Most cited article - PubMed ID 27232919
Biphasic response in number of stem cells and endothelial progenitor cells after left ventricular assist device implantation: A 6month follow-up
AIMS: Recipients of left ventricular assist devices (LVAD) are exposed to increased risk of adverse clinical events. One of the potential contributing factors is non-pulsatile flow generated by LVAD. We evaluated the association of flow patterns in carotid arteries and of increased arterial stiffness with death and cerebrovascular events in LVAD recipients. METHODS AND RESULTS: We analysed data from 83 patients [mean age 54 ± 15 years; 12 women; HeartMate II (HMII), n = 34; HeartMate 3 (HM3), n = 49]. Pulsatile and resistive indexes, atherosclerotic changes in carotid arteries (measured by duplex ultrasound), and arterial stiffness [measured by Endo-PAT 2000 as the augmentation index standardized for heart rate (AI@75)] were evaluated 3 and 6 months after LVAD implantation. Sixteen patients died during follow-up (27.3 months; interquartile range 15.7-44.3). After adjusting for the main variables examined, the pulsatility index measured at 3 months was positively associated with increased hazard ratios (HR) for death and cerebrovascular events [HR 9.8, 95% confidence interval (CI) 1.62-59.42], with HR increasing after adding AI@75 to the model (HR 18.8, 95% CI 2.44-145.50). In HM3 recipients, HR was significantly lower than in HMII recipients (HR 0.31, 95% CI 0.11-0.91), but the significance disappeared after adding AI@75 to the model (HR 0.33, 95% CI 0.09-1.18). CONCLUSIONS: The risk of death and cerebrovascular events in LVAD recipients is associated with increased pulsatility index in carotid arteries and potentiated by increased arterial stiffness. The same risk is attenuated by HM3 LVAD implantation, but this effect is weakened by increased arterial stiffness.
- Keywords
- Clinical events, Mechanical circulatory support, Pulsatility index,
- MeSH
- Atherosclerosis * MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Heart-Assist Devices * MeSH
- Aged MeSH
- Heart Failure * MeSH
- Treatment Outcome MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
INTRODUCTION: Changes in circulating CD34+CD45low stem cells (SC) and CD34+CD45low+KDR+ endothelial progenitor cells (EPC) may reflect pathological endothelial activation. Non-pulsatile/continuous-flow left ventricular assist devices (CF-LVAD) can enhance this process. The aim of this study was to analyse the impact of 12-month CF-LVAD treatment on SC and EPC. METHODS: We analysed changes in SC and EPC from the pre-implantation period up until 12 months after implantation over 3-month intervals in 14 patients. Data from 12 patients with heart failure (HF) and from 13 healthy volunteers were used as controls. RESULTS: Baseline EPC were significantly higher in CF-LVAD and HF patients than in healthy controls, substantially decreasing 3 months after CF-LVAD implantation and then returning to high baseline values at 12 months. CONCLUSIONS: Changes in circulating SC and EPC may reflect pathological endothelial activation after CF-LVAD implantation.
- Keywords
- continuous flow, endothelial damage, endothelial progenitor cells, mechanical circulatory support, stem cells,
- Publication type