Most cited article - PubMed ID 22543545
Variation of distances from mid-urethra to the obturator foramen: an MRI study
INTRODUCTION AND HYPOTHESIS: The aim of this study was to assess the length of adjustable single-incision midurethral tape (SIMS; Ajust), which is needed to fix this tape to the obturator membrane. From these data, we can deduce the optimal length of the SIMS. METHODS: For this study, we employed the intra-operative data of patients included in a single-center randomized trial comparing the efficacy of Tension free vaginal tape obturator (TVT-O) and Ajust. The length of the Ajust tape was calculated using the formula: total length of the tape minus the length of the stylet used for the tape lock, minus the length of the lock minus the width of the two anchors. The length of the obturator tape was calculated using the formula: total tape length minus the snipped parts of the tape. The correlation coefficient of the tape length to basic biometric parameters, such as height, weight, and body mass index, was calculated. RESULTS: For this study, data from 50 women from each group, TVT-O and Ajust, were used. The mean length of the Ajust tape inside the body is 11.6 cm (SD 0.9), with a minimum length of 9.6 cm and a maximum length of 14.6 cm. The mean length of TVT-O tape inside the body is 20.3 cm (SD 2.1), with a minimum of 14.8 cm and a maximum length of 24.5 cm. CONCLUSIONS: This study demonstrates that to achieve continence it is necessary to use different lengths of single-incision tape. Inappropriate SIMS length could cause failure related to the tape itself and not to the TVT technique.
- Keywords
- Ajust, Single-incision midurethral sling, Stress urinary incontinence, Surgical treatment, TVT-O,
- MeSH
- Surgical Wound MeSH
- Middle Aged MeSH
- Humans MeSH
- Aged MeSH
- Urinary Incontinence, Stress surgery MeSH
- Suburethral Slings * MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Randomized Controlled Trial MeSH
INTRODUCTION AND HYPOTHESIS: The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. METHODS: Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. RESULTS: Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. CONCLUSIONS: No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.
- Keywords
- Anatomy, Cadaver study, Complications, Sling fixation, TVT ABBREVO, Urogynecology,
- MeSH
- Gynecologic Surgical Procedures instrumentation MeSH
- Muscle, Skeletal * MeSH
- Humans MeSH
- Suburethral Slings * MeSH
- Check Tag
- Humans MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
INTRODUCTION AND HYPOTHESIS: The objective was to describe the fixation site of the anchor of the Ajust mid-urethral minisling. METHODS: This cadaveric study was based on a group of 11 formalin-embalmed bodies with legs positioned in 30° flexion and 30° abduction, and a group of five fresh-frozen bodies with legs positioned as normal during the procedure. The groups were later compared. The fixation site was dissected and described. The distance to the obturator bundle was considered as the primary safety parameter. To compare the groups of fresh-frozen bodies and formalin-embalmed bodies, the Student's t test and Mann-Whitney test were used. RESULTS: In the group of formalin-embalmed bodies the mean distance from the anchoring device to the obturator nerve was 4.23 cm. In 19 cases out of 22 the anchor was within the complex of the obturator membrane and obturator muscles. In the group of fresh frozen bodies the mean distance to the obturator nerve was 3.15 cm. In 9 cases out of 10 the anchor was in the complex of the obturator membrane and obturator muscles. CONCLUSION: The distance from the anchor to the obturator nerve was more than 2 cm in all cases. Correct placement in the obturator membrane was achieved in 65.6 % of cases. In 87.5 % of cases the anchor was placed within the complex of obturator membrane and obturator muscles.
- MeSH
- Embalming MeSH
- Dissection MeSH
- Prosthesis Implantation methods MeSH
- Cryopreservation MeSH
- Humans MeSH
- Cadaver MeSH
- Obturator Nerve anatomy & histology MeSH
- Pelvis anatomy & histology MeSH
- Patient Positioning MeSH
- Prosthesis Retention * MeSH
- Suburethral Slings * MeSH
- Check Tag
- Humans MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH