Nejvíce citovaný článek - PubMed ID 29458696
Characterization of Respiratory Events in Obstructive Sleep Apnea Using Suprasternal Pressure Monitoring
OBJECTIVES: To determine if recording of suprasternal pressure (SSP) can classify apneas and hypopneas as reliably as respiratory inductance plethysmography (RIP) belts and to compare the two methods to classification with esophageal pressure (Pes), the reference method for assessing respiratory effort. METHODS: In addition to polysomnographic recordings that included Pes, SSP was recorded. Recordings from 32 patients (25 males, mean age 66.7 ± 15.3 years, and mean BMI 30.1 ± 4.5 kg/m2) were used to compare the classification of detected apneas and hypopneas by three methods of respiratory effort evaluation (Pes, RIP belts, and SSP). Signals were analyzed randomly and independently from each other. All recordings were analyzed according to AASM guidelines. RESULTS: Using Pes as a reference for apnea characterization, the Cohen kappa (κ) was 0.93 for SSP and 0.87 for the RIP. The sensitivity/specificity of SSP was 97.0%/96.9% for obstructive, 93.9%/98.3% for central, and 94.9%/97.9% for mixed apneas. The sensitivity/specificity of the RIP was 97.4%/91.9% for obstructive, 87.5%/97.9% for central, and 85.6%/96.6% for mixed apneas. For hypopnea characterization using the Pes as a reference, κ was 0.92 for SSP and 0.86 for the RIP. The sensitivity/specificity of SSP was 99.7%/97.6% for obstructive and 97.6%/99.7% for central. The sensitivity/specificity of the RIP was 99.8%/81.1% for obstructive and 81.1%/99.8% for central. CONCLUSIONS: These results confirm the excellent agreement in the detection of respiratory effort between SSP, RIP belts, and Pes signals. Thus, we conclude that apnea and hypopnea characterization in adults with SSP is a reliable method.
- Klíčová slova
- Polysomnography, Respiratory effort, Sleep apnea characterization, Suprasternal pressure,
- MeSH
- ezofágus patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mechanika dýchání fyziologie MeSH
- obstrukční spánková apnoe klasifikace diagnóza patofyziologie MeSH
- pletysmografie metody MeSH
- polysomnografie metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tlak MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
STUDY OBJECTIVES: Evaluation of apnea detection using a tracheal sound (TS) sensor during sleep in patients with obstructive sleep apnea. METHODS: Polysomnographic recordings of 32 patients (25 male, mean age 66.7 ± 15.3 years, and mean body mass index 30.1 ± 4.5 kg/m2) were analyzed to compare the detection of apneas by four different methods of airflow signals: oronasal thermal airflow sensor (thermistor), nasal pressure transducer (NP), respiratory inductance plethysmography (RIPsum) and TS. The four used signals were scored randomly and independently from each other according to American Academy of Sleep Medicine rules. Results of apnea detection using NP, RIPsum and TS signals were compared to those obtained by thermistor as a reference signal. RESULTS: The number of apneas detected by the thermistor was 4,167. The number of apneas detected using the NP was 5,416 (+29.97%), using the RIPsum was 2,959 (-29.71%) and using the TS was 5,019 (+20.45%). The kappa statistics (95% confidence interval) were 0.72 (0.71 to 0.74) for TS, 0.69 (0.67 to 0.70) for NP, and 0.57 (0.55 to 0.59) for RIPsum. The sensitivity/specificity (%) with respect to the thermistor were 99.23/69.27, 64.07/93.06 and 96.06/76.07 for the NP, RIPsum and TS respectively. CONCLUSIONS: With the sensor placed properly on the suprasternal notch, tracheal sounds could help detecting apneas that are underscored by the RIPsum and identify apneas that may be overscored by the NP sensor due to mouth breathing. In the absence of thermistor, TS sensors can be used for apnea detection. CLINICAL TRIAL REGISTRATION: Registry: German Clinical Trials Register (DRKS), Title: Using the tracheal sound probe of the polygraph CID102 to detect and differentiate obstructive, central, and mixed sleep apneas in patients with sleep disordered breathing, Identifier: DRKS00012795, URL: https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00012795.
- Klíčová slova
- flow measurement, home sleep apnea test, obstructive sleep apnea, polysomnography, sleep-disordered breathing, tracheal sound,
- MeSH
- lidé středního věku MeSH
- lidé MeSH
- měniče tlakové * MeSH
- nos MeSH
- pletysmografie * MeSH
- plicní ventilace * MeSH
- polysomnografie metody MeSH
- respirační zvuky * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- syndromy spánkové apnoe diagnóza MeSH
- trachea MeSH
- ústa MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH