36134574 OR Coronary Arterial Spasm During Pulsed Field Ablation to Treat Atrial Fibrillation Dotaz Zobrazit nápovědu
BACKGROUND: Pulsed field ablation (PFA) has a unique safety profile when used to treat atrial fibrillation, largely related to its preferentiality for myocardial tissue ablation, in particular, esophageal sparing. A pentaspline catheter was the first such PFA system studied clinically for atrial fibrillation ablation; in these initial regulatory trials, the catheter was used for pulmonary vein isolation and left atrial posterior wall ablation. Since its regulatory approval in Europe, in clinical practice, physicians have ablated beyond pulmonary vein isolation and left atrial posterior wall ablation to expanded lesion sets in closer proximity to coronary arteries. This is an unstudied important issue because preclinical and clinical data have raised the potential for coronary arterial spasm. Herein, we studied the vasospastic potential of PFA lesion sets, both remote from and adjacent to coronary arteries. METHODS: During routine atrial fibrillation ablation using the pentaspline PFA catheter, coronary angiography was performed before, during, and after pulsed field applications. The lesion sets studied included: (1) those remote from the coronary arteries such as pulmonary vein isolation (n=25 patients) and left atrial posterior wall ablation (n=5), and (2) ablation of the cavotricuspid isthmus (n=20) that is situated adjacent to the right coronary artery. RESULTS: During pulmonary vein isolation and left atrial posterior wall ablation, coronary spasm did not occur, but cavotricuspid isthmus ablation provoked severe subtotal vasospasm in 5 of 5 (100%) consecutive patients, and this was relieved by intracoronary nitroglycerin in 5.5±3.5 minutes. ST-segment elevation was not observed. However, no patient (0%, P=0.004) had severe spasm if first administered parenteral nitroglycerin, either intracoronary (n=5) or intravenous (n=10), before treatment. CONCLUSIONS: Coronary vasospasm was not provoked during PFA at locations remote from coronary arteries, but when the energy is delivered adjacent to a coronary artery, PFA routinely provokes subclinical vasospasm. This phenomenon is attenuated by nitroglycerin, administered either post hoc to treat spasm or as prophylaxis.
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * škodlivé účinky MeSH
- koronární cévy diagnostické zobrazování chirurgie MeSH
- lidé MeSH
- nitroglycerin terapeutické užití MeSH
- srdeční síně MeSH
- venae pulmonales * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. OBJECTIVES: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. METHODS: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). RESULTS: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. CONCLUSIONS: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * metody škodlivé účinky MeSH
- koronární angiografie MeSH
- koronární cévy účinky léků chirurgie patofyziologie MeSH
- koronární vazospasmus * prevence a kontrola MeSH
- lidé středního věku MeSH
- lidé MeSH
- nitroglycerin * aplikace a dávkování terapeutické užití MeSH
- senioři MeSH
- vazodilatancia terapeutické užití aplikace a dávkování MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
IMPORTANCE: In treating atrial fibrillation, pulsed field ablation (PFA) is a novel energy modality with comparable efficacy to conventional thermal ablation, such as radiofrequency ablation (RFA), but with the benefit of some preferentiality to myocardial tissue ablation. Studies have demonstrated important safety advantages, including the absence of esophageal injury or pulmonary vein stenosis and only rare phrenic nerve injury. However, there is emerging evidence of coronary artery vasospasm provoked by PFA. OBJECTIVE: To compare the incidence and severity of left circumflex arterial vasospasm between PFA and RFA during adjacent ablation along the mitral isthmus. DESIGN, SETTING, AND PARTICIPANTS: This prospective cohort study enrolled consecutive adult patients receiving first-ever PFA or RFA of the mitral isthmus during catheter ablation of atrial fibrillation in 2022 with acute follow-up at a single referral European center. EXPOSURE: A posterolateral mitral isthmus line was created using either a multielectrode pentaspline PFA catheter (endocardial ablation) or a saline-irrigated RFA catheter. Simultaneous diagnostic coronary angiography was performed before, during, and after catheter ablation. Nitroglycerin was planned for spasm persisting beyond 20 minutes or for significant electrocardiographic changes. MAIN OUTCOMES AND MEASURES: The frequency and severity of left circumflex arterial vasospasm was assessed and monitored, as were time to remission and any need for nitroglycerin administration. RESULTS: Of 26 included patients, 19 (73%) were male, and the mean (SD) age was 65.5 (9.3) years. Patients underwent either PFA (n = 17) or RFA (n = 9) along the mitral isthmus. Coronary spasm was observed in 7 of 17 patients (41.2%) undergoing PFA: in 7 of 9 (77.8%) when the mitral isthmus ablation line was situated superiorly and in 0 of 8 when situated inferiorly. Conversely, coronary spasm did not occur in any of the 9 patients undergoing RFA. Of 5 patients in whom crossover PFA was performed after RFA failed to achieve conduction block, coronary spasm occurred in 3 (60%). Most instances of spasm (9 of 10 [90%]) were subclinical, with 2 (20%) requiring nitroglycerin administration. The median (range) time to resolution of spasm was 5 (5-25) minutes. CONCLUSION AND RELEVANCE: When creating a mitral isthmus ablation line during catheter ablation of atrial fibrillation, adjacent left circumflex arterial vasospasm frequently occurred with PFA and not RFA but was typically subclinical.
- MeSH
- dospělí MeSH
- fibrilace síní * chirurgie patofyziologie MeSH
- katetrizační ablace * škodlivé účinky MeSH
- koronární vazospasmus * etiologie MeSH
- lidé MeSH
- nitroglycerin MeSH
- prospektivní studie MeSH
- senioři MeSH
- srdeční síně patofyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- komentáře MeSH