účinky léků chirurgie patofyziologie MeSH
- koronární vazospasmus * prevence a kontrola MeSH
- lidé středního věku MeSH
- lidé MeSH
- nitroglycerin * aplikace a dávkování terapeutické užití MeSH
- senioři MeSH
- vazodilatancia terapeutické užití aplikace a dávkování MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.
- MeSH
- fibrilace síní * diagnóza chirurgie MeSH
- katetrizační ablace * metody MeSH
- kryochirurgie MeSH
- laserová terapie MeSH
- lidé MeSH
- radiofrekvenční ablace MeSH
- recidiva MeSH
- retrospektivní studie MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
BACKGROUND: Obesity is well-appreciated to result in poor cardiovascular and metabolic outcomes. Dietary and medical weight loss strategies are frequently unsuccessful and unsustainable. Bariatric surgery is quite effective, but is reserved for the most obese patients because of the associated intraoperative/post-operative risks. In preclinical and early clinical case series, a novel therapy, transcatheter bariatric embolotherapy (TBE) of the left gastric artery, has been reported to promote weight loss by reducing ghrelin, an appetite-stimulating hormone secreted from the gastric fundus. OBJECTIVES: The purpose of this study was to examine TBE in a single-blind, sham procedure randomized trial. METHODS: Obese subjects (body mass index 35 to 55 kg/m2) were randomized 1:1 to either sham or TBE targeting the left gastric artery using an occlusion balloon microcatheter to administer 300- to 500-μm embolic beads. All patients entered a lifestyle counseling program. Patients and physicians performing follow-up were blind to the allocated therapy. Endoscopy was performed at baseline and 1-week post-procedure. The primary endpoint was 6-month total body weight loss (TBWL). RESULTS: Eligible subjects (n = 44; age 45.5 ± 9.4 years; 8 men/36 women; body mass index 39.6 ± 3.8 kg/m2) were randomized to undergo the sham or TBE procedure with no device-related complications and 1 vascular complication. Patients reported mild nausea and vomiting, and endoscopy revealed only minor self-limiting ulcers in 5 patients. At 6 months, in both the intention-to-treat and per-protocol populations, the TBWL was greater with TBE (7.4 kg/6.4% and 9.4 kg/8.3% loss, respectively) than sham (3.0 kg/2.8% and 1.9 kg/1.8%, respectively; p = 0.034/0.052 and p = 0.0002/0.0011, respectively). The TBWL was maintained with TBE at 12 months (intention-to-treat 7.8 kg/6.5% loss, per-protocol 9.3 kg/9.3% loss; p = 0.0011/0.0008, p = 0.0005/0.0005, respectively). CONCLUSIONS: In this randomized pilot trial, we have established the proof-of-principle that transcatheter bariatric embolotherapy of the left gastric artery is well-tolerated and promotes clinically significant weight loss over a sham procedure.(The Lowering Weight in Severe Obesity by Embolization of the Gastric Artery Trial [LOSEIT]; NCT03185949).
- MeSH
- dospělí MeSH
- gastrická arterie MeSH
- ghrelin krev MeSH
- hlad MeSH
- hypertenze etiologie terapie MeSH
- kvalita života MeSH
- lidé středního věku MeSH
- lidé MeSH
- obezita krev komplikace psychologie terapie MeSH
- odpověď na uspokojení MeSH
- terapeutická embolizace škodlivé účinky metody statistika a číselné údaje MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH