A substantial development in nanoscale materials possessing catalytic activities comparable with natural enzymes has been accomplished. Their advantages were owing to the excellent sturdiness in an extreme environment, possibilities of their large-scale production resulting in higher profitability, and easy manipulation for modification. Despite these advantages, the main challenge for artificial enzyme mimetics is the lack of substrate selectivity where natural enzymes flourish. This review addresses this vital problem by introducing substrate selectivity strategies to three classes of artificial enzymes: molecularly imprinted polymers, nanozymes (NZs), and DNAzymes. These rationally designed strategies enhance the substrate selectivity and are discussed and exemplified throughout the review. Various functional mechanisms associated with applying enzyme mimetics in biosensing and bioassays are also given. Eventually, future directives toward enhancing the substrate selectivity of biomimetics and related challenges are discussed and evaluated based on their efficiency and convenience in biosensing and bioassays.
- Klíčová slova
- Artificial-enzyme mimetics, DNAzymes, Enhanced selectivity, Molecularly-imprinted-polymer, Nanozymes,
- MeSH
- biomimetické materiály * chemie MeSH
- biosenzitivní techniky * metody MeSH
- biotest * MeSH
- DNA katalytická chemie metabolismus MeSH
- enzymy metabolismus chemie MeSH
- lidé MeSH
- molekulárně imprintované polymery chemie MeSH
- substrátová specifita MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- Názvy látek
- DNA katalytická MeSH
- enzymy MeSH
- molekulárně imprintované polymery MeSH
Concerns are growing about adverse effects of progestins on biota, even at ultra-trace concentrations. The enrichment factor (EF) from extraction of analytes in environmental samples that is needed for sample pre-concentration can affect not only performance of the analytical method but also the matrix effect. Therefore, the present study aimed to assess the influence of high sample EF on performance of the high-performance liquid chromatography with atmospheric pressure chemical ionization and photoionization coupled with high-resolution mass spectrometry (HPLC-APCI/APPI-HRMS) method for analysis of progestins in waste water treatment plant (WWTP) effluents and surface waters and analysis of (anti-)progestogenic activities measured by (anti-)PR-CALUX bioassays. The results showed that HPLC-APCI/APPI-HRMS coupled with solid-phase extraction and a high EF (33,333 Lwater/Lextract) enabled the detection of more compounds compared to samples with lower sample EF (10,000 Lwater/Lextract). The matrix effect did not increase proportionally compared to lower EFs (10,000 and 16,666 Lwater/Lextract), and lower limits of quantification were achieved in WWTP effluents and surface waters. The results of bioassays have shown that relative EF of 25 Lwater/Lbioassay appears high enough to detect progestogenic activity in treated waste water. Our study is one of the first to provide insights into sample pre-concentration in analysis of progestins and progestogenicity in aquatic environments.
- Klíčová slova
- Contamination, Contraceptives, In vitro bioassays, Mass spectrometry, Organic micropollutants, Pollutants, Progestogens,
- MeSH
- biotest * MeSH
- chemické látky znečišťující vodu * analýza MeSH
- extrakce na pevné fázi MeSH
- monitorování životního prostředí * metody MeSH
- odpadní voda chemie MeSH
- progestiny * analýza MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- chemické látky znečišťující vodu * MeSH
- odpadní voda MeSH
- progestiny * MeSH
Real-time quaking-induced conversion assay (RT-QuIC) exploits templating activity of pathogenic prion protein for ultrasensitive detection of prions. We have utilized second generation RT-QuIC assay to analyze matching post-mortem cerebrospinal fluid and skin samples of 38 prion disease patients and of 30 deceased neurological controls. The analysis of cerebrospinal fluid samples led to 100% sensitivity and 100% specificity, but some samples had to be diluted before the analysis to alleviate the effect of present RT-QuIC inhibitors. The analysis of the corresponding skin samples provided 89.5% sensitivity and 100% specificity. The median seeding dose present in the skin was one order of magnitude higher than in the cerebrospinal fluid, despite the overall fluorescent signal of the skin samples was comparatively lower. Our data support the use of post-mortem cerebrospinal fluid for confirmation of prion disease diagnosis and encourage further studies of the potential of skin biopsy samples for intra-vitam prion diseases´ diagnostics.
- MeSH
- biotest MeSH
- Creutzfeldtova-Jakobova nemoc * diagnóza mozkomíšní mok MeSH
- kůže metabolismus MeSH
- lidé MeSH
- prionová bílkovina MeSH
- prionové nemoci * diagnóza MeSH
- priony * metabolismus MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- prionová bílkovina MeSH
- priony * MeSH
Bioassays are the main tool to decipher bioactivities from natural resources thus their selection and quality are critical for optimal bioprospecting. They are used both in the early stages of compounds isolation/purification/identification, and in later stages to evaluate their safety and efficacy. In this review, we provide a comprehensive overview of the most common bioassays used in the discovery and development of new bioactive compounds with a focus on marine bioresources. We present a comprehensive list of practical considerations for selecting appropriate bioassays and discuss in detail the bioassays typically used to explore antimicrobial, antibiofilm, cytotoxic, antiviral, antioxidant, and anti-ageing potential. The concept of quality control and bioassay validation are introduced, followed by safety considerations, which are critical to advancing bioactive compounds to a higher stage of development. We conclude by providing an application-oriented view focused on the development of pharmaceuticals, food supplements, and cosmetics, the industrial pipelines where currently known marine natural products hold most potential. We highlight the importance of gaining reliable bioassay results, as these serve as a starting point for application-based development and further testing, as well as for consideration by regulatory authorities.
- Klíčová slova
- Bioactivity, Bioactivity-guided purification, Bioassay selection, Biodiscovery, Blue biotechnology, Drug discovery, Natural products, Preclinical trials, Validation,
- MeSH
- antiinfekční látky * MeSH
- biologické přípravky * farmakologie MeSH
- biotest metody MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- Názvy látek
- antiinfekční látky * MeSH
- biologické přípravky * MeSH
The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-scale radiation accident involving a network of biodosimetry labs. Labs were required to perform their analyses using different biodosimetric assays in triage mode scoring and to rapidly report estimated radiation doses to the organizing institution. This article reports the results obtained with the cytokinesis-block micronucleus assay. Three test samples were exposed to blinded doses of 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 13 mA, ∼75 keV, 1 Gy/min). These doses belong to 3 triage categories of clinical relevance: a low dose category, for no exposure or exposures inferior to 1 Gy, requiring no direct treatment of subjects; a medium dose category, with doses ranging from 1 to 2 Gy, and a high dose category, after exposure to doses higher than 2 Gy, with the two latter requiring increasing medical attention. After irradiation the test samples (no. 1, no. 2 and no. 3) were sent by the organizing laboratory to 14 centers participating in the micronucleus assay exercise. Laboratories were asked to setup micronucleus cultures and to perform the micronucleus assay in triage mode, scoring 500 binucleated cells manually, or 1,000 binucleated cells in automated/semi-automated mode. One laboratory received no blood samples, but scored pictures from another lab. Based on their calibration curves, laboratories had to provide estimates of the administered doses. The accuracy of the reported dose estimates was further analyzed by the micronucleus assay lead. The micronucleus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%). Agreement between scoring laboratories, assessed by calculating the Fleiss' kappa, was excellent (100%) for semi-automated scoring, good (83%) for manual scoring and poor (53%) for fully automated scoring. Correct classification into triage scoring dose intervals (reference dose ±0.5 Gy for doses ≤2.5 Gy, or reference dose ±1 Gy for doses >2.5 Gy), recommended for triage biodosimetry, was obtained in 79% of cases (manual scoring, 73%; semi-automated scoring, 100%; automated scoring, 67%). The percentage of dose estimates whose 95% confidence intervals included the reference dose was 58% (manual scoring, 48%; semiautomated scoring, 72%; automated scoring, 60%). For the irradiated samples no. 2 and no. 3, a systematic shift towards higher dose estimations was observed. This was also noticed with the other cytogenetic assays in this intercomparison exercise. Accuracy of the rapid triage modality could be maintained when the number of manually scored cells was scaled down to 200 binucleated cells. In conclusion, the micronucleus assay, preferably performed in a semi-automated or manual scoring mode, is a reliable technique to perform rapid biodosimetry analysis in large-scale radiation emergencies.
Cultivation-based assays represent the gold standard for the assessment of virus infectivity; however, they are time-consuming and not suitable for every virus type. Pre-treatment with platinum (Pt) compounds followed by real-time PCR has been shown to discriminate between infectious and non-infectious RNA viruses. This study examined the effect of Pt and palladium (Pd) compounds on enveloped DNA viruses, paying attention to two significant pathogens of livestock - bovine herpesvirus-1 (BoHV-1) and African swine fever virus (ASFV). Native or heat-treated BoHV-1 suspension was incubated with the spectrum of Pt/Pd compounds. Bis(benzonitrile)palladium(II) dichloride (BB-PdCl 2) and dichloro(1,5-cyclooctadiene) palladium(II) (PdCl 2-COD) produced the highest differences found between native and heat- -treated viruses. Optimized pre-treatment conditions (1 mM of Pd compound, 15 min, 4°C) were applied on both virus genera and the heat inactivation profiles were assessed. A significant decrease in the detected quantity of BoHV-1 DNA and ASFV DNA after heat-treatment (60°C and 95°C) and consequent incubation with Pd compounds was observed. BB-PdCl 2 and PdCl 2-COD could help to distinguish between infectious and non-infectious enveloped DNA viruses such as BoHV-1 or ASFV.
- Klíčová slova
- African swine fever virus, bovine herpesvirus-1, molecular methods, palladium compounds, viability PCR,
- MeSH
- biotest veterinární MeSH
- bovinní herpesvirus 1 * MeSH
- DNA viry MeSH
- kvantitativní polymerázová řetězová reakce veterinární MeSH
- palladium farmakologie MeSH
- prasata MeSH
- virus afrického moru prasat * genetika MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- palladium MeSH
Tools for radiation exposure reconstruction are required to support the medical management of radiation victims in radiological or nuclear incidents. Different biological and physical dosimetry assays can be used for various exposure scenarios to estimate the dose of ionizing radiation a person has absorbed. Regular validation of the techniques through inter-laboratory comparisons (ILC) is essential to guarantee high quality results. In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays [gamma-H2AX foci (gH2AX), gene expression (GE)] and physical dosimetry-based assays [electron paramagnetic resonance (EPR), optically or thermally stimulated luminescence (LUM)]. Three blinded coded samples (e.g., blood, enamel or mobiles) were exposed to 0, 1.2 or 3.5 Gy X-ray reference doses (240 kVp, 1 Gy/min). These doses roughly correspond to clinically relevant groups of unexposed to low exposed (0-1 Gy), moderately exposed (1-2 Gy, no severe acute health effects expected) and highly exposed individuals (>2 Gy, requiring early intensive medical care). In the frame of the current RENEB inter-laboratory comparison, samples were sent to 86 specialized teams in 46 organizations from 27 nations for dose estimation and identification of three clinically relevant groups. The time for sending early crude reports and more precise reports was documented for each laboratory and assay where possible. The quality of dose estimates was analyzed with three different levels of granularity, 1. by calculating the frequency of correctly reported clinically relevant dose categories, 2. by determining the number of dose estimates within the uncertainty intervals recommended for triage dosimetry (±0.5 Gy or ±1.0 Gy for doses <2.5 Gy or >2.5 Gy), and 3. by calculating the absolute difference (AD) of estimated doses relative to the reference doses. In total, 554 dose estimates were submitted within the 6-week period given before the exercise was closed. For samples processed with the highest priority, earliest dose estimates/categories were reported within 5-10 h of receipt for GE, gH2AX, LUM, EPR, 2-3 days for DCA, CBMN and within 6-7 days for the FISH assay. For the unirradiated control sample, the categorization in the correct clinically relevant group (0-1 Gy) as well as the allocation to the triage uncertainty interval was, with the exception of a few outliers, successfully performed for all assays. For the 3.5 Gy sample the percentage of correct classifications to the clinically relevant group (≥2 Gy) was between 89-100% for all assays, with the exception of gH2AX. For the 1.2 Gy sample, an exact allocation to the clinically relevant group was more difficult and 0-50% or 0-48% of the estimates were wrongly classified into the lowest or highest dose categories, respectively. For the irradiated samples, the correct allocation to the triage uncertainty intervals varied considerably between assays for the 1.2 Gy (29-76%) and 3.5 Gy (17-100%) samples. While a systematic shift towards higher doses was observed for the cytogenetic-based assays, extreme outliers exceeding the reference doses 2-6 fold were observed for EPR, FISH and GE assays. These outliers were related to a particular material examined (tooth enamel for EPR assay, reported as kerma in enamel, but when converted into the proper quantity, i.e. to kerma in air, expected dose estimates could be recalculated in most cases), the level of experience of the teams (FISH) and methodological uncertainties (GE). This was the first RENEB ILC where everything, from blood sampling to irradiation and shipment of the samples, was organized and realized at the same institution, for several biological and physical retrospective dosimetry assays. Almost all assays appeared comparably applicable for the identification of unexposed and highly exposed individuals and the allocation of medical relevant groups, with the latter requiring medical support for the acute radiation scenario simulated in this exercise. However, extreme outliers or a systematic shift of dose estimates have been observed for some assays. Possible reasons will be discussed in the assay specific papers of this special issue. In summary, this ILC clearly demonstrates the need to conduct regular exercises to identify research needs, but also to identify technical problems and to optimize the design of future ILCs.
After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0-1 Gy), moderately (1-2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.
In late 2022, various Omicron subvariants emerged and cocirculated worldwide. These variants convergently acquired amino acid substitutions at critical residues in the spike protein, including residues R346, K444, L452, N460, and F486. Here, we characterize the convergent evolution of Omicron subvariants and the properties of one recent lineage of concern, BQ.1.1. Our phylogenetic analysis suggests that these five substitutions are recurrently acquired, particularly in younger Omicron lineages. Epidemic dynamics modelling suggests that the five substitutions increase viral fitness, and a large proportion of the fitness variation within Omicron lineages can be explained by these substitutions. Compared to BA.5, BQ.1.1 evades breakthrough BA.2 and BA.5 infection sera more efficiently, as demonstrated by neutralization assays. The pathogenicity of BQ.1.1 in hamsters is lower than that of BA.5. Our multiscale investigations illuminate the evolutionary rules governing the convergent evolution for known Omicron lineages as of 2022.
- MeSH
- biotest MeSH
- COVID-19 * MeSH
- fylogeneze MeSH
- křečci praví MeSH
- neutralizující protilátky MeSH
- protilátky virové MeSH
- SARS-CoV-2 genetika MeSH
- substituce aminokyselin MeSH
- zvířata MeSH
- Check Tag
- křečci praví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- neutralizující protilátky MeSH
- protilátky virové MeSH
In comparison with analytical tools, bioassays provide higher sensitivity and more complex evaluation of environmental samples and are indispensable tools for monitoring increasing in anthropogenic pollution. Nevertheless, the disadvantage in cellular assays stems from the material variability used within the assays, and an interlaboratory adaptation does not usually lead to satisfactory test sensitivities. The aim of this study was to evaluate the influence of material variability on CXCL12 secretion by T47D cells, the outcome of the CXCL-test (estrogenic activity assay). For this purpose, the cell line sources, sera suppliers, experimental and seeding media, and the amount of cell/well were tested. The multivariable linear model (MLM), employed as an innovative approach in this field for parameter evaluation, identified that all the tested parameters had significant effects. Knowledge of the contributions of each parameter has permitted step-by-step optimization. The most beneficial approach was seeding 20,000 cells/well directly in treatment medium and using DMEM for the treatment. Great differences in both basal and maximal cytokine secretions among the three tested cell lines and different impacts of each serum were also observed. Altogether, both these biologically based and highly variable inputs were additionally assessed by MLM and a subsequent two-step evaluation, which revealed a lower variability and satisfactory reproducibility of the test. This analysis showed that not only parameter and procedure optimization but also the evaluation methodology must be considered from the perspective of interlaboratory method adaptation. This overall methodology could be applied to all bioanalytical methods for fast multiparameter and accurate analysis.
- Klíčová slova
- T47D, cytokine CXCL12/SDF1, estrogenic activity cellular assay, material variability, multivariate linear model (MLM),
- MeSH
- biotest MeSH
- buněčné linie MeSH
- chemické látky znečišťující vodu * MeSH
- estrogeny * toxicita MeSH
- estron MeSH
- lineární modely MeSH
- monitorování životního prostředí metody MeSH
- reprodukovatelnost výsledků MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- chemické látky znečišťující vodu * MeSH
- estrogeny * MeSH
- estron MeSH