OBJECTIVES: This cross-sectional analysis from the CZecking Heart Failure in patients with advanced Chronic Kidney Disease trial (ISRCTN18275480) examined pulmonary hypertension and right ventricular-pulmonary arterial coupling in patients on chronic hemodialysis. The aims of this analysis were: 1. To analyze relations between pulmonary hypertension and right ventricular-pulmonary arterial coupling with dialysis access flow and current hydration; 2. To analyze structural heart changes associated with right ventricular-pulmonary arterial uncoupling; 3. To reveal the prevalence, etiology and severity of pulmonary hypertension in the Czech hemodialysis population. METHODS: We performed expert echocardiography, vascular access flow measurements, bioimpedance analysis, and laboratory testing in 336 hemodialysis patients. RESULTS: Pulmonary hypertension was present in 34% (114/336) patients and right ventricular-pulmonary arterial uncoupling was present in 25% of patients with pulmonary hypertension. Only weak associations between the flow of the dialysis arteriovenous access and estimated pulmonary arterial systolic pressure and right ventricular-pulmonary arterial coupling was proved. There was a strong association between hydration status assessed by estimated central venous pressure with pulmonary arterial systolic pressure (Rho 0.6, p < 0.0001) and right ventricular-pulmonary arterial coupling (Rho -0.52, p < 0.0001) and association between overhydration to extracellular water ratio with pulmonary arterial systolic pressure (Rho 0.31, p = 0.0001) and right ventricular-pulmonary arterial coupling (Rho -0.29, p = 0.002). The prevalence of heart failure was significantly higher in patients with right ventricular-pulmonary arterial uncoupling (88% vs. 52%, p = 0.0003). CONCLUSION: These findings suggest that optimizing volume status and treating heart failure should be prioritized in hemodialysis patients to prevent pulmonary hypertension progression and right ventricular-pulmonary arterial uncoupling.
- Klíčová slova
- Right ventricular-pulmonary arterial coupling, arteriovenous access flow, chronic hemodialysis, fluid overload, heart failure, pulmonary hypertension,
- MeSH
- arteria pulmonalis * patofyziologie MeSH
- chronické selhání ledvin * terapie komplikace patofyziologie MeSH
- dialýza ledvin * škodlivé účinky MeSH
- echokardiografie MeSH
- lidé středního věku MeSH
- lidé MeSH
- plicní hypertenze * etiologie patofyziologie MeSH
- průřezové studie MeSH
- senioři MeSH
- srdeční komory patofyziologie diagnostické zobrazování MeSH
- srdeční selhání patofyziologie komplikace etiologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
A case report of a 68-year-old otherwise-healthy female patient with Spetzler-Martin (SM) grade I arteriovenous malformation (AVM) in her left frontal region is presented. After an uneventful surgery, cerebral venous infarction developed, and the patient was rendered hemiparetic with motor aphasia. After bony decompression, slow improvement was seen, and 3 months after surgery, the patient was neurologically intact. Six months after AVM resection, cranioplasty was performed. Infarction was caused by the thrombosis of a long primary draining vein, which finished its course in the normal cortical venous system. The case supports the venous origin of postoperative bleeding after AVM resection instead of the normal perfusion pressure phenomenon.
- Klíčová slova
- Cerebral arteriovenous malformation, venous occlusive disease,
- MeSH
- cerebrální infarkt * etiologie chirurgie MeSH
- intrakraniální arteriovenózní malformace * chirurgie komplikace MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- mozkové žíly chirurgie diagnostické zobrazování MeSH
- pooperační komplikace etiologie chirurgie MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
BACKGROUND: The integration of robotic technology into surgical procedures has gained considerable attention for its promise to enhance a variety of clinical outcomes. Robotic deep inferior epigastric perforator (DIEP) flap harvest has emerged as a novel approach for autologous breast reconstruction. This systematic review aims to provide a comprehensive overview of the current techniques, outcomes, and complications of robotic DIEP flap surgery. METHODS: A systematic literature search was conducted after PRISMA 2020 guidelines across databases including PubMed, Embase, Google Scholar, and Web of Science from 2000 to 2023. Articles exploring robotic DIEP flap harvest for breast reconstruction were assessed to compare operative techniques, clinical outcomes, and complications. The risk of bias was evaluated using ROBINS-I and the Newcastle-Ottawa scale. RESULTS: Fourteen studies involving 108 patients were included. Three studies used a totally extraperitoneal (TEP) technique, whereas 11 studies used a transabdominal preperitoneal (TAPP) approach. Preoperative planning utilized computed tomography angiography and magnetic resonance angiography imaging. The mean robotic operative time was 64 minutes, with total operative times averaging 574 minutes for TAPP and 497 minutes for TEP. The mean length of stay was 5 days, and the mean fascial incision length was 3 cm. Overall complication rate was 14.9%, with no significant difference compared with conventional DIEP flap procedures. CONCLUSION: Robotic DIEP flap harvest is a promising technique that may reduce postoperative pain and limiting abdominal donor site morbidity. Potential limitations include longer operative times, variable hospital stays, and increased costs.
- MeSH
- arteriae epigastricae * transplantace MeSH
- délka operace * MeSH
- délka pobytu MeSH
- lidé MeSH
- mamoplastika * metody MeSH
- odběr tkání a orgánů metody MeSH
- perforátorový lalok * krevní zásobení MeSH
- pooperační komplikace prevence a kontrola MeSH
- roboticky asistované výkony * metody MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- systematický přehled MeSH
Infective endocarditis (IE) is a life-threatening disease, with its mortality rate varying depending on the infectious agent. Streptococci are among the most common causes of infective endocarditis. However, Streptococcus vestibularis has rarely been associated with human infections, typically affecting patients with underlying conditions such as immunosuppressive diseases, valve replacement, rheumatic heart disease, and hemodialysis. We present the case of a 26-year-old man who presented with fever, unanticipated weight loss, and fatigue. Although no typical risk factors for infective endocarditis were identified at admission, transesophageal echocardiography revealed a bicuspid aortic valve with calcification, paravalvular aortic abscess formation, and vegetations on the anterior leaflet of the mitral valve. Blood cultures grew S. vestibularis, which was initially sensitive to benzylpenicillin but developed emergent resistance on the third day of the antibiotic treatment. Subsequently, ceftriaxone therapy was initiated, and blood cultures became sterile on day 10. The patient eventually underwent aortic valve replacement. We report the first known case of native aortic and mitral valve endocarditis caused by S. vestibularis, accompanied by a paravalvular abscess around the native aortic valve, in a patient who had no typical risk factors for infective endocarditis, except for a bicuspid aortic valve.
- Klíčová slova
- Bicuspid aortic valves, Infective endocarditis, Periannular abscesses, Streptococcus vestibularis,
- MeSH
- aortální chlopeň * MeSH
- bakteriální endokarditida * diagnóza mikrobiologie komplikace MeSH
- dospělí MeSH
- lidé MeSH
- mitrální chlopeň * MeSH
- Streptococcus * izolace a purifikace MeSH
- streptokokové infekce * diagnóza komplikace MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
Permeability is an important molecular property in drug discovery, as it co-determines pharmacokinetics whenever a drug crosses the phospholipid bilayer, e.g., into the cell, in the gastrointestinal tract, or across the blood-brain barrier. Many methods for the determination of permeability have been developed, including cell line assays (CACO-2 and MDCK), cell-free model systems like parallel artificial membrane permeability assay (PAMPA) mimicking, e.g., gastrointestinal epithelia or the skin, as well as the black lipid membrane (BLM) and submicrometer liposomes. Furthermore, many in silico approaches have been developed for permeability prediction: meta-analysis of publicly available databases for permeability data (MolMeDB and ChEMBL) was performed to establish their usability. Four experimental and two computational methods were evaluated. It was shown that repeatability of the reported permeability measurement is not great even for the same method. For the PAMPA method, two different permeabilities are reported: intrinsic and apparent. They can vary in degrees of magnitude; thus, we suggest being extra cautious using literature data on permeability. When we compared data for the same molecules using different methods, the best agreement was between cell-based methods and between BLM and computational methods. Existence of unstirred water layer (UWL) permeability limits the data agreement between cell-based methods (and apparent PAMPA) with data that are not limited by UWL permeability (computational methods, BLM, intrinsic PAMPA). Therefore, different methods have different limitations. Cell-based methods provide results only in a small range of permeabilities (-8 to -4 in cm/s), and computational methods can predict a wider range of permeabilities beyond physical limitations, but their precision is therefore limited. BLM with liposomes can be used for both fast and slow permeating molecules, but its usage is more complicated than standard transwell techniques. To sum up, when working with in-house measured or published permeability data, we recommend caution in interpreting and combining them.
- Klíčová slova
- BLM, CACO-2, COSMOperm, MDCK, MolMeDB, PAMPA, PerMM, liposome, membrane, permeability,
- MeSH
- buňky MDCK MeSH
- Caco-2 buňky MeSH
- hematoencefalická bariéra metabolismus MeSH
- lidé MeSH
- liposomy * chemie MeSH
- membrány umělé MeSH
- permeabilita buněčné membrány fyziologie MeSH
- permeabilita * MeSH
- psi MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- psi MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- Názvy látek
- liposomy * MeSH
- membrány umělé MeSH
Carotid plaque composition represents one of the main risk factors of future ischemic stroke. MRI provides excellent soft tissue contrast that can distinguish plaque characteristics. Our objective was to analyze the diagnostic accuracy of MRI imaging in the detection of carotid plaque characteristics compared to histology in patients with symptomatic and asymptomatic carotid atherosclerosis through a systematic review. After prospective registration in PROSPERO (ID CRD42022329690), Medline Ovid, Embase.com, Cochrane Library, and Web of Science Core were searched without any search limitation up to May 27, 2022 to identify eligible articles. Of the 8168 studies, 53 (37 × 1.5 T MRI, 17 × 3 T MRI) evaluated MRI accuracy in the detection of 13 specific carotid plaque characteristics in 169 comparisons. MRI demonstrated high diagnostic accuracy for detection of calcification (3 T MRI: mean sensitivity 92%/mean specificity 90%; 1.5 T MRI: mean sensitivity 81%/mean specificity 91%), fibrous cap (1.5 T: 89%/87%), unstable plaque (1.5 T: 89%/87%), intraplaque hemorrhage (1.5 T: 86%/88%), and lipid-rich necrotic core (1.5 T: 89%/79%). MRI also proved to have a high level of tissue discrimination for the carotid plaque characteristics investigated, allowing potentially for a better risk assessment and follow-up of patients who may benefit from more aggressive treatments. These results emphasize the role of MRI as the first-line imaging modality for comprehensive assessment of carotid plaque morphology, particularly for unstable plaque. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.
- Klíčová slova
- atherosclerosis, carotid plaque, carotid stenosis, diagnostic accuracy, intraplaque hemorrhage, lipid‐rich necrotic core,
- MeSH
- arteriae carotides * diagnostické zobrazování patologie MeSH
- aterosklerotický plát * diagnostické zobrazování MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- nemoci arterie carotis * diagnostické zobrazování patologie MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- srovnávací studie MeSH
- systematický přehled MeSH
BACKGROUND: Excess fluid in the interstitium can adversely affect the microcirculation. We studied how gradual dilution of the blood plasma by crystalloid fluid influences microcirculatory variables and capillary filtration in 20 patients undergoing surgery. METHODS: Video recordings of the sublingual mucosal were made on four occasions during the surgery and compared with quasi-measurements of the capillary filtration rate using retrospective volume kinetic data collected over 5-10-minute periods during 262 infusion experiments with crystalloid fluid. RESULTS: The number of crossings (vessel density) increased up to plasma dilution of 15-20 % whereafter it decreased. The proportion of the vessels that were perfused (PPV) decreased and reached a nadir of -15 % at a dilution of 20-30 %. Changes in the number of crossings and the PPV correlated (r = 0.62, P < 0.001) but the curve was displaced so that crossings showed no change when PPV had decreased by approximately 10 %. However, the PPV of vessels with a thickness of ≤25 μm increased or remained constant in the dilution range of up to 20 %. The volume kinetic analysis showed that the capillary filtration was greater than expected from proportionality with the volume expansion up to a plasma dilution of 15 %, the greatest difference (+89 %) being for plasma dilution up to 5 %. CONCLUSION: Plasma dilution of up to 15 % increased the vessel density, and the capillary filtration increased by more than suggested by the volume expansion. Dilution >15 % had a negative influence on these variables.
- Klíčová slova
- Crystalloid fluid, Microvessel density, Pharmacokinetics, Plasma dilution,
- MeSH
- audiovizuální záznam MeSH
- časové faktory MeSH
- dospělí MeSH
- hemodiluce * MeSH
- isotonické roztoky aplikace a dávkování MeSH
- kapilární permeabilita MeSH
- kapiláry patofyziologie MeSH
- kinetika MeSH
- krystaloidní roztoky * aplikace a dávkování MeSH
- lidé středního věku MeSH
- lidé MeSH
- mikrocirkulace * MeSH
- regionální krevní průtok MeSH
- retrospektivní studie MeSH
- rychlost toku krve MeSH
- senioři MeSH
- ústní sliznice krevní zásobení MeSH
- ústní spodina krevní zásobení MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- isotonické roztoky MeSH
- krystaloidní roztoky * MeSH
OBJECTIVES: To analyze the prevalence and severity of fetal aortic regurgitation (AR) after undergoing successful fetal aortic valvuloplasty (FAV) and to evaluate its effects on fetal circulation and left ventricular (LV) growth. METHODS: This was a retrospective review of all fetuses with critical aortic stenosis who underwent successful FAV at our center between 2010 and 2024 for whom postnatal echocardiograms were available in digital format. Fetal and postnatal echocardiographic examinations were analyzed for ventricular and valvular dimensions and characteristics, and Z-scores were calculated for middle cerebral artery (MCA) pulsatility index (PI), umbilical artery (UA) PI and cerebroplacental ratio. AR severity was classified into no/mild AR or significant (moderate/severe) AR. The balloon-to-aortic valve ratio (BVR) was calculated as the ratio between the maximum actual balloon diameter and the aortic valve (AV) annulus diameter. The primary endpoints of this study were the prevalence, severity and risk factors for fetal AR following successful FAV. RESULTS: Ninety-nine fetuses who underwent successful FAV were included. Immediate post-FAV echocardiograms showed that 87% of fetuses developed some degree of AR, including 45% of all fetuses with significant AR. BVR was significantly higher in fetuses with significant AR compared to those with no/mild AR (mean, 1.09 (95% CI, 1.06-1.12) vs 1.02 (95% CI, 0.99-1.04); P < 0.001). In a subgroup of 66/99 fetuses with available postnatal echocardiograms, the prevalence of AR decreased significantly from 86% before birth to 58% after birth (P < 0.001), with the proportion of fetuses with significant AR reducing from 47% before birth to 17% after birth (P < 0.001). In the overall cohort of fetuses, AV maximum velocity (Vmax) increased significantly from post-FAV to after birth (mean, 1.93 (95% CI, 1.75-2.11) m/s vs 3.21 (95% CI, 2.89-3.55) m/s; P < 0.001), regardless of AR severity, but Vmax after birth was lower in the significant-AR group compared with the no/mild-AR group (mean, 2.85 m/s vs 3.55 m/s; P = 0.020). Fetuses with significant AR exhibited higher relative LV length increases from immediately post-FAV to after birth than did those with no/mild AR (25% (95% CI, 16-33%) vs 14% (95% CI, 6-21%); P = 0.044), although there was no significant difference in mean LV length Z-score after birth between the two groups. FAV led to significant short-term increases in MCA-PI and UA-PI Z-scores, with greater increases observed in fetuses with significant AR. CONCLUSIONS: FAV is associated with a high prevalence of fetal AR, which lessens in severity over the course of gestation. Significant fetal AR had the largest association with greater BVR and had significant impact on fetal hemodynamics. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- Klíčová slova
- aortic regurgitation, critical aortic stenosis, evolving hypoplastic left heart syndrome, fetal cardiac intervention, fetal circulation,
- MeSH
- aortální chlopeň diagnostické zobrazování embryologie MeSH
- aortální insuficience * diagnostické zobrazování epidemiologie patofyziologie MeSH
- aortální stenóza diagnostické zobrazování embryologie epidemiologie patofyziologie MeSH
- balónková valvuloplastika * MeSH
- dospělí MeSH
- echokardiografie metody MeSH
- fetální srdce diagnostické zobrazování patofyziologie MeSH
- gestační stáří MeSH
- lidé MeSH
- nemoci plodu epidemiologie diagnostické zobrazování MeSH
- novorozenec MeSH
- prevalence MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- stupeň závažnosti nemoci MeSH
- těhotenství MeSH
- ultrasonografie prenatální * MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- novorozenec MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Fibroblast growth factor 21 (FGF21), a metabolic hormone with pleiotropic effects, is beneficial for various cardiac disorders. However, FGF21's role in heart failure with preserved ejection fraction (HFpEF) remains unclear. Here, we show that elevated circulating FGF21 levels are negatively associated with cardiac diastolic function in patients with HFpEF. Global or adipose FGF21 deficiency exacerbates cardiac diastolic dysfunction and damage in high-fat diet (HFD) plus N[w]-nitro-L-arginine methyl ester (L-NAME)-induced HFpEF mice, whereas these effects are notably reversed by FGF21 replenishment. Mechanistically, FGF21 enhances the production of adiponectin (APN), which in turn indirectly acts on cardiomyocytes, or FGF21 directly targets cardiomyocytes, to negatively regulate pyruvate dehydrogenase kinase 4 (PDK4) production by activating PI3K/AKT signals, then promoting mitochondrial bioenergetics. Additionally, APN deletion strikingly abrogates FGF21's protective effects against HFpEF, while genetic PDK4 inactivation markedly mitigates HFpEF in mice. Thus, FGF21 protects against HFpEF via fine-tuning the multiorgan crosstalk among the adipose, liver, and heart.
- MeSH
- adiponektin * metabolismus genetika MeSH
- dieta s vysokým obsahem tuků * škodlivé účinky MeSH
- energetický metabolismus * účinky léků MeSH
- fibroblastové růstové faktory * metabolismus genetika MeSH
- fosfatidylinositol-3-kinasy metabolismus MeSH
- kardiomyocyty * metabolismus účinky léků MeSH
- lidé MeSH
- myši inbrední C57BL MeSH
- myši knockoutované MeSH
- myši MeSH
- PDH-kinasa * metabolismus genetika MeSH
- protoonkogenní proteiny c-akt metabolismus MeSH
- signální transdukce MeSH
- srdeční mitochondrie * metabolismus účinky léků MeSH
- srdeční selhání * metabolismus prevence a kontrola genetika MeSH
- tepový objem účinky léků MeSH
- tuková tkáň metabolismus MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- adiponektin * MeSH
- FGF21 protein, human MeSH Prohlížeč
- fibroblast growth factor 21 MeSH Prohlížeč
- fibroblastové růstové faktory * MeSH
- fosfatidylinositol-3-kinasy MeSH
- PDH-kinasa * MeSH
- Pdk4 protein, mouse MeSH Prohlížeč
- protoonkogenní proteiny c-akt MeSH
BACKGROUND: The medial approach for minimally invasive harvesting of a deep circumflex iliac artery (DCIA) flap is described for reconstruction of the jaw. The associated preservation of the crest of the ilium prevents the raising of the abdominal internal oblique muscle (IO) in a standard fashion. However, reconstructive surgery of composite mandibular defects includes bone and soft tissue. To achieve this goal, we combined this technique with a new perforator-based raising of the IO for reconstruction of intraoral soft tissue. METHODS: In this study, we present eight cases of patients with composite mandibular defects who underwent the myo-osseous DCIA flap procedure with an IO perforator. Virtual surgical planning was employed to preplan the size and configuration of the graft. Cutting guides were made using CAD/CAM technology. The surgical procedure followed the described medial approach for minimally invasive harvesting, leaving the iliac crest, spine, and skin intact. In addition, we completely cut and isolated the IO with its sole attachment being the ascending branch of the DCIA. We used either a surgical guide with a slot to lead through both the transverse branch of the bone and the ascending branch of the IO or a surgical guide consisting of 2 parts. RESULTS: In all instances, the flap successfully survived with a 100% success rate. There were no signs of infection, wound opening, or bleeding in either patient. Furthermore, the patients did not exhibit permanent complications related to the donor site. The internal oblique perforator flap exhibited remarkable integration in all patients and underwent rapid transformation. Notably, the flap developed keratinized mucosa (KM) that closely resembled the attached gingiva. CONCLUSION: Our study demonstrated the effectiveness of a medial approach for harvesting a newly designed more flexible chimeric myo-osseous deep circumflex iliac artery flap. By incorporating virtual surgical planning and custom-made cutting guides for obtaining deep circumflex iliac artery flaps through the medial route along with an internal oblique perforator flap, we have established a highly promising method for the rehabilitation of patients with composite mandibular defects. This approach not only improves functional outcomes, but also enhances aesthetic results to maintain patients' quality of life.
- MeSH
- arteria iliaca chirurgie MeSH
- chirurgické laloky MeSH
- design s pomocí počítače MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mandibula chirurgie MeSH
- miniinvazivní chirurgické výkony metody MeSH
- os ilium chirurgie MeSH
- senioři MeSH
- zákroky plastické chirurgie * metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH