Nejvíce citovaný článek - PubMed ID 26892466
Electrophysiological findings after surgical thoracoscopic atrial fibrillation ablation
BACKGROUND: Atrial fibrillation is common in patients with structural heart disease who are undergoing cardiac surgery. Surgical CryoMaze has been shown to be an effective treatment in several trials, but success rates have varied considerably, between 47-95%. The sequential hybrid approach, combining surgical CryoMaze followed by radiofrequency catheter ablation, can achieve high freedom from atrial arrhythmias. However, in patients with concomitant surgical atrial fibrillation treatment, data comparing the hybrid approach to CryoMaze alone are lacking. METHODS: The SurHyb study was designed as a prospective, open-label, multicentre randomized trial. Patients with non-paroxysmal atrial fibrillation who were scheduled for coronary artery bypass grafting or valve repair/replacement were randomized to either surgical CryoMaze alone or surgical CryoMaze followed by radiofrequency catheter ablation 3 months post-surgery. The primary outcome measure was arrhythmia-free survival without class I or III antiarrhythmic drugs, which has been evaluated using implantable cardiac monitors. CONCLUSIONS: This is the first randomized study that compares concomitant surgical CryoMaze alone with the staged hybrid surgical CryoMaze followed by catheter ablation, in patients with non-paroxysmal atrial fibrillation using rigorous rhythm monitoring. The results may contribute to the optimization of the treatment in patients undergoing concomitant CryoMaze for atrial fibrillation.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, Cryomaze, Hybrid treatment,
- MeSH
- antiarytmika terapeutické užití MeSH
- fibrilace síní * chirurgie farmakoterapie MeSH
- kardiochirurgické výkony * metody MeSH
- katetrizační ablace * metody MeSH
- lidé MeSH
- multicentrické studie jako téma MeSH
- prospektivní studie MeSH
- randomizované kontrolované studie jako téma MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- protokol klinické studie MeSH
- Názvy látek
- antiarytmika MeSH
BACKGROUND: Hybrid ablation [thoracoscopic ablation (TA) of atrial fibrillation (AF) followed by catheter ablation (CA)] is an increasingly common method of the treatment for patients with AF. The aim of this study was to assess the response to ganglionated plexi (GP) ablation in patients with a previous TA (i.e., to assess whether TA had resulted in damage to the GP. Heart rate variability (HRV) was used as a marker of the autonomic response. METHODS: Twenty AF patients underwent pulmonary vein isolation (PVI) plus GP ablation (GP group) and 18 AF patients underwent CA including GP ablation as a part of hybrid ablation (i.e., all patients had undergone a previous TA; Hybrid group). In each group, a 5 min electrocardiogram (ECG) obtained before and after the CA were analyzed. Time and frequency domain parameters were evaluated. RESULTS: Vagal responses (VR) during CA were observed in 12 (60%) patients in the GP group; however, in the Hybrid group, VR was not observed in any of the patients during CA. The change in normalized power in the low frequency (LF) component and the ratio between the LF and high frequency (LF/HF ratio) components of the HRV spectra, before and after ablation, were statistically significant in the GP group (3.3±2.6 before vs. 1.8±1.9 after ablation) but unchanged, before or after CA, in the Hybrid group. CONCLUSIONS: GP ablation in patients subsequent to TA has a little influence on HRV parameters, which could be explained by GP damage during the preceding TA.
- Klíčová slova
- Ganglionated plexi (GP), atrial fibrillation (AF), heart rate variability (HRV), hybrid ablation,
- Publikační typ
- časopisecké články MeSH
PURPOSE: Hybrid ablation of atrial fibrillation (AF) is a promising treatment strategy for patients with non-paroxysmal AF, although, data regarding mid-term outcomes are limited. METHODS: Patients with persistent or long-standing persistent AF were enrolled. Initially, a thoracoscopic, right-sided, epicardial ablation was performed, with a goal of creating a box lesion on the posterior wall of the left atrium; a novel versapolar radiofrequency (RF) catheter was used. In patients enrolled later, occlusion of the left atrial appendage was also performed. An endocardial procedure was performed 2-4 months later, with the goal of confirming/completing the box lesion and ablating the ganglionated plexi and cavotricuspid isthmus. Efficacy was assessed using multiple 24-h and 1-week Holter monitoring. Analysis was performed to search for variables associated with procedure's failure. RESULTS: Forty-one patients (14 persistent and 27 long-standing persistent AF) were enrolled with a mean AF duration of 33.5 ± 33.1 months. Mean follow-up was 507.2 ± 201.1 days (180-731). At the last follow-up visit, 27(65%) patients were arrhythmia-free, without anti-arrhythmics or need for re-ablation. Additional 4 patients (9.8%) were in sinus rhythm (SR) following re-ablation of postprocedural peri-mitral flutter and 4 (9.8%) were in SR on anti-arrhythmics. Longer periods of preoperative AF were independently associated with worse arrhythmia-free survival (p = 0.015). Serious postoperative complications occurred in 3 (7.3%) patients; only 1 (2.4%) patient had clinical consequences after 6 months. CONCLUSIONS: Hybrid ablation of non-paroxysmal AF using a novel, versapolar RF device yields promising mid-term results. Better arrhythmia-free survival rates were found in AF patients with shorter AF duration.
- Klíčová slova
- Atrial fibrillation, Hybrid ablation, Long-standing persistent, Persistent, Versapolar device,
- MeSH
- bezpečnost vybavení MeSH
- časové faktory MeSH
- chronická nemoc MeSH
- design vybavení MeSH
- elektrokardiografie ambulantní metody MeSH
- elektrokardiografie metody MeSH
- fibrilace síní diagnostické zobrazování chirurgie MeSH
- hodnocení rizik MeSH
- katetrizační ablace přístrojové vybavení metody MeSH
- kohortové studie MeSH
- lidé středního věku MeSH
- lidé MeSH
- monitorování fyziologických funkcí přístrojové vybavení metody MeSH
- následné studie MeSH
- recidiva MeSH
- retrospektivní studie MeSH
- senioři MeSH
- stupeň závažnosti nemoci MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
The midterm efficacy of hybrid ablation of atrial fibrillation (AF) reported in recent papers is about 70% in terms of sinus rhythm maintenance without antiarrhythmic drugs. Bearing in mind that the majority of patients enrolled are patients with persistent and long-standing persistent AF, the reported efficacies seem to be very good. Despite the high efficacies, safety remains a critical issue in hybrid, and especially thoracoscopic ablations. The frequency of complications during thoracoscopic ablations is more than 10% in the majority of reports. Most are short-term with no sequelae (such as pneumothorax or pneumonia); however, life-threatening complications have also been described, e.g., a sternotomy in response to a laceration of the left atrium (LA). One of the most serious ablation complications is stroke. The rate of strokes, which has been reported during or shortly after thoracoscopic ablation, seems to be higher than the rate reported after catheter ablation. This is especially true in papers describing thoracoscopic ablations that were not immediately followed by a catheter ablation. A possible explanation is differences in anticoagulation management during the two procedures. During catheter endocardial procedures, a standard anticoagulation protocol exists and is routinely applied; however, there is no such set of recommendations for anticoagulation during the thoracoscopic-phase of an ablation. It seems probable that, in many cases, no anticoagulation is used during thoracoscopic ablations. Moreover, whatever anticoagulation protocol is used during thoracoscopic ablations often goes unreported. A discussion about the best anticoagulation strategy during thoracoscopic ablation is urgently needed. In the future, standards of anticoagulation during thoracoscopic ablation should be clearly reported, just as they are now for catheter ablations.
- Klíčová slova
- Hybrid ablation, anticoagulation, long-lasting persistent atrial fibrillation (AF), persistent atrial fibrillation (AF), stroke, thoracoscopic ablation,
- Publikační typ
- komentáře MeSH
- úvodníky MeSH